kopia lustrzana https://github.com/weetmuts/wmbusmeters
228 wiersze
9.8 KiB
C++
228 wiersze
9.8 KiB
C++
/*
|
|
Copyright (C) 2020-2022 Patrick Schwarz (gpl-3.0-or-later)
|
|
Copyright (C) 2022 Fredrik Öhrström (gpl-3.0-or-later)
|
|
|
|
This program is free software: you can redistribute it and/or modify
|
|
it under the terms of the GNU General Public License as published by
|
|
the Free Software Foundation, either version 3 of the License, or
|
|
(at your option) any later version.
|
|
|
|
This program is distributed in the hope that it will be useful,
|
|
but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
GNU General Public License for more details.
|
|
|
|
You should have received a copy of the GNU General Public License
|
|
along with this program. If not, see <http://www.gnu.org/licenses/>.
|
|
*/
|
|
|
|
#include"meters_common_implementation.h"
|
|
|
|
namespace
|
|
{
|
|
struct Driver : public virtual MeterCommonImplementation {
|
|
Driver(MeterInfo &mi, DriverInfo &di);
|
|
};
|
|
|
|
static bool ok = registerDriver([](DriverInfo&di)
|
|
{
|
|
di.setName("sensostar");
|
|
di.setDefaultFields("name,id,total_kwh,total_water_m3,current_status,reporting_date,energy_consumption_at_reporting_date_kwh,timestamp");
|
|
di.setMeterType(MeterType::HeatMeter);
|
|
di.addLinkMode(LinkMode::C1);
|
|
di.addLinkMode(LinkMode::T1);
|
|
di.addDetection(MANUFACTURER_EFE, 0x04, 0x00);
|
|
di.setConstructor([](MeterInfo& mi, DriverInfo& di){ return shared_ptr<Meter>(new Driver(mi, di)); });
|
|
});
|
|
|
|
Driver::Driver(MeterInfo &mi, DriverInfo &di) : MeterCommonImplementation(mi, di)
|
|
{
|
|
addStringFieldWithExtractor(
|
|
"meter_timestamp",
|
|
"Date time for this reading.",
|
|
DEFAULT_PRINT_PROPERTIES,
|
|
FieldMatcher::build()
|
|
.set(MeasurementType::Instantaneous)
|
|
.set(VIFRange::DateTime)
|
|
);
|
|
|
|
addNumericFieldWithExtractor(
|
|
"total",
|
|
"The total energy consumption recorded by this meter.",
|
|
DEFAULT_PRINT_PROPERTIES,
|
|
Quantity::Energy,
|
|
VifScaling::Auto,
|
|
FieldMatcher::build()
|
|
.set(MeasurementType::Instantaneous)
|
|
.set(VIFRange::AnyEnergyVIF)
|
|
);
|
|
|
|
addNumericFieldWithExtractor(
|
|
"power",
|
|
"The active power consumption.",
|
|
DEFAULT_PRINT_PROPERTIES,
|
|
Quantity::Power,
|
|
VifScaling::Auto,
|
|
FieldMatcher::build()
|
|
.set(MeasurementType::Instantaneous)
|
|
.set(VIFRange::AnyPowerVIF)
|
|
);
|
|
|
|
addNumericFieldWithExtractor(
|
|
"power_max",
|
|
"The maximum power consumption over ?period?.",
|
|
DEFAULT_PRINT_PROPERTIES,
|
|
Quantity::Power,
|
|
VifScaling::Auto,
|
|
FieldMatcher::build()
|
|
.set(MeasurementType::Maximum)
|
|
.set(VIFRange::AnyPowerVIF)
|
|
);
|
|
|
|
addNumericFieldWithExtractor(
|
|
"flow_water",
|
|
"The flow of water.",
|
|
DEFAULT_PRINT_PROPERTIES,
|
|
Quantity::Flow,
|
|
VifScaling::Auto,
|
|
FieldMatcher::build()
|
|
.set(MeasurementType::Instantaneous)
|
|
.set(VIFRange::VolumeFlow)
|
|
);
|
|
|
|
addNumericFieldWithExtractor(
|
|
"flow_water_max",
|
|
"The maximum forward flow of water over a ?period?.",
|
|
DEFAULT_PRINT_PROPERTIES,
|
|
Quantity::Flow,
|
|
VifScaling::Auto,
|
|
FieldMatcher::build()
|
|
.set(MeasurementType::Maximum)
|
|
.set(VIFRange::VolumeFlow)
|
|
);
|
|
|
|
addNumericFieldWithExtractor(
|
|
"forward",
|
|
"The forward temperature of the water.",
|
|
DEFAULT_PRINT_PROPERTIES,
|
|
Quantity::Temperature,
|
|
VifScaling::Auto,
|
|
FieldMatcher::build()
|
|
.set(MeasurementType::Instantaneous)
|
|
.set(VIFRange::FlowTemperature)
|
|
);
|
|
|
|
addNumericFieldWithExtractor(
|
|
"return",
|
|
"The return temperature of the water.",
|
|
DEFAULT_PRINT_PROPERTIES,
|
|
Quantity::Temperature,
|
|
VifScaling::Auto,
|
|
FieldMatcher::build()
|
|
.set(MeasurementType::Instantaneous)
|
|
.set(VIFRange::ReturnTemperature)
|
|
);
|
|
|
|
addNumericFieldWithExtractor(
|
|
"difference",
|
|
"The temperature difference forward-return for the water.",
|
|
DEFAULT_PRINT_PROPERTIES,
|
|
Quantity::Temperature,
|
|
VifScaling::AutoSigned,
|
|
FieldMatcher::build()
|
|
.set(MeasurementType::Instantaneous)
|
|
.set(VIFRange::TemperatureDifference)
|
|
);
|
|
|
|
addNumericFieldWithExtractor(
|
|
"total_water",
|
|
"The total amount of water that has passed through this meter.",
|
|
DEFAULT_PRINT_PROPERTIES,
|
|
Quantity::Volume,
|
|
VifScaling::Auto,
|
|
FieldMatcher::build()
|
|
.set(MeasurementType::Instantaneous)
|
|
.set(VIFRange::Volume)
|
|
);
|
|
|
|
addStringFieldWithExtractorAndLookup(
|
|
"current_status",
|
|
"Status and error flags.",
|
|
DEFAULT_PRINT_PROPERTIES,
|
|
FieldMatcher::build()
|
|
.set(VIFRange::ErrorFlags),
|
|
{
|
|
{
|
|
{
|
|
"ERROR_FLAGS",
|
|
Translate::Type::BitToString,
|
|
AlwaysTrigger, MaskBits(0xff),
|
|
"OK",
|
|
{
|
|
// based on information published here: https://www.engelmann.de/wp-content/uploads/2022/10/1080621004_2022-10-12_BA_S3_ES_Comm_en.pdf
|
|
{ 0x01 , "ERROR_TEMP_SENSOR_1_CABLE_BREAK" },
|
|
{ 0x02 , "ERROR_TEMP_SENSOR_1_SHORT_CIRCUIT" },
|
|
{ 0x04 , "ERROR_TEMP_SENSOR_2_CABLE_BREAK" },
|
|
{ 0x08 , "ERROR_TEMP_SENSOR_2_SHORT_CIRCUIT" },
|
|
{ 0x10 , "ERROR_FLOW_MEASUREMENT_SYSTEM_ERROR" },
|
|
{ 0x20 , "ERROR_ELECTRONICS_DEFECT" },
|
|
{ 0x40 , "OK_INSTRUMENT_RESET" },
|
|
{ 0x80 , "OK_BATTERY_LOW" }
|
|
}
|
|
},
|
|
},
|
|
});
|
|
|
|
addStringFieldWithExtractor(
|
|
"reporting_date",
|
|
"The reporting date of the last billing period.",
|
|
DEFAULT_PRINT_PROPERTIES,
|
|
FieldMatcher::build()
|
|
.set(MeasurementType::Instantaneous)
|
|
.set(VIFRange::Date)
|
|
.set(StorageNr(1))
|
|
);
|
|
|
|
addNumericFieldWithExtractor(
|
|
"energy_consumption_at_reporting_date",
|
|
"The energy consumption at the last billing period date.",
|
|
DEFAULT_PRINT_PROPERTIES,
|
|
Quantity::Energy,
|
|
VifScaling::Auto,
|
|
FieldMatcher::build()
|
|
.set(MeasurementType::Instantaneous)
|
|
.set(VIFRange::AnyEnergyVIF)
|
|
.set(StorageNr(1))
|
|
);
|
|
|
|
for (int i=1; i<=15; ++i)
|
|
{
|
|
string name, info;
|
|
strprintf(&name, "consumption_%d_months_ago", i);
|
|
strprintf(&info, "Energy consumption %d month(s) ago.", i);
|
|
addNumericFieldWithExtractor(
|
|
name,
|
|
info,
|
|
DEFAULT_PRINT_PROPERTIES,
|
|
Quantity::Energy,
|
|
VifScaling::Auto,
|
|
FieldMatcher::build()
|
|
.set(MeasurementType::Instantaneous)
|
|
.set(VIFRange::AnyEnergyVIF)
|
|
.set(StorageNr(i)));
|
|
}
|
|
}
|
|
}
|
|
|
|
// Test: Heat sensostar 20480057 NOKEY
|
|
// Comment:
|
|
// telegram=|68B3B36808007257004820c51400046c100000047839803801040600000000041300000000042B00000000142B00000000043B00000000143B00000000025B1400025f15000261daff02235c00046d2c2ddc24440600000000441300000000426c000001fd171003fd0c05000084200600000000c420060000000084300600000000c430060000000084401300000000c44013000000008480401300000000c48040130000000084c0401300000000c4c0401300000000a216|
|
|
// {"media":"heat","meter":"sensostar","name":"Heat","id":"20480057","meter_timestamp":"2022-04-28 13:44","total_kwh":0,"power_kw":0,"power_max_kw":0,"flow_water_m3h":0,"flow_water_max_m3h":0,"forward_c":20,"return_c":21,"difference_c":-0.38,"total_water_m3":0,"current_status":"ERROR_FLOW_MEASUREMENT_SYSTEM_ERROR","reporting_date":"2000-00-00","energy_consumption_at_reporting_date_kwh":0,"consumption_1_months_ago_kwh":0,"timestamp":"1111-11-11T11:11:11Z"}
|
|
// |Heat;20480057;0;0;ERROR_FLOW_MEASUREMENT_SYSTEM_ERROR;2000-00-00;0;1111-11-11 11:11.11
|
|
|
|
// Test: WMZ sensostar 02752560 NOKEY
|
|
// Comment: from "Sensostar U"
|
|
//telegram=a444c5146025750200047ac20000202f2f046d2e26c62a040643160000041310f0050001fd1700426cbf2c4406570e00008401061f160000840206f6150000840306f5150000840406f3150000840506ea150000840606bf1500008407065214000084080692120000840906c5100000840a06570e0000840b06ca0b0000840c06da090000840d06ca080000840e06c8080000840f06c608000003fd0c05010002fd0b2111
|
|
//{"media":"heat","meter":"sensostar","name":"WMZ","id":"02752560","meter_timestamp":"2022-10-06 06:46","total_kwh":5699,"total_water_m3":389.136,"current_status":"OK","reporting_date":"2021-12-31","energy_consumption_at_reporting_date_kwh":3671,"consumption_1_months_ago_kwh":5663,"consumption_2_months_ago_kwh":5622,"consumption_3_months_ago_kwh":5621,"consumption_4_months_ago_kwh":5619,"consumption_5_months_ago_kwh":5610,"consumption_6_months_ago_kwh":5567,"consumption_7_months_ago_kwh":5202,"consumption_8_months_ago_kwh":4754,"consumption_9_months_ago_kwh":4293,"consumption_10_months_ago_kwh":3671,"consumption_11_months_ago_kwh":3018,"consumption_12_months_ago_kwh":2522,"consumption_13_months_ago_kwh":2250,"consumption_14_months_ago_kwh":2248,"consumption_15_months_ago_kwh":2246,"timestamp":"1111-11-11 11:11.11"}
|
|
//WMZ;02752560;5699;389.136000;OK;1111-11-11 11:11.11
|