wmbusmeters/src/driver_vario451mid.cc

105 wiersze
4.0 KiB
C++

/*
Copyright (C) 2022 Fredrik Öhrström (gpl-3.0-or-later)
This program is free software: you can redistribute it and/or modify
it under the terms of the GNU General Public License as published by
the Free Software Foundation, either version 3 of the License, or
(at your option) any later version.
This program is distributed in the hope that it will be useful,
but WITHOUT ANY WARRANTY; without even the implied warranty of
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
GNU General Public License for more details.
You should have received a copy of the GNU General Public License
along with this program. If not, see <http://www.gnu.org/licenses/>.
*/
#include"meters_common_implementation.h"
namespace
{
struct Driver : public virtual MeterCommonImplementation
{
Driver(MeterInfo &mi, DriverInfo &di);
};
static bool ok = registerDriver([](DriverInfo&di)
{
di.setName("vario451mid");
di.setDefaultFields("name,id,total_energy_consumption_kwh,energy_at_old_date_kwh,energy_at_set_date_kwh,timestamp");
di.setMeterType(MeterType::HeatMeter);
// Mode 7
di.addLinkMode(LinkMode::T1);
di.addDetection(MANUFACTURER_TCH, 0x04, 0x17);
di.setConstructor([](MeterInfo& mi, DriverInfo& di){ return shared_ptr<Meter>(new Driver(mi, di)); });
});
Driver::Driver(MeterInfo &mi, DriverInfo &di) : MeterCommonImplementation(mi, di)
{
addNumericFieldWithExtractor(
"total_energy_consumption",
"The total energy consumption recorded by this meter.",
DEFAULT_PRINT_PROPERTIES,
Quantity::Energy,
VifScaling::Auto, DifSignedness::Signed,
FieldMatcher::build()
.set(MeasurementType::Instantaneous)
.set(VIFRange::AnyEnergyVIF)
);
addNumericFieldWithExtractor(
"energy_at_old_date",
"The total energy consumption recorded when?",
DEFAULT_PRINT_PROPERTIES,
Quantity::Energy,
VifScaling::Auto, DifSignedness::Signed,
FieldMatcher::build()
.set(MeasurementType::Instantaneous)
.set(VIFRange::AnyEnergyVIF)
.set(StorageNr(1))
);
addNumericFieldWithExtractor(
"old",
"The last billing old date?",
DEFAULT_PRINT_PROPERTIES,
Quantity::PointInTime,
VifScaling::Auto, DifSignedness::Signed,
FieldMatcher::build()
.set(MeasurementType::Instantaneous)
.set(VIFRange::Date)
.set(StorageNr(1)),
Unit::DateLT);
addNumericFieldWithExtractor(
"energy_at_set_date",
"The total energy consumption recorded by this meter at the due date.",
DEFAULT_PRINT_PROPERTIES,
Quantity::Energy,
VifScaling::Auto, DifSignedness::Signed,
FieldMatcher::build()
.set(MeasurementType::Instantaneous)
.set(VIFRange::AnyEnergyVIF)
.set(StorageNr(8))
);
addNumericFieldWithExtractor(
"set",
"The last billing set date.",
DEFAULT_PRINT_PROPERTIES,
Quantity::PointInTime,
VifScaling::Auto, DifSignedness::Signed,
FieldMatcher::build()
.set(MeasurementType::Instantaneous)
.set(VIFRange::Date)
.set(StorageNr(8)),
Unit::DateLT);
}
}
// Test: Heato vario451mid 94430412 NOKEY
// telegram=734468501204439417048c0084900f002c2536700000B767B64527c50ac67a33005007102f2f8404062846000082046c9f2c8d04861f1e72fe00000000000000000000000000000000000000000000000000000000440600000000426cffff0406c94700002f2f2f2f2f2f2f2f2f2f2f2f2f2f2f
// {"media":"heat","meter":"vario451mid","name":"Heato","id":"94430412","total_energy_consumption_kwh":18377,"energy_at_old_date_kwh":0,"old_date":"2128-03-31","energy_at_set_date_kwh":17960,"set_date":"2020-12-31","timestamp":"1111-11-11T11:11:11Z"}
// |Heato;94430412;18377;0;17960;1111-11-11 11:11.11