/* Copyright (C) 2022 Fredrik Öhrström (gpl-3.0-or-later) This program is free software: you can redistribute it and/or modify it under the terms of the GNU General Public License as published by the Free Software Foundation, either version 3 of the License, or (at your option) any later version. This program is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License for more details. You should have received a copy of the GNU General Public License along with this program. If not, see . */ #include"meters_common_implementation.h" namespace { struct Driver : public virtual MeterCommonImplementation { Driver(MeterInfo &mi, DriverInfo &di); }; static bool ok = registerDriver([](DriverInfo&di) { di.setName("qualcosonic"); di.setMeterType(MeterType::HeatCoolingMeter); di.addLinkMode(LinkMode::C1); di.addDetection(MANUFACTURER_AXI, 0x0d, 0x0b); di.setConstructor([](MeterInfo& mi, DriverInfo& di){ return shared_ptr(new Driver(mi, di)); }); }); Driver::Driver(MeterInfo &mi, DriverInfo &di) : MeterCommonImplementation(mi, di) { addOptionalCommonFields("fabrication_no,operating_time_h,on_time_h,meter_datetime,meter_datetime_at_error"); addOptionalFlowRelatedFields("total_m3,flow_temperature_c,return_temperature_c,flow_return_temperature_difference_c,volume_flow_m3h"); addStringFieldWithExtractorAndLookup( "status", "Meter status. Includes both meter error field and tpl status field.", PrintProperty::JSON | PrintProperty::FIELD | PrintProperty::IMPORTANT | PrintProperty::STATUS | PrintProperty::JOIN_TPL_STATUS, FieldMatcher::build() .set(VIFRange::ErrorFlags), Translate::Lookup( { { { "ERROR_FLAGS", Translate::Type::BitToString, AlwaysTrigger, MaskBits(0xffffffff), "OK", { /* What do these bits mean? There are a lot of them... */ } }, }, })); addNumericFieldWithExtractor( "total_heat_energy", "The total heating energy consumption recorded by this meter.", PrintProperty::FIELD | PrintProperty::JSON | PrintProperty::IMPORTANT, Quantity::Energy, VifScaling::Auto, FieldMatcher::build() .set(MeasurementType::Instantaneous) .set(VIFRange::AnyEnergyVIF) .add(VIFCombinable::ForwardFlow) ); addNumericFieldWithExtractor( "total_cooling_energy", "The total cooling energy consumption recorded by this meter.", PrintProperty::FIELD | PrintProperty::JSON | PrintProperty::IMPORTANT, Quantity::Energy, VifScaling::Auto, FieldMatcher::build() .set(MeasurementType::Instantaneous) .set(VIFRange::AnyEnergyVIF) .add(VIFCombinable::BackwardFlow) ); addNumericFieldWithExtractor( "power", "The current power consumption.", PrintProperty::JSON | PrintProperty::FIELD, Quantity::Power, VifScaling::AutoSigned, FieldMatcher::build() .set(MeasurementType::Instantaneous) .set(VIFRange::AnyPowerVIF) ); addStringFieldWithExtractor( "target_datetime", "Date and time when the previous billing period ended.", PrintProperty::FIELD | PrintProperty::JSON, FieldMatcher::build() .set(MeasurementType::Instantaneous) .set(VIFRange::DateTime) .set(StorageNr(16)) ); addNumericFieldWithExtractor( "target_heat_energy", "The heating energy consumption recorded at the end of the previous billing period.", PrintProperty::FIELD | PrintProperty::JSON, Quantity::Energy, VifScaling::Auto, FieldMatcher::build() .set(MeasurementType::Instantaneous) .set(VIFRange::AnyEnergyVIF) .add(VIFCombinable::ForwardFlow) .set(StorageNr(16)) ); addNumericFieldWithExtractor( "target_cooling_energy", "The cooling energy consumption recorded at the end of the previous billing period.", PrintProperty::FIELD | PrintProperty::JSON, Quantity::Energy, VifScaling::Auto, FieldMatcher::build() .set(MeasurementType::Instantaneous) .set(VIFRange::AnyEnergyVIF) .add(VIFCombinable::BackwardFlow) .set(StorageNr(16)) ); } } // Test: qualco qualcosonic 03016408 NOKEY // telegram=|76440907086401030B0d7a78000000046d030fB726346d0000010134fd170000000004200f13cf0104240f13cf0104863B0000000004863cdc0000000413B5150600042B86f1ffff043B030200000259c002025d2c05026194fd0c780864010384086d3B17Bf258408863B000000008408863c0B000000| // {"media":"heat/cooling load","meter":"qualcosonic","name":"qualco","id":"03016408","fabrication_no":"03016408","operating_time_h":8430.013056,"on_time_h":8430.013056,"meter_datetime":"2021-06-23 15:03","meter_datetime_at_error":"2000-01-01 00:00","total_m3":398.773,"flow_temperature_c":7.04,"return_temperature_c":13.24,"flow_return_temperature_difference_c":-6.2,"volume_flow_m3h":0.515,"status":"OK","total_heat_energy_kwh":0,"total_cooling_energy_kwh":220,"power_kw":-3.706,"target_datetime":"2021-05-31 23:59","target_heat_energy_kwh":0,"target_cooling_energy_kwh":11,"timestamp":"1111-11-11T11:11:11Z"} // |qualco;03016408;OK;0.000000;220.000000;-3.706000;2021-05-31 23:59;0.000000;11.000000;1111-11-11 11:11.11