kopia lustrzana https://github.com/weetmuts/wmbusmeters
210 wiersze
8.5 KiB
C++
210 wiersze
8.5 KiB
C++
/*
|
|
Copyright (C) 2021-2022 Fredrik Öhrström (gpl-3.0-or-later)
|
|
|
|
This program is free software: you can redistribute it and/or modify
|
|
it under the terms of the GNU General Public License as published by
|
|
the Free Software Foundation, either version 3 of the License, or
|
|
(at your option) any later version.
|
|
|
|
This program is distributed in the hope that it will be useful,
|
|
but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
GNU General Public License for more details.
|
|
|
|
You should have received a copy of the GNU General Public License
|
|
along with this program. If not, see <http://www.gnu.org/licenses/>.
|
|
*/
|
|
|
|
#include"meters_common_implementation.h"
|
|
|
|
namespace
|
|
{
|
|
struct Driver : public virtual MeterCommonImplementation
|
|
{
|
|
Driver(MeterInfo &mi, DriverInfo &di);
|
|
};
|
|
|
|
static bool ok = registerDriver([](DriverInfo&di)
|
|
{
|
|
di.setName("lse_07_17");
|
|
di.setDefaultFields("name,id,total_m3,due_date_m3,due_date,error_code,error_date,device_date_time,timestamp");
|
|
di.setMeterType(MeterType::WaterMeter);
|
|
di.addLinkMode(LinkMode::S1);
|
|
di.addDetection(MANUFACTURER_LSE, 0x06, 0x18);
|
|
di.addDetection(MANUFACTURER_LSE, 0x07, 0x18);
|
|
di.addDetection(MANUFACTURER_LSE, 0x07, 0x16);
|
|
di.addDetection(MANUFACTURER_LSE, 0x07, 0x17);
|
|
di.setConstructor([](MeterInfo& mi, DriverInfo& di){ return shared_ptr<Meter>(new Driver(mi, di)); });
|
|
});
|
|
|
|
Driver::Driver(MeterInfo &mi, DriverInfo &di) : MeterCommonImplementation(mi, di)
|
|
{
|
|
addNumericFieldWithExtractor(
|
|
"total",
|
|
"The total water consumption recorded by this meter.",
|
|
DEFAULT_PRINT_PROPERTIES,
|
|
Quantity::Volume,
|
|
VifScaling::Auto,
|
|
FieldMatcher::build()
|
|
.set(MeasurementType::Instantaneous)
|
|
.set(VIFRange::Volume)
|
|
);
|
|
|
|
addNumericFieldWithExtractor(
|
|
"due_date",
|
|
"The water consumption at the due date.",
|
|
DEFAULT_PRINT_PROPERTIES,
|
|
Quantity::Volume,
|
|
VifScaling::Auto,
|
|
FieldMatcher::build()
|
|
.set(MeasurementType::Instantaneous)
|
|
.set(VIFRange::Volume)
|
|
.set(StorageNr(1))
|
|
);
|
|
|
|
addStringFieldWithExtractor(
|
|
"due_date",
|
|
"The due date configured on the meter.",
|
|
DEFAULT_PRINT_PROPERTIES,
|
|
FieldMatcher::build()
|
|
.set(MeasurementType::Instantaneous)
|
|
.set(VIFRange::Date)
|
|
.set(StorageNr(1))
|
|
);
|
|
|
|
addNumericFieldWithExtractor(
|
|
"what_date",
|
|
"The water consumption at the what date?",
|
|
DEFAULT_PRINT_PROPERTIES,
|
|
Quantity::Volume,
|
|
VifScaling::Auto,
|
|
FieldMatcher::build()
|
|
.set(MeasurementType::Instantaneous)
|
|
.set(VIFRange::Volume)
|
|
.set(StorageNr(8))
|
|
);
|
|
|
|
addStringFieldWithExtractor(
|
|
"what_date",
|
|
"The what date?",
|
|
DEFAULT_PRINT_PROPERTIES,
|
|
FieldMatcher::build()
|
|
.set(MeasurementType::Instantaneous)
|
|
.set(VIFRange::Date)
|
|
.set(StorageNr(8))
|
|
);
|
|
|
|
addStringFieldWithExtractorAndLookup(
|
|
"error_code",
|
|
"Error code of the Meter, 0 means no error.",
|
|
DEFAULT_PRINT_PROPERTIES,
|
|
FieldMatcher::build()
|
|
.set(DifVifKey("02BB56")
|
|
),
|
|
{
|
|
{
|
|
{
|
|
"ERROR_FLAGS",
|
|
Translate::Type::BitToString,
|
|
AlwaysTrigger, MaskBits(0xffff),
|
|
"OK",
|
|
{
|
|
// { 0x01, "?" },
|
|
}
|
|
},
|
|
},
|
|
});
|
|
|
|
addStringFieldWithExtractor(
|
|
"error_date",
|
|
"The date the error occurred at. If no error, reads 2127-15-31 (FFFF).",
|
|
DEFAULT_PRINT_PROPERTIES,
|
|
FieldMatcher::build()
|
|
.set(MeasurementType::AtError)
|
|
.set(VIFRange::Date)
|
|
);
|
|
|
|
addStringFieldWithExtractor(
|
|
"device_date_time",
|
|
"Date when measurement was recorded.",
|
|
DEFAULT_PRINT_PROPERTIES,
|
|
FieldMatcher::build()
|
|
.set(MeasurementType::Instantaneous)
|
|
.set(VIFRange::DateTime)
|
|
);
|
|
|
|
addStringFieldWithExtractor(
|
|
"meter_version",
|
|
"Meter model/version.",
|
|
DEFAULT_PRINT_PROPERTIES,
|
|
FieldMatcher::build()
|
|
.set(MeasurementType::Instantaneous)
|
|
.set(VIFRange::ModelVersion)
|
|
);
|
|
}
|
|
}
|
|
|
|
/*
|
|
The following telegram corresponds to the Qundis QWater5.5 cold water meters I have here.
|
|
From the device display it states that it is set to S-mode operation, sending a telegram
|
|
every 4 h.
|
|
Another option of this device is the C mode operation, sending telegrams every
|
|
7.5 s.
|
|
|
|
Even though my meters are definitely Qundis QWater5.5, the meters do not identify with
|
|
manufacturer code QDS but with LSE.
|
|
|
|
(lse_07_17) 0f: 0C dif (8 digit BCD Instantaneous value)
|
|
(lse_07_17) 10: 13 vif (Volume l)
|
|
(lse_07_17) 11: * 04400100 total consumption (14.004000 m3)
|
|
(lse_07_17) 15: 4C dif (8 digit BCD Instantaneous value storagenr=1)
|
|
(lse_07_17) 16: 13 vif (Volume l)
|
|
(lse_07_17) 17: * 40620000 due date consumption (6.240000 m3)
|
|
(lse_07_17) 1b: 42 dif (16 Bit Integer/Binary Instantaneous value storagenr=1)
|
|
(lse_07_17) 1c: 6C vif (Date type G)
|
|
(lse_07_17) 1d: * 9F2C due date (2020-12-31)
|
|
(lse_07_17) 1f: 02 dif (16 Bit Integer/Binary Instantaneous value)
|
|
(lse_07_17) 20: BB vif (Volume flow l/h)
|
|
(lse_07_17) 21: 56 vife (duration of limit exceed last lower is 2)
|
|
(lse_07_17) 22: * 0000 error code (0)
|
|
(lse_07_17) 24: 32 dif (16 Bit Integer/Binary Value during error state)
|
|
(lse_07_17) 25: 6C vif (Date type G)
|
|
(lse_07_17) 26: * FFFF error date (2127-15-31)
|
|
(lse_07_17) 28: 04 dif (32 Bit Integer/Binary Instantaneous value)
|
|
(lse_07_17) 29: 6D vif (Date and time type)
|
|
(lse_07_17) 2a: * 180DA924 device datetime (2021-04-09 13:24)
|
|
|
|
if (findKey(MeasurementType::Instantaneous, VIFRange::DateTime, 0, 0, &key, &t->dv_entries)) {
|
|
struct tm datetime;
|
|
extractDVdate(&t->dv_entries, key, &offset, &datetime);
|
|
device_date_time_ = strdatetime(&datetime);
|
|
t->addMoreExplanation(offset, " device datetime (%s)", device_date_time_.c_str());
|
|
}
|
|
// How do the following error codes on the display map to the code in the telegram?
|
|
// According to the datasheet, these errors can appear on the display:
|
|
// LEAC Leak in the system (no associated error code)
|
|
// 0 Negative direction of flow.
|
|
// 2 Operating hours expired.
|
|
// 3 Hardware error.
|
|
// 4 Permanently stored error.
|
|
// b Communication via OPTO too often per month.
|
|
// c Communication via M-Bus too often per month.
|
|
// d Flow too high.
|
|
// f Device was without voltage supply briefly. All parameter settings are lost.
|
|
*/
|
|
|
|
|
|
// Test: Water lse_07_17 13963399 NOKEY
|
|
|
|
// telegram=|244465329933961318067AE1000000_8C04130070000082046CBE2B01FD0C11046D010CA22C|
|
|
// {"media":"warm water","meter":"lse_07_17","name":"Water","id":"13963399","what_date_m3":7,"what_date":"2021-11-30","device_date_time":"2021-12-02 12:01","meter_version":"11","timestamp":"1111-11-11T11:11:11Z"}
|
|
// |Water;13963399;null;null;null;null;null;2021-12-02 12:01;1111-11-11 11:11.11
|
|
|
|
// telegram=|2A4465329933961318067AD8800000_8C04130070000082046CBE2B01FD0C11046D1800A12C02FDAC7E9B2E|
|
|
// {"media":"warm water","meter":"lse_07_17","name":"Water","id":"13963399","what_date_m3":7,"what_date":"2021-11-30","device_date_time":"2021-12-01 00:24","meter_version":"11","timestamp":"1111-11-11T11:11:11Z"}
|
|
// |Water;13963399;null;null;null;null;null;2021-12-01 00:24;1111-11-11 11:11.11
|
|
|
|
// telegram=|2D4465329933961318067ADA000000_0C13567100004C1300000000426CFFFF02BB560000326CFFFF046D2307A12C|
|
|
// {"media":"warm water","meter":"lse_07_17","name":"Water","id":"13963399","total_m3":7.156,"due_date_m3":0,"due_date":"2127-15-31","what_date_m3":7,"what_date":"2021-11-30","error_code":"OK","error_date":"2127-15-31","device_date_time":"2021-12-01 07:35","meter_version":"11","timestamp":"1111-11-11T11:11:11Z"}
|
|
// |Water;13963399;7.156;0;2127-15-31;OK;2127-15-31;2021-12-01 07:35;1111-11-11 11:11.11
|