kopia lustrzana https://github.com/weetmuts/wmbusmeters
527 wiersze
17 KiB
Plaintext
527 wiersze
17 KiB
Plaintext
|
|
Added support for evo868 water meter addon module.
|
|
Added support for whe542 heat cost allocator.
|
|
|
|
Marc Kolly improved the Waterstar meter and added better error codes
|
|
and another type/version detection combo! Thanks Marc!
|
|
|
|
Janus Bo Andersen fixed the omnipower driver! Thanks Janus!
|
|
|
|
Version 1.0.4: 2020-12-05
|
|
|
|
Nikodem added support for Multical803! Thanks Nikodem!
|
|
|
|
Added a warning to be printed if an rtl_sdr dongle is found when using auto
|
|
and either rtl_sdr or rtl_wmbus cannot be found in the path at startup.
|
|
|
|
Cinemarene added support for the Techem MK Radio 4 water meter.
|
|
Thanks Cinemarene!
|
|
|
|
Mira added support for Elster V200H water meter and the Elster Merlin 868 addon.
|
|
Thanks Mira!
|
|
|
|
Version 1.0.3: 2020-11-11
|
|
|
|
Add missing files and update man page for --nodeviceexit
|
|
|
|
Version 1.0.2: 2020-11-11
|
|
|
|
Fixed bug that prevented rtlwmbus[1234] from working.
|
|
Fixed a race that in one out of 100 runs, ignored a telegram
|
|
on stdin and exited without decoding it.
|
|
|
|
Wmbusmeters now warns if you have specified /dev/ttyUSB0:im871a:c1
|
|
but there is no /dev/ttyUSB0 or if there is an amb8465 on /dev/ttyUSB0.
|
|
|
|
Added --nodeviceexit
|
|
|
|
This option will force wmbusmeters to exit if no wmbus device is found.
|
|
For example if you specify /dev/ttyUSB0:im871a:c1 and you want
|
|
wmbusmeters to fail if there is no im871a on ttyUSB0.
|
|
|
|
Added --donotprobe=/dev/ttyUSB0
|
|
|
|
(Also made sure that specifying only rtlwmbus/rtl433 will not probe
|
|
serial ttys. Specifying fully specified devices like
|
|
/dev/ttyUSB0:im871a:c1 will also not probe the other serial ttys.
|
|
Only specifying auto or a generic device type im871a that requires a
|
|
serial tty, will probe the serial devices, exluding donotprobe ones.)
|
|
|
|
Added support for the sontex868 heat cost allocator.
|
|
|
|
Jacek27 added support for the Ultrimis water meter.
|
|
Thanks Jacek27!
|
|
|
|
psxde added support for the Sensostar 2 heat meter.
|
|
Thanks psxde!
|
|
|
|
Version 1.0.1: 2020-10-26
|
|
|
|
Fix bug that prevented /dev/ttyUSB0:im871a:c1 to work.
|
|
Fix bug in install.sh that did not add wmbusmeters to the plugdev group.
|
|
|
|
Add --ignoreduplicates (ignoreduplicates=true) to ignore
|
|
any duplicates. It remembers a history of 10 telegrams.
|
|
This is useful when you have multiple dongles for covering
|
|
a larger area of reception, but sometimes telegrams arrive
|
|
at multiple dongles at the same time.
|
|
|
|
Add proper support for FlowIQ2200 water meter.
|
|
Decode two vendor values in multical603 as energy forward and returned.
|
|
Accept t1 and c1 as linkmodes for multical21 meters.
|
|
|
|
Version 1.0.0: 2020-10-25
|
|
|
|
IMPORTANT CHANGES THAT MIGHT AFFECT YOU!
|
|
|
|
** BREAKING No udev rules
|
|
|
|
Wmbusmeters new default behaviour is to never exit if no wmbus
|
|
device is found. It stays running all the time even if no
|
|
wmbus device is detected. As soon as a device is inserted
|
|
it will detect/configure and start using the device.
|
|
|
|
(When reading stdin and files, then wmbusmeters will of course exit
|
|
as soon as there is no more data or stdin is closed.)
|
|
|
|
This means that the udev rules no longer are needed and must be
|
|
removed. This will be done automatically by the install script.
|
|
|
|
** BREAKING The background rtlwmbus/rtl433 command must be wrapped in CMD(...)
|
|
|
|
If you used your own command xxx to start rtlsdr+rtlwmbus then that command
|
|
was previously supplied like this rtlwmbus:xxx
|
|
You must now type rtlwmbus:CMD(xxx)
|
|
|
|
** There is a possibility to identify some dongles with their id.
|
|
|
|
The im871a/amb8465/rtlsdr dongles have an id. This id is printed when
|
|
wmbusmeters starts using the dongle. You can later use the same id to
|
|
configure different dongles for different frequencies and link modes.
|
|
|
|
You could for example have one rtlsdr dongle with an antenna tuned for 434 MHz
|
|
and use set the id of that dongle to dongleALFA (rtl_eeprom -s dongleALFA)
|
|
likewise for 868.95 MHz. Then you can start your two dongles at the same time:
|
|
|
|
wmbusmeters rtlwmbus[dongleALFA]:434M rtlmbus[dongleBETA]:868M
|
|
|
|
The full specification of a wmbus device is this:
|
|
|
|
tty/file/stdin : type [ id ] : bps : fq : linkmodes : command
|
|
|
|
Not all values are relevant for all dongles though.
|
|
|
|
** Use stderr for logging, stdout for data.
|
|
|
|
wmbusmeters now uses STDERR as default for info/verbose/debug/trace output.
|
|
This will not affect you if you run wmbusmeters as a daemon,
|
|
but if you start wmbusmeters yourself you should check where stderr is going.
|
|
To use the old style add --usestdoutforlogging.
|
|
|
|
** New features
|
|
|
|
To list the shell envs for a meter do --listenvs=multical21
|
|
To list the fields avilable for a meter do --listfields=multical21
|
|
To list all meters do --listmeters
|
|
To search for a meter do --listmeters=water or --listmeters=multi
|
|
|
|
The wmbus device used to received the telegram and the rssi level
|
|
is part of the json, eg: "device":"rtlwmbus[1234]","rssi_dbm":-47
|
|
|
|
Version 0.9.36: 2020-09-08
|
|
|
|
Added support for detection of the proper driver
|
|
based on the manufacturer, media and version fields in the telegram.
|
|
This driver is printed when listening without specifying any meters.
|
|
The driver will be reported as unknown! for meters not yet supported by wmbusmeters.
|
|
|
|
Avandorp added support for the AquaMetro / Integra Topas Es Kr water meter.
|
|
Thanks Avandorp!
|
|
|
|
IzeCube added the Techem Compact V heatmeter!
|
|
Thanks IzeCube! Though we still need an example telegram for
|
|
testing this meter to prevent regressions. So it is currently
|
|
not as well supported as the other meters.
|
|
|
|
Version 0.9.35: 2020-08-23
|
|
|
|
Added support for alarms (shell command triggered)
|
|
and resetting of dongle when no telegrams have been received
|
|
for a preset time, or if there are communication errors
|
|
with the dongle.
|
|
|
|
Added support for the Waterstar M meter.
|
|
|
|
Bug fix for long term problem where wmbusmeters did not properly
|
|
shut down background rtl_sdr|rtl_wmbus pipeline.
|
|
|
|
Eric added support for the Multical 403. Thanks Eric!
|
|
|
|
Bibo made snapcraft fixes. The snap now builds properly! Thanks Bibo!
|
|
|
|
Version 0.9.34: 2020-07-09
|
|
|
|
Wmbusmeters should now properly handle
|
|
partially encrypted telegrams in mode 5 and 7.
|
|
|
|
The docker image now builds rtl_wmbus from the weetmuts
|
|
fork.
|
|
|
|
Bibo supplied code to auto-update the Docker hub README.
|
|
|
|
Version 0.9.33: 2020-07-01
|
|
|
|
Bibo made docker fixes. Now rtl_sdr, rtl_wmbus
|
|
and rtl_433 are part of the docker image. Thanks Bibo!
|
|
|
|
Version 0.9.32: 2020-06-30
|
|
|
|
Added support for the Lansen Smoke detector, Door/Window sensor
|
|
and Pulse counter.
|
|
|
|
The tool wmbusmeters-admin can now factory reset your amb8465 dongle.
|
|
|
|
Version 0.9.31: 2020-05-09
|
|
|
|
You can add comments in the conf and meter files.
|
|
A comment is a line that starts with #.
|
|
|
|
When using --format=fields you can now supply
|
|
--selectfields=id,total_m3 to print only the selected fields.
|
|
Run with --listfields to see all the avilable fields from a meter.
|
|
|
|
Improvements in the izar driver. Thanks Erwan!
|
|
|
|
Bug fixes in the amd8465 driver. Thanks Henry N.!
|
|
|
|
Version 0.9.30: 2020-04-22
|
|
|
|
Erwan added support for building on FreeBSD. Thanks Erwan!
|
|
|
|
Version 0.9.29: 2020-04-03
|
|
|
|
Re-add the wmbusmeters.service file so
|
|
that the daemon can be easily started without
|
|
udev rules. Check the README.
|
|
|
|
Version 0.9.28: 2020-03-08
|
|
|
|
Improved docker work, thanks Bibo!
|
|
Better shell scripts for installing and daemon mode,
|
|
in preparation for rpm packaging. Thanks Damian!
|
|
|
|
Version 0.9.27: 2020-02-26
|
|
|
|
Added support for the apator08 meter.
|
|
Fixed important bug that caused rtl_sdr to hang
|
|
when daemon was stopped/restarted.
|
|
Added support for both T1 and S1 modes for the CUL-dongle.
|
|
Added helpful messages when startup of daemon using rtl_wmbus
|
|
fails because /usr/bin/rtl_sdr or /usr/bin/rtl_wmbus are missing.
|
|
|
|
Version 0.9.26: 2020-02-07
|
|
|
|
Cinemarene added support for the Techem
|
|
FHKV Data III heat cost allocator. Thanks cinemarene!
|
|
|
|
Version 0.9.25: 2020-02-07
|
|
|
|
Fix bug i esyswm and ebzwmbe that printed zero values
|
|
for phase 2 and 3.
|
|
|
|
Version 0.9.24: 2020-02-06
|
|
|
|
Added the electricity meter eBZ wMB-E01 (ebzwmbe)
|
|
Fixed bugs with detecting the wmbus dongles.
|
|
Fixed bug in im871a driver that could
|
|
get out of sync and never receive any more telegrams.
|
|
|
|
Version 0.9.23: 2020-02-02
|
|
|
|
Added the electricity meters:
|
|
ESysWM-20 (esyswm) from EasyMeter
|
|
eHZ Generation P (ehzp) from EMH Metering
|
|
|
|
Added the water meter:
|
|
Q400 (q400) from Axis Industries.
|
|
|
|
Fixed a bug in the auto-start from udev that
|
|
prevented rtlsdr/rtlwmbus to work properly.
|
|
|
|
Version 0.9.22: 2020-01-19
|
|
|
|
Bibo added docker support. Thanks Bibo!
|
|
Checkout https://hub.docker.com/repository/docker/weetmuts/wmbusmeters
|
|
|
|
Version 0.9.21: 2020-01-19
|
|
|
|
Michal Bursa helped improve detection of a failing USB device
|
|
and added support for automatically starting multiple wmbusmeters
|
|
daemons if several dongles are inserted at the same time.
|
|
Thanks Michal!
|
|
|
|
Note! The wmbusmeters.service file is replaced with wmbusmeters@.service
|
|
and the contents of the udev file is changed. The install script
|
|
will properly install the new files and copy the old ones to ~/old.xxxx.backup files,
|
|
and tell the user how to reload the systemd and udev daemons.
|
|
|
|
Version 0.9.20: 2019-12-11
|
|
|
|
Added support for meterfilestimestamp
|
|
to get the effect of log rotation of the meter files.
|
|
|
|
Version 0.9.19: 2019-11-26
|
|
|
|
Chester4444 added support for the nanoCUL usb stick. Thanks chester4444!
|
|
Michal added a utility program (kem-import.py) to import KEM files. Thanks Michal!
|
|
Added support for the Diehl HYDRUS watermeter.
|
|
Added proper support for Multical302.
|
|
|
|
Version 0.9.18: 2019-11-10
|
|
|
|
Jacek added support for the Sappel/IZAR 868 meter. Thanks Jacek!
|
|
|
|
Version 0.9.17: 2019-11-03
|
|
|
|
Thanks to afl-fuzz I found and added
|
|
some (in retrospect pretty obvious)
|
|
missing checks to deal with
|
|
corrupted telegrams that crashed
|
|
wmbusmeters.
|
|
|
|
Now afl-fuzz does not trigger any crash
|
|
after running for a couple of minutes.
|
|
Lets fuzz more....
|
|
|
|
Version 0.9.16: 2019-11-03
|
|
|
|
Significant rewrite of serial.cc.
|
|
WMBusmeters can now specify stdin as <device>
|
|
and continuously read wmbus frames from stdin.
|
|
Either raw, or rtlwmbus formatted if stdin:rtlwmbus
|
|
is supplied as the <device>. Check the README for
|
|
more additions.
|
|
|
|
Version 0.9.15: 2019-10-20
|
|
|
|
Added Bmeter (rfmamb) and Lansen room sensors (lansenth).
|
|
Added support for the rfmrx2 dongle.
|
|
Added rawtty (eg /dev/ttyUSB0:38400) support for dongles
|
|
that only transmit raw telegrams on the serial port.
|
|
Added the ability to add static json data tailored for the meter.
|
|
|
|
Version 0.9.14: 2019-09-16
|
|
|
|
Added negative match rule for ids. You can now write:
|
|
id=78*,!7812345*,!78222222
|
|
which will match any meter whose id begins with 78
|
|
but not match any meter whose id begins with 7812345,
|
|
nor the meter with the exact id 78222222.
|
|
|
|
The order of the match rules does not matter.
|
|
|
|
Version 0.9.13: 2019-08-14
|
|
|
|
Fix bug that prevented rtl_wmbus to run inside daemon.
|
|
|
|
Version 0.9.12: 2019-08-12
|
|
|
|
Added experimental detection for apator162 where the total water consumption
|
|
is located within the proprietary data.
|
|
|
|
Version 0.9.11: 2019-06-20
|
|
|
|
Added --meterfilesnaming=(name|id|name-id)
|
|
to choose the file name written meter file.
|
|
|
|
Naming using id or name-id is necessary when a meter
|
|
specification listens to many different meters using id
|
|
wildcards.
|
|
|
|
Version 0.9.10: 2019-06-13
|
|
|
|
Update logrotate to trigger HUP when rotating log files.
|
|
This will re-initialize the serial connection to the usb dongle
|
|
and reload the config files as well.
|
|
|
|
Added reload command to systemctl.
|
|
|
|
Version 0.9.9: 2019-06-11
|
|
|
|
Added support for the signal HUP to trigger wmbusmeters(d)
|
|
to reload config files.
|
|
|
|
Added significantly better tracking of listening modes (C1,T1,S1 etc)
|
|
and notify the user if the wmbusmeters configuration would not hear
|
|
certain meters specified.
|
|
|
|
The apator162 meter can send either on c1 or t1. Thus if you have
|
|
an imst871a dongle that can only listen on one of c1/t1, then
|
|
you have to specify which link mode you expect the meter to use.
|
|
You do that by suffixing the meter type with the link mode, like
|
|
this: `apator162:c1`
|
|
|
|
If you do not do this, then wmbusmeters will assume that it must
|
|
listen to both c1 and t1 at the same time. Which might
|
|
be fine for amd8465 and rtlwmbus dongles, but not for imst871a.
|
|
|
|
Version 0.9.8: 2019-05-22
|
|
|
|
Added support for the EurisII heat cost allocator from Innotas.
|
|
|
|
Version 0.9.7: 2019-05-04
|
|
|
|
FeatureExpert added support for the Vario 451 heat meter. Thanks FeatureExpert!
|
|
|
|
New feature: --addconversions=GJ,L
|
|
|
|
This feature required a major rewrite of how meters print their data.
|
|
When the new option --addconversion=<unit> is used, then
|
|
any meter that outputs a compatible unit (like kWh) will have
|
|
the additional unit (like GJ) also added to to the json.
|
|
|
|
So if there is a total_energy_consumption_kwh in the json,
|
|
there will now also be a total_energy_consumption_gj
|
|
|
|
For the human readable output and the fields output, the kWh is replaced with GJ.
|
|
|
|
ATTENTION! change in json keys!
|
|
|
|
Some untyped json field names, like "flow_temperature":10 had to
|
|
change name to "flow_temperature_c":0 (so that if --addconversions=F
|
|
is used, then "flow_temperature_f":32 will be added.)
|
|
|
|
Version 0.9.6: 2019-04-27
|
|
|
|
Added support for the MK Radio 3 water meter. Thanks FeatureExpert!
|
|
|
|
Version 0.9.5: 2019-04-26
|
|
|
|
Improved install/uninstall scripts. Thanks Bibo!
|
|
|
|
Fixed wrong default sample frequency for rtl_wmbus. Thanks inc90!
|
|
|
|
Version 0.9.4: 2019-04-03
|
|
|
|
The device auto can now detect an rtlsdr dongle and start
|
|
rtl_sdr|rtl_wmbus properly. It can only detecht the rtlsdr
|
|
dongle if the new udev rule has been installed, which will
|
|
create the symlink /dev/rtlsdr when the dongle is inserted.
|
|
|
|
Added the meter vendor Echelon to the generic amiplus meter type.
|
|
(The Echelon meter seems to be a standard electricity meter with a
|
|
wmbus addon sourced from Develco.)
|
|
|
|
Version 0.9.3: 2019-03-20
|
|
|
|
Added initial support for the generic Tauron Amiplus electricity meter type (amiplus).
|
|
This is actually a generic meter type, that will match the meter vendors
|
|
that provide meters under the Amiplus brand to Taurn. The first vendor to
|
|
be supported is from Apator.
|
|
|
|
Added support for the at-wmbus-16-2 snap on meter (apator162).
|
|
Unfortunately it uses a vendor specific protocol,
|
|
that is merely wrapped inside a wmbus telegram. Lets hope
|
|
the offset to the consumption is stable between
|
|
meters of this type.
|
|
|
|
Verison 0.9.2: 2019-03-12
|
|
|
|
Add max_flow to the iperl meter. This is based
|
|
on a guess that the flow value is actually the max
|
|
flow.
|
|
|
|
Note! Since max flow was added to iperl, there is an extra
|
|
column in the human output and --format=fields output.
|
|
There is also "max_flow_m3h"="123" in the json output, but that does not
|
|
affect existing code depending on json.
|
|
|
|
Verison 0.9.1: 2019-03-05
|
|
|
|
Added support for listening to multiple meters
|
|
with the same key (or no key). Simple use '*'
|
|
as meter id, or make a comma separated list.
|
|
|
|
Added experimental support for listening to
|
|
--n1a to --n1f and an imst dongle. Might not work.
|
|
|
|
Version 0.9.0: 2019-02-26
|
|
|
|
Reading the meter settings from config files
|
|
in /etc is now supported.
|
|
Running wmbusmeters as daemon is now supported.
|
|
Using rtl_wmbus to receive wmbus messages from
|
|
rtl_sdr is work in progress.
|
|
Updated README
|
|
Updated some command line options robot is now format.
|
|
Listening to qcaloric now seems to work.
|
|
Added support for MacOSX.
|
|
|
|
Version 0.8.4: 2019-02-23
|
|
|
|
Add config files support and daemon mode.
|
|
|
|
Version 0.8.3: 2019-02-17
|
|
|
|
Add experimental support for qcaloric.
|
|
|
|
Version 0.8.2: 2019-01-27
|
|
|
|
Properly supports short C1 frames after it has received a long frame.
|
|
(Ie the format signature hash is properly calculated and used.)
|
|
Now properly extracts temperature from short frames!
|
|
Added support for Multical21 meters with max flow configuration.
|
|
|
|
Note! Since max flow was added to multical21, there is an extra
|
|
column in the human output and --format=fields output.
|
|
There is also "max_flow_m3h"="123" in the json output, but that does not
|
|
affect existing code depending on json.
|
|
|
|
Version 0.8.1: 2019-01-04
|
|
|
|
Fixed memory leak in shell invocation.
|
|
Improved dvparser to properly handle the supercom587 telegrams.
|
|
(It still does not extract all the data, but the data is properly parsed and chunked.)
|
|
Added address sanitizer to debug build.
|
|
Added static analysis check.sh.
|
|
|
|
Version 0.8: 2018-11-29
|
|
|
|
Multical21 now reports flow temperature and external temperature.
|
|
|
|
Version 0.7: 2018-11-23
|
|
|
|
David Mallon contributed the iPerl water meter! Thanks David!
|
|
|
|
Version 0.6: 2018-11-02
|
|
|
|
Added --shell command to invoke for example: mosquitto to send an MQTT message
|
|
or psql to insert received data into a database.
|
|
|
|
Added proper T1 telegram support. First meter to use T1 is supercom587.
|
|
A large part of the supercom587 message is not yet properly decoded.
|
|
However the important part, the total consumption, is correct.
|
|
|
|
Version 0.5:
|
|
|
|
Added difvif parser to extract as much as possible automatically
|
|
from the the telegram.
|
|
|
|
Added initial support for Omnipower electricity meter.
|
|
|
|
Version 0.4:
|
|
|
|
Added initial support for heat energy meter Multical302.
|
|
Restructured to source to more easily support multiple meters.
|
|
|
|
ATTENTION! There is a difference in the command line interface.
|
|
You must now proved the meter type. Thus for each meter you
|
|
supply quadruplets instead of triplets.
|
|
|
|
Version 0.3:
|
|
|
|
Added support for wmbus USB receiver Amber AMB8465.
|
|
|
|
Version 0.2:
|
|
|
|