kopia lustrzana https://github.com/weetmuts/wmbusmeters
179 wiersze
6.3 KiB
C++
179 wiersze
6.3 KiB
C++
/*
|
|
Copyright (C) 2017-2019 Fredrik Öhrström
|
|
|
|
This program is free software: you can redistribute it and/or modify
|
|
it under the terms of the GNU General Public License as published by
|
|
the Free Software Foundation, either version 3 of the License, or
|
|
(at your option) any later version.
|
|
|
|
This program is distributed in the hope that it will be useful,
|
|
but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
GNU General Public License for more details.
|
|
|
|
You should have received a copy of the GNU General Public License
|
|
along with this program. If not, see <http://www.gnu.org/licenses/>.
|
|
*/
|
|
|
|
#include"dvparser.h"
|
|
#include"meters.h"
|
|
#include"meters_common_implementation.h"
|
|
#include"wmbus.h"
|
|
#include"wmbus_utils.h"
|
|
#include"util.h"
|
|
|
|
using namespace std;
|
|
|
|
|
|
#define ERROR_CODE_VOLTAGE_PHASE_1_OVERFLOW 0x01
|
|
#define ERROR_CODE_VOLTAGE_PHASE_2_OVERFLOW 0x02
|
|
#define ERROR_CODE_VOLTAGE_PHASE_3_OVERFLOW 0x04
|
|
|
|
#define ERROR_CODE_CURRENT_PHASE_1_OVERFLOW 0x08
|
|
#define ERROR_CODE_CURRENT_PHASE_2_OVERFLOW 0x10
|
|
#define ERROR_CODE_CURRENT_PHASE_3_OVERFLOW 0x20
|
|
|
|
#define ERROR_CODE_FREQUENCY_OUT_OF_RANGE 0x40
|
|
|
|
|
|
struct MeterEM24 : public virtual ElectricityMeter, public virtual MeterCommonImplementation {
|
|
MeterEM24(WMBus *bus, MeterInfo &mi);
|
|
|
|
double totalEnergyConsumption(Unit u);
|
|
double totalEnergyProduction(Unit u);
|
|
|
|
double totalReactiveEnergyConsumption(Unit u);
|
|
double totalReactiveEnergyProduction(Unit u);
|
|
|
|
string status();
|
|
|
|
private:
|
|
void processContent(Telegram *t);
|
|
|
|
double total_true_energy_consumption_kwh_ {};
|
|
double total_true_energy_production_kwh_ {};
|
|
|
|
double total_reactive_energy_consumption_kvarh_ {};
|
|
double total_reactive_energy_production_kvarh_ {};
|
|
|
|
uint8_t error_codes_ {};
|
|
};
|
|
|
|
unique_ptr<ElectricityMeter> createEM24(WMBus *bus, MeterInfo &mi)
|
|
{
|
|
return unique_ptr<ElectricityMeter>(new MeterEM24(bus, mi));
|
|
}
|
|
|
|
MeterEM24::MeterEM24(WMBus *bus, MeterInfo &mi) :
|
|
MeterCommonImplementation(bus, mi, MeterType::EM24)
|
|
{
|
|
setExpectedELLSecurityMode(ELLSecurityMode::AES_CTR);
|
|
|
|
addLinkMode(LinkMode::C1);
|
|
|
|
addPrint("total_energy_consumption", Quantity::Energy,
|
|
[&](Unit u){ return totalEnergyConsumption(u); },
|
|
"The total energy consumption recorded by this meter.",
|
|
true, true);
|
|
|
|
addPrint("total_energy_production", Quantity::Energy,
|
|
[&](Unit u){ return totalEnergyProduction(u); },
|
|
"The total energy production recorded by this meter.",
|
|
true, true);
|
|
|
|
addPrint("total_reactive_energy_consumption", Quantity::Reactive_Energy,
|
|
[&](Unit u){ return totalReactiveEnergyConsumption(u); },
|
|
"The total reactive energy consumption recorded by this meter.",
|
|
true, true);
|
|
|
|
addPrint("total_reactive_energy_production", Quantity::Reactive_Energy,
|
|
[&](Unit u){ return totalReactiveEnergyProduction(u); },
|
|
"The total reactive energy production recorded by this meter.",
|
|
true, true);
|
|
|
|
addPrint("errors", Quantity::Text,
|
|
[&](){ return status(); },
|
|
"Any errors currently being reported.",
|
|
false, true);
|
|
}
|
|
|
|
double MeterEM24::totalEnergyConsumption(Unit u)
|
|
{
|
|
assertQuantity(u, Quantity::Energy);
|
|
return convert(total_true_energy_consumption_kwh_, Unit::KWH, u);
|
|
}
|
|
|
|
double MeterEM24::totalEnergyProduction(Unit u)
|
|
{
|
|
assertQuantity(u, Quantity::Energy);
|
|
return convert(total_true_energy_production_kwh_, Unit::KWH, u);
|
|
}
|
|
|
|
double MeterEM24::totalReactiveEnergyConsumption(Unit u)
|
|
{
|
|
assertQuantity(u, Quantity::Reactive_Energy);
|
|
return convert(total_reactive_energy_consumption_kvarh_, Unit::KVARH, u);
|
|
}
|
|
|
|
double MeterEM24::totalReactiveEnergyProduction(Unit u)
|
|
{
|
|
assertQuantity(u, Quantity::Reactive_Energy);
|
|
return convert(total_reactive_energy_production_kvarh_, Unit::KVARH, u);
|
|
}
|
|
|
|
|
|
void MeterEM24::processContent(Telegram *t)
|
|
{
|
|
int offset;
|
|
|
|
// 04 dif (32 Bit Integer/Binary Instantaneous value)
|
|
// 05 vif (Energy 10² Wh)
|
|
extractDVdouble(&t->values, "0405", &offset, &total_true_energy_consumption_kwh_);
|
|
t->addMoreExplanation(offset, " total power (%f kwh)", total_true_energy_consumption_kwh_);
|
|
|
|
// 04 dif (32 Bit Integer/Binary Instantaneous value)
|
|
// FB vif (First extension of VIF-codes)
|
|
// 82 vife (Reserved)
|
|
// 75 vife (Cold / Warm Temperature Limit 10^-2 Celsius)
|
|
extractDVdouble(&t->values, "04FB8275", &offset, &total_reactive_energy_consumption_kvarh_);
|
|
t->addMoreExplanation(offset, " total reactive power (%f kvarh)", total_reactive_energy_consumption_kvarh_);
|
|
|
|
// 04 dif (32 Bit Integer/Binary Instantaneous value)
|
|
// 85 vif (Energy 10² Wh)
|
|
// 3C vife (backward flow)
|
|
extractDVdouble(&t->values, "04853C", &offset, &total_true_energy_production_kwh_);
|
|
t->addMoreExplanation(offset, " total power (%f kwh)", total_true_energy_production_kwh_);
|
|
|
|
// 04 dif (32 Bit Integer/Binary Instantaneous value)
|
|
// FB vif (First extension of VIF-codes)
|
|
// 82 vife (Reserved)
|
|
// F5 vife (Cold / Warm Temperature Limit 10^-2 Celsius)
|
|
// 3C vife (Reserved)
|
|
extractDVdouble(&t->values, "04FB82F53C", &offset, &total_reactive_energy_production_kvarh_);
|
|
t->addMoreExplanation(offset, " total reactive power (%f kvarh)", total_reactive_energy_production_kvarh_);
|
|
|
|
// 01 dif (8 Bit Integer/Binary Instantaneous value)
|
|
// FD vif (Second extension of VIF-codes)
|
|
// 17 vife (Error flags (binary))
|
|
extractDVuint8(&t->values, "01FD17", &offset, &error_codes_);
|
|
t->addMoreExplanation(offset, " error codes (%s)", status().c_str());
|
|
}
|
|
|
|
string MeterEM24::status()
|
|
{
|
|
string s;
|
|
if (error_codes_ & ERROR_CODE_VOLTAGE_PHASE_1_OVERFLOW) s.append("V 1 OVERFLOW ");
|
|
if (error_codes_ & ERROR_CODE_VOLTAGE_PHASE_2_OVERFLOW) s.append("V 2 OVERFLOW ");
|
|
if (error_codes_ & ERROR_CODE_VOLTAGE_PHASE_3_OVERFLOW) s.append("V 3 OVERFLOW ");
|
|
if (error_codes_ & ERROR_CODE_CURRENT_PHASE_1_OVERFLOW) s.append("I 1 OVERFLOW ");
|
|
if (error_codes_ & ERROR_CODE_CURRENT_PHASE_2_OVERFLOW) s.append("I 2 OVERFLOW ");
|
|
if (error_codes_ & ERROR_CODE_CURRENT_PHASE_3_OVERFLOW) s.append("I 3 OVERFLOW ");
|
|
if (error_codes_ & ERROR_CODE_FREQUENCY_OUT_OF_RANGE) s.append("FREQUENCY ");
|
|
if (s.length() > 0) {
|
|
s.pop_back(); // Remove final space
|
|
return s;
|
|
}
|
|
return s;
|
|
}
|
|
|