wmbusmeters/src/meters.h

488 wiersze
19 KiB
C++

/*
Copyright (C) 2017-2022 Fredrik Öhrström (gpl-3.0-or-later)
This program is free software: you can redistribute it and/or modify
it under the terms of the GNU General Public License as published by
the Free Software Foundation, either version 3 of the License, or
(at your option) any later version.
This program is distributed in the hope that it will be useful,
but WITHOUT ANY WARRANTY; without even the implied warranty of
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
GNU General Public License for more details.
You should have received a copy of the GNU General Public License
along with this program. If not, see <http://www.gnu.org/licenses/>.
*/
#ifndef METER_H_
#define METER_H_
#include"address.h"
#include"dvparser.h"
#include"formula.h"
#include"util.h"
#include"units.h"
#include"translatebits.h"
#include"xmq.h"
#include"wmbus.h"
#include<assert.h>
#include<functional>
#include<numeric>
#include<string>
#include<vector>
#define LIST_OF_METER_TYPES \
X(AutoMeter) \
X(UnknownMeter) \
X(DoorWindowDetector) \
X(ElectricityMeter) \
X(GasMeter) \
X(HeatCoolingMeter) \
X(HeatCostAllocationMeter) \
X(HeatMeter) \
X(PressureSensor) \
X(PulseCounter) \
X(Repeater) \
X(SmokeDetector) \
X(TempHygroMeter) \
X(WaterMeter) \
enum class MeterType {
#define X(name) name,
LIST_OF_METER_TYPES
#undef X
};
struct DriverName
{
DriverName() {};
DriverName(string s) : name_(s) {};
const string &str() const { return name_; }
bool operator==(const DriverName &dn) const { return name_ == dn.name_; }
private:
string name_;
};
// Return a list of matching drivers, like: multical21
void detectMeterDrivers(int manufacturer, int media, int version, std::vector<std::string> *drivers);
// When entering the driver, check that the telegram is indeed known to be
// compatible with the driver(type), if not then print a warning.
bool isMeterDriverValid(DriverName driver_name, int manufacturer, int media, int version);
// For an unknown telegram, when analyzing check if the media type is reasonable in relation to the driver.
// Ie. do not try to decode a door sensor telegram with a water meter driver.
bool isMeterDriverReasonableForMedia(string driver_name, int media);
struct MeterInfo;
bool isValidKey(const string& key, MeterInfo &mt);
using namespace std;
struct MeterInfo
{
string bus; // The bus used to communicate with this meter. A device like /dev/ttyUSB0 or an alias like BUS1.
// A bus can be an mbus or a wmbus dongle.
// The bus can be the empty string, which means that it will fallback to the first defined bus.
string name; // User specified name of this (group of) meters.
DriverName driver_name; // Will replace MeterDriver.
string extras; // Extra driver specific settings.
vector<AddressExpression> address_expressions; // Match expressions for ids.
IdentityMode identity_mode {}; // How to group telegram content into objects with state. Default is by id.
string key; // Decryption key.
LinkModeSet link_modes;
int bps {}; // For mbus communication you need to know the baud rate.
vector<string> shells;
vector<string> meter_shells;
vector<string> extra_constant_fields; // Additional static fields that are added to each message.
vector<string> extra_calculated_fields; // Additional field calculated using formulas.
vector<string> selected_fields; // Usually set to the default fields, but can be override in meter config.
// If this is a meter that needs to be polled.
int poll_interval; // Poll every x seconds.
MeterInfo()
{
}
string str();
DriverName driverName();
MeterInfo(string b, string n, string e, vector<AddressExpression> aes, string k, LinkModeSet lms, int baud, vector<string> &s, vector<string> &ms, vector<string> &j, vector<string> &calcfs)
{
bus = b;
name = n;
extras = e,
address_expressions = aes;
key = k;
shells = s;
meter_shells = ms;
extra_constant_fields = j;
extra_calculated_fields = calcfs;
link_modes = lms;
bps = baud;
}
void clear()
{
bus = "";
name = "";
address_expressions.clear();
key = "";
shells.clear();
meter_shells.clear();
extra_constant_fields.clear();
extra_calculated_fields.clear();
link_modes.clear();
bps = 0;
}
bool parse(string name, string driver, string id, string key);
bool usesPolling();
};
/////////////////////////////////////////////////////////////////////////////////////////////////////////////
//
// Dynamic loading of drivers based on the driver info.
//
////////////////////////////////////////////////////////////////////////////////////////////////////////////
struct DriverDetect
{
uint16_t mfct;
uchar type;
uchar version;
};
struct DriverInfo
{
private:
DriverName name_; // auto, unknown, amiplus, lse_07_17, multical21 etc
vector<DriverName> name_aliases_; // Secondary names that will map to this driver.
LinkModeSet linkmodes_; // C1, T1, S1 or combinations thereof.
Translate::Lookup mfct_tpl_status_bits_; // Translate any mfct specific bits in tpl status.
MeterType type_; // Water, Electricity etc.
function<shared_ptr<Meter>(MeterInfo&,DriverInfo&di)> constructor_; // Invoke this to create an instance of the driver.
vector<DriverDetect> detect_;
vector<string> default_fields_;
int force_mfct_index_ = -1; // Used for meters not declaring mfct specific data using the dif 0f.
bool has_process_content_ = false; // Mark this driver as having mfct specific decoding.
XMQDoc *dynamic_driver_ {}; // Configuration loaded from driver file.
string dynamic_file_name_; // Name of actual loaded driver file.
public:
~DriverInfo();
DriverInfo() {};
void setName(std::string n) { name_ = n; }
void addNameAlias(std::string n) { name_aliases_.push_back(n); }
void setMeterType(MeterType t) { type_ = t; }
void setDefaultFields(string f) { default_fields_ = splitString(f, ','); }
void addLinkMode(LinkMode lm) { linkmodes_.addLinkMode(lm); }
void forceMfctIndex(int i) { force_mfct_index_ = i; }
void setConstructor(function<shared_ptr<Meter>(MeterInfo&,DriverInfo&)> c) { constructor_ = c; }
void addDetection(uint16_t mfct, uchar type, uchar ver) { detect_.push_back({ mfct, type, ver }); }
void usesProcessContent() { has_process_content_ = true; }
void setDynamic(const string &file_name, XMQDoc *driver) { dynamic_file_name_ = file_name; dynamic_driver_ = driver; }
XMQDoc *getDynamicDriver() { return dynamic_driver_; }
const string &getDynamicFileName() { return dynamic_file_name_; }
vector<DriverDetect> &detect() { return detect_; }
DriverName name() { return name_; }
vector<DriverName>& nameAliases() { return name_aliases_; }
bool hasDriverName(DriverName dn) {
if (name_ == dn) return true;
for (auto &i : name_aliases_) if (i == dn) return true;
return false;
}
MeterType type() { return type_; }
vector<string>& defaultFields() { return default_fields_; }
LinkModeSet linkModes() { return linkmodes_; }
Translate::Lookup &mfctTPLStatusBits() { return mfct_tpl_status_bits_; }
shared_ptr<Meter> construct(MeterInfo& mi) { return constructor_(mi, *this); }
bool detect(uint16_t mfct, uchar type, uchar version);
bool isValidMedia(uchar type);
bool isCloseEnoughMedia(uchar type);
int forceMfctIndex() { return force_mfct_index_; }
bool hasProcessContent() { return has_process_content_; }
};
bool registerDriver(function<void(DriverInfo&di)> setup);
// Lookup (and load if necessary) driver from memory or disk.
DriverInfo *lookupDriver(string name);
bool lookupDriverInfo(const string& driver, DriverInfo *di = NULL);
// Return the best driver match for a telegram.
DriverInfo pickMeterDriver(Telegram *t);
// Return true for mbus and S2/C2/T2 drivers.
bool driverNeedsPolling(DriverName& dn);
string loadDriver(const string &file, const char *content);
vector<DriverInfo*>& allDrivers();
////////////////////////////////////////////////////////////////////////////////////////////////////////////
enum class VifScaling
{
Auto, // Scale to normalized VIF unit (ie kwh, m3, m3h etc)
None, // No auto scaling.
Unknown
};
const char* toString(VifScaling s);
VifScaling toVifScaling(const char *s);
enum class DifSignedness
{
Signed, // By default the binary values are interpreted as signed.
Unsigned, // We can override for non-compliant meters.
Unknown
};
const char* toString(DifSignedness s);
DifSignedness toDifSignedness(const char *s);
enum PrintProperty
{
REQUIRED = 1, // If no data has arrived, then print this field anyway with NaN or null.
DEPRECATED = 2, // This field is about to be removed or changed in a newer driver, which will have a new name.
STATUS = 4, // This is >the< status field and it should read OK of not error flags are set.
INCLUDE_TPL_STATUS = 8, // This text field also includes the tpl status decoding. multiple OK:s collapse to a single OK.
INJECT_INTO_STATUS = 16, // This text field is injected into the already defined status field. multiple OK:s collapse.
HIDE = 32, // This field is only used in calculations, do not print it!
Unknown = 1024
};
int toBit(PrintProperty p);
const char* toString(PrintProperty p);
PrintProperty toPrintProperty(const char *s);
struct PrintProperties
{
PrintProperties(int x) : props_(x) {}
bool hasREQUIRED() { return props_ & PrintProperty::REQUIRED; }
bool hasDEPRECATED() { return props_ & PrintProperty::DEPRECATED; }
bool hasSTATUS() { return props_ & PrintProperty::STATUS; }
bool hasINCLUDETPLSTATUS() { return props_ & PrintProperty::INCLUDE_TPL_STATUS; }
bool hasINJECTINTOSTATUS() { return props_ & PrintProperty::INJECT_INTO_STATUS; }
bool hasHIDE() { return props_ & PrintProperty::HIDE; }
bool hasUnknown() { return props_ & PrintProperty::Unknown; }
private:
int props_;
};
// Parse a string like DEPRECATED,HIDE into bits.
PrintProperties toPrintProperties(string s);
#define DEFAULT_PRINT_PROPERTIES 0
struct FieldInfo
{
~FieldInfo();
FieldInfo(int index,
string vname,
Quantity quantity,
Unit display_unit,
VifScaling vif_scaling,
DifSignedness dif_signedness,
double scale,
FieldMatcher matcher,
string help,
PrintProperties print_properties,
function<double(Unit)> get_numeric_value_override,
function<string()> get_string_value_override,
function<void(Unit,double)> set_numeric_value_override,
function<void(string)> set_string_value_override,
Translate::Lookup lookup,
Formula *formula
);
int index() { return index_; }
string vname() { return vname_; }
Quantity xuantity() { return xuantity_; }
Unit displayUnit() { return display_unit_; }
VifScaling vifScaling() { return vif_scaling_; }
DifSignedness difSignedness() { return dif_signedness_; }
double scale() { return scale_; }
FieldMatcher& matcher() { return matcher_; }
string help() { return help_; }
PrintProperties printProperties() { return print_properties_; }
bool extractNumeric(Meter *m, Telegram *t, DVEntry *dve = NULL);
bool extractString(Meter *m, Telegram *t, DVEntry *dve = NULL);
bool hasMatcher();
bool hasFormula();
bool matches(DVEntry *dve);
void performExtraction(Meter *m, Telegram *t, DVEntry *dve);
void performCalculation(Meter *m);
string renderJsonOnlyDefaultUnit(Meter *m);
string renderJson(Meter *m, DVEntry *dve);
string renderJsonText(Meter *m, DVEntry *dve);
// Render the field name based on the actual field from the telegram.
// A FieldInfo can be declared to handle any number of storage fields of a certain range.
// The vname is then a pattern total_at_month_{storage_counter} that gets translated into
// total_at_month_2 (for the dventry with storage nr 2.)
string generateFieldNameWithUnit(DVEntry *dve);
string generateFieldNameNoUnit(DVEntry *dve);
// Check if the meter object stores a value for this field.
bool hasValue(Meter *m);
Translate::Lookup& lookup() { return lookup_; }
string str();
private:
int index_; // The field infos for a meter are ordered.
string vname_; // Value name, like: total current previous target, ie no unit suffix.
Quantity xuantity_; // Quantity: Energy, Volume
Unit display_unit_; // Selected display unit for above quantity: KWH, M3
VifScaling vif_scaling_;
DifSignedness dif_signedness_;
double scale_; // A hardcoded scale factor. Used only for manufacturer specific values with unknown units for the vifs.
FieldMatcher matcher_;
string help_; // Helpful information on this meters use of this value.
PrintProperties print_properties_;
// Normally the values are stored inside the meter object using its setNumeric/setString/getNumeric/getString
// But for special fields we can override this default location with these setters/getters.
function<double(Unit)> get_numeric_value_override_; // Callback to fetch the value from the meter.
function<string()> get_string_value_override_; // Callback to fetch the value from the meter.
function<void(Unit,double)> set_numeric_value_override_; // Call back to set the value in the c++ object
function<void(string)> set_string_value_override_; // Call back to set the value string in the c++ object
// Lookup bits to strings.
Translate::Lookup lookup_;
// For calculated fields.
shared_ptr<Formula> formula_;
// For the generated field name.
shared_ptr<StringInterpolator> field_name_;
// If the field name template could not be parsed.
bool valid_field_name_ {};
};
struct BusManager;
struct Meter
{
// Meters are instantiated on the fly from a template, when a telegram arrives
// and no exact meter exists. Index 1 is the first meter created etc.
virtual int index() = 0;
virtual void setIndex(int i) = 0;
// Use this bus to send messages to the meter.
virtual string bus() = 0;
// This meter listens to these address expressions.
virtual std::vector<AddressExpression>& addressExpressions() = 0;
virtual IdentityMode identityMode() = 0;
// This meter can report these fields, like total_m3, temp_c.
virtual vector<FieldInfo> &fieldInfos() = 0;
virtual vector<string> &extraConstantFields() = 0;
// Either the default fields specified in the driver, or override fields in the meter configuration file.
virtual vector<string> &selectedFields() = 0;
virtual void setSelectedFields(vector<string> &f) = 0;
virtual string name() = 0;
virtual DriverName driverName() = 0;
virtual string datetimeOfUpdateHumanReadable() = 0;
virtual string datetimeOfUpdateRobot() = 0;
virtual string unixTimestampOfUpdate() = 0;
virtual time_t timestampLastUpdate() = 0;
virtual void setPollInterval(time_t interval) = 0;
virtual time_t pollInterval() = 0;
virtual bool usesPolling() = 0;
virtual void setNumericValue(string vname, Unit u, double v) = 0;
virtual void setNumericValue(FieldInfo *fi, DVEntry *dve, Unit u, double v) = 0;
virtual double getNumericValue(string vname, Unit u) = 0;
virtual double getNumericValue(FieldInfo *fi, Unit u) = 0;
virtual void setStringValue(FieldInfo *fi, std::string v, DVEntry *dve) = 0;
virtual void setStringValue(string vname, std::string v, DVEntry *dve = NULL) = 0;
virtual std::string getStringValue(FieldInfo *fi) = 0;
virtual std::string decodeTPLStatusByte(uchar sts) = 0;
virtual void onUpdate(std::function<void(Telegram*t,Meter*)> cb) = 0;
virtual int numUpdates() = 0;
virtual void createMeterEnv(string id,
vector<string> *envs,
vector<string> *more_json) = 0;
virtual void printMeter(Telegram *t,
string *human_readable,
string *fields, char separator,
string *json,
vector<string> *envs,
vector<string> *more_json,
vector<string> *selected_fields,
bool pretty_print_json) = 0;
// The handleTelegram expects an input_frame where the DLL crcs have been removed.
// Returns true of this meter handled this telegram!
// Sets id_match to true, if there was an id match, even though the telegram could not be properly handled.
virtual bool handleTelegram(AboutTelegram &about, vector<uchar> input_frame,
bool simulated, std::vector<Address> *addresses,
bool *id_match, Telegram *out_t = NULL) = 0;
virtual MeterKeys *meterKeys() = 0;
virtual void addExtraCalculatedField(std::string ecf) = 0;
virtual void addShellMeterAdded(std::string cmdline) = 0;
virtual void addShellMeterUpdated(std::string cmdline) = 0;
virtual vector<string> &shellCmdlinesMeterAdded() = 0;
virtual vector<string> &shellCmdlinesMeterUpdated() = 0;
virtual void poll(shared_ptr<BusManager> bus) = 0;
virtual FieldInfo *findFieldInfo(string vname, Quantity xuantity) = 0;
virtual string renderJsonOnlyDefaultUnit(string vname, Quantity xuantity) = 0;
virtual string debugValues() = 0;
virtual ~Meter() = default;
};
struct MeterManager
{
virtual void addMeterTemplate(MeterInfo &mi) = 0;
virtual void addMeter(shared_ptr<Meter> meter) = 0;
virtual void triggerMeterAdded(shared_ptr<Meter> meter) = 0;
virtual Meter*lastAddedMeter() = 0;
virtual void removeAllMeters() = 0;
virtual void forEachMeter(std::function<void(Meter*)> cb) = 0;
virtual bool handleTelegram(AboutTelegram &about, vector<uchar> data, bool simulated) = 0;
virtual bool hasAllMetersReceivedATelegram() = 0;
virtual bool hasMeters() = 0;
virtual void onTelegram(function<bool(AboutTelegram&,vector<uchar>)> cb) = 0;
virtual void whenMeterAdded(std::function<void(shared_ptr<Meter>)> cb) = 0;
virtual void whenMeterUpdated(std::function<void(Telegram*t,Meter*)> cb) = 0;
virtual void pollMeters(shared_ptr<BusManager> bus) = 0;
virtual void analyzeEnabled(bool b, OutputFormat f, string force_driver, string key, bool verbose, int profile) = 0;
virtual void analyzeTelegram(AboutTelegram &about, vector<uchar> &input_frame, bool simulated) = 0;
virtual ~MeterManager() = default;
};
shared_ptr<MeterManager> createMeterManager(bool daemon);
const char *toString(MeterType type);
MeterType toMeterType(std::string type);
string toString(DriverInfo &driver);
LinkModeSet toMeterLinkModeSet(const string& driver);
struct Configuration;
struct MeterInfo;
shared_ptr<Meter> createMeter(MeterInfo *mi);
const char *availableMeterTypes();
#endif