#include<set>
#include"manufacturers.h"
#include"manufacturer_specificities.h"
std::set<int> diehl_manufacturers = {
MANUFACTURER_DME,
MANUFACTURER_EWT,
MANUFACTURER_HYD,
MANUFACTURER_SAP,
MANUFACTURER_SPL
};
// Diehl: is "A field" coded as version/type/serialnumber instead of standard serialnumber/version/type?
DiehlAddressTransformMethod mustTransformDiehlAddress(uchar c_field, int m_field, uchar ci_field, int tpl_cfg)
{
if (diehl_manufacturers.find(m_field) != diehl_manufacturers.end())
{
if (c_field == 0x44 || c_field == 0x46) // SND_NR / SND_IR
{
switch (ci_field) {
case 0x71: // Alarm
return DiehlAddressTransformMethod::SWAPPING; // Real Data
case 0x7A: // EN 13757-3 Application Layer (short tplh)
if (((tpl_cfg >> 8) & 0x10) == 0x10)
{
return DiehlAddressTransformMethod::SWAPPING; // Real Data
}
break; // OMS
case 0xA0: // Manufacturer specific
case 0xA1: // Manufacturer specific
case 0xA2: // Manufacturer specific
case 0xA3: // Manufacturer specific
case 0xA4: // Manufacturer specific
case 0xA5: // Manufacturer specific
case 0xA6: // Manufacturer specific
case 0xA7: // Manufacturer specific
if (m_field == MANUFACTURER_SAP)
{
return DiehlAddressTransformMethod::SAP_PRIOS; // SAP PRIOS
}
return DiehlAddressTransformMethod::SWAPPING; // PRIOS
case 0xB0: // Manufacturer specific
if (m_field == MANUFACTURER_SAP)
{
return DiehlAddressTransformMethod::SAP_PRIOS_STANDARD; // SAP PRIOS STD
}
break; // Reserved
case 0xA8: // Manufacturer specific
case 0xA9: // Manufacturer specific
case 0xAA: // Manufacturer specific
case 0xAB: // Manufacturer specific
case 0xAC: // Manufacturer specific
case 0xAD: // Manufacturer specific
case 0xAE: // Manufacturer specific
case 0xAF: // Manufacturer specific
case 0xB4: // Manufacturer specific
case 0xB5: // Manufacturer specific
case 0xB6: // Manufacturer specific
case 0xB7: // Manufacturer specific
break; // Reserved
case 0xB1: // Manufacturer specific
case 0xB2: // Manufacturer specific
case 0xB3: // Manufacturer specific
return DiehlAddressTransformMethod::SWAPPING; // PRIOS SCR
default:
break; // OMS
}
}
}
return DiehlAddressTransformMethod::NONE;
}
// Diehl: transform "A field" to make it compliant to standard
void transformDiehlAddress(std::vector<uchar>& frame, DiehlAddressTransformMethod transform_method)
{
if (transform_method == DiehlAddressTransformMethod::SWAPPING)
{
debug("(diehl) Pre-processing: swapping address field\n");
uchar version = frame[4];
uchar type = frame[5];
for (int i = 4; i < 8; i++)
{
frame[i] = frame[i+1];
}
frame[8] = version;
frame[9] = type;
}
else if (transform_method == DiehlAddressTransformMethod::SAP_PRIOS)
{
debug("(diehl) Pre-processing: setting device type to water meter for SAP PRIOS\n");
frame[8] = 0x00; // version field is used by IZAR as part of meter id on 5 bytes instead of 4
frame[9] = 0x07; // water meter
}
else if (transform_method == DiehlAddressTransformMethod::SAP_PRIOS_STANDARD)
{
warning("(diehl) Pre-processing: SAP PRIOS STANDARD transformation not implemented!\n"); // TODO
}
}