wmbusmeters/tests/test_listen_to_all.sh

213 wiersze
7.0 KiB
Bash
Executable File

#!/bin/sh
PROG="$1"
if [ "$PROG" = "" ]
then
echo Please supply the binary to be tested as the first argument.
exit 1
fi
TEST=testoutput
LOGFILE=$TEST/logfile
LOGFILE_EXPECTED=$TEST/logfile.expected
TESTNAME="Test listen and print any meter heard in logfile"
TESTRESULT="ERROR"
mkdir -p $TEST
rm -f $LOGFILE
cat > $LOGFILE_EXPECTED <<EOF
No meters configured. Printing id:s of all telegrams heard!
Received telegram from: 12345678
manufacturer: (SON) Sontex, Switzerland (0x4dee)
device type: Warm Water (30°C-90°C) meter (0x06)
device ver: 0x3c
device driver: supercom587
Received telegram from: 11111111
manufacturer: (SON) Sontex, Switzerland (0x4dee)
device type: Water meter (0x07)
device ver: 0x3c
device driver: supercom587
Received telegram from: 12345699
manufacturer: (SEN) Sensus Metering Systems, Germany (0x4cae)
device type: Water meter (0x07)
device ver: 0x68
device driver: iperl
Received telegram from: 33225544
manufacturer: (SEN) Sensus Metering Systems, Germany (0x4cae)
device type: Water meter (0x07)
device ver: 0x68
device driver: iperl
Received telegram from: 10101010
manufacturer: (APA) Apator, Poland (0x601)
device type: Electricity meter (0x02)
device ver: 0x02
device driver: amiplus
Received telegram from: 34333231
manufacturer: (TCH) Techem Service (0x5068)
device type: Warm water (0x62)
device ver: 0x74
device driver: mkradio3
Received telegram from: 58234965
manufacturer: (TCH) Techem Service (0x5068)
device type: Heat meter (0xc3)
device ver: 0x27
device driver: vario451
Received telegram from: 11776622
manufacturer: (TCH) Techem Service (0x5068)
device type: Heat Cost Allocator (0x80)
device ver: 0x69
device driver: fhkvdataiii
Received telegram from: 88018801
manufacturer: (INE) INNOTAS Elektronik, Germany (0x25c5)
device type: Heat Cost Allocator (0x08)
device ver: 0x55
device driver: eurisii
Received telegram from: 00010204
manufacturer: (LAS) Lansen Systems, Sweden (0x3033)
device type: Smoke detector (0x1a)
device ver: 0x03
device driver: lansensm
Received telegram from: 00010204
manufacturer: (LAS) Lansen Systems, Sweden (0x3033)
device type: Smoke detector (0x1a)
device ver: 0x03
device driver: lansensm
Received telegram from: 00010203
manufacturer: (LAS) Lansen Systems, Sweden (0x3033)
device type: Room sensor (eg temperature or humidity) (0x1b)
device ver: 0x07
device driver: lansenth
Received telegram from: 00010205
manufacturer: (LAS) Lansen Systems, Sweden (0x3033)
device type: Reserved for sensors (0x1d)
device ver: 0x07
device driver: lansendw
Received telegram from: 00010205
manufacturer: (LAS) Lansen Systems, Sweden (0x3033)
device type: Reserved for sensors (0x1d)
device ver: 0x07
device driver: lansendw
Received telegram from: 00010206
manufacturer: (LAS) Lansen Systems, Sweden (0x3033)
device type: Other (0x00)
device ver: 0x14
device driver: lansenpu
Received telegram from: 11772288
manufacturer: (BMT) BMETERS, Italy (0x9b4)
device type: Room sensor (eg temperature or humidity) (0x1b)
device ver: 0x10
device driver: rfmamb
Received telegram from: 21242472
manufacturer: (SAP) Sappel (0x4c30)
device type: Oil meter (0x01)
device ver: 0xd4
device driver: izar
Received telegram from: 66290778
manufacturer: (DME) DIEHL Metering, Germany (0x11a5)
device type: Unknown (0x66)
device ver: 0x23
device driver: izar
Received telegram from: 64646464
manufacturer: (DME) DIEHL Metering, Germany (0x11a5)
device type: Water meter (0x07)
device ver: 0x70
device driver: hydrus
Received telegram from: 86868686
manufacturer: (BMT) BMETERS, Italy (0x9b4)
device type: Water meter (0x07)
device ver: 0x13
device driver: hydrodigit
Received telegram from: 72727272
manufacturer: (AXI) UAB Axis Industries, Lithuania (0x709)
device type: Water meter (0x07)
device ver: 0x10
device driver: q400
Received telegram from: 22992299
manufacturer: (EBZ) eBZ, Germany (0x145a)
device type: Radio converter (meter side) (0x37)
device ver: 0x02
device driver: ebzwmbe
Received telegram from: 77997799
manufacturer: (ESY) EasyMeter (0x1679)
device type: Radio converter (meter side) (0x37)
device ver: 0x30
device driver: esyswm
Received telegram from: 77997799
manufacturer: (ESY) EasyMeter (0x1679)
device type: Radio converter (meter side) (0x37)
device ver: 0x30
device driver: esyswm
Received telegram from: 55995599
manufacturer: (EMH) EMH metering formerly EMH Elektrizitatszahler (0x15a8)
device type: Electricity meter (0x02)
device ver: 0x02
device driver: ehzp
Received telegram from: 004444dd
manufacturer: (APT) Unknown (0x8614)
device type: Gas meter (0x03)
device ver: 0x03
device driver: apator08
Received telegram from: 74737271
manufacturer: (BMT) BMETERS, Italy (0x9b4)
device type: Water meter (0x07)
device ver: 0x05
device driver: rfmtx1
Received telegram from: 20096221
manufacturer: (DWZ) Lorenz, Germany (0x12fa)
device type: Warm Water (30°C-90°C) meter (0x06)
device ver: 0x02
device driver: waterstarm
Received telegram from: 78563412
manufacturer: (AMT) INTEGRA METERING (0x5b4)
device type: Water meter (0x07)
device ver: 0xf1
device driver: topaseskr
EOF
RES=$($PROG --logfile=$LOGFILE --t1 simulations/simulation_t1.txt 2>&1)
if [ ! "$RES" = "" ]
then
echo ERROR: $TESTNAME
echo Expected no output on stdout and stderr
echo but got------------------
echo $RES
echo ---------------------
exit 1
fi
RES=$(diff $LOGFILE $LOGFILE_EXPECTED)
if [ ! -z "$RES" ]
then
echo ERROR: $TESTNAME
echo -----------------
diff $LOGFILE $LOGFILE_EXPECTED
echo -----------------
exit 1
else
echo OK: $TESTNAME
fi
TESTNAME="Test listen and print any meter heard on stdout"
TESTRESULT="ERROR"
$PROG --t1 simulations/simulation_t1.txt 2>&1 > $LOGFILE
RES=$(diff $LOGFILE $LOGFILE_EXPECTED)
if [ ! -z "$RES" ]
then
echo ERROR: $TESTNAME
echo -----------------
diff $LOGFILE $LOGFILE_EXPECTED
echo -----------------
exit 1
else