Wykres commitów

473 Commity (daab1b303eac7bcf50e3d0e5a65ace17882d5386)

Autor SHA1 Wiadomość Data
Fredrik Öhrström daab1b303e
Merge pull request #237 from CuBiC3D/fix-tch-dataiii
Fix parsing for Techem HCA with version 0x94
2021-02-07 11:19:03 +01:00
Fredrik Öhrström 3ed662c07c Added tpl ci A3h which probably means manufacturer specific. 2021-02-07 08:02:56 +01:00
Fredrik Öhrström be9bc54da5 Remove unnecessary comments. 2021-02-07 07:53:19 +01:00
Waldemar Faist a78aaec991 fix: correct offsets for techem hca 2021-02-06 18:29:47 +01:00
Fredrik Öhrström cc49118cc9
Merge pull request #232 from CuBiC3D/feat-cul-rssi
Support RSSI on CUL
2021-02-06 07:15:24 +01:00
Waldemar Faist 5dde4868c7 feat: support RSSI on CUL 2021-02-05 15:31:01 +01:00
Vincent Privat 0fe2f5403a
Fix IZAR previous_alarms description 2021-02-04 21:58:11 +01:00
Fredrik Öhrström fa87570ea0 Change -NAN to NAN since macosx always renders -NAN as NAN.... 2021-02-03 12:09:41 +01:00
Fredrik Öhrström 9720d0283f Change from stdc++ include to algorithm include. 2021-02-03 10:13:30 +01:00
Fredrik Öhrström bd397261a5 Update manufacturer flag ids. 2021-02-03 07:17:21 +01:00
Fredrik Öhrström 87fe95ef25 Fix mac check when parsing afl is done twice. 2021-01-30 22:19:13 +01:00
Fredrik Öhrström 84960f2245 Restore current_status json key for waterstarm and fix debugging error for info codes. 2021-01-30 18:06:47 +01:00
Fredrik Öhrström d50f13b240 Now properly handles different dll id and tpl id. 2021-01-30 17:58:00 +01:00
Fredrik Öhrström 7226a6a1a2 Adjust field name current_status to just status for the waterstar meter. 2021-01-30 09:26:35 +01:00
Fredrik Öhrström be4b799105 Adjust names for volt and ampere units to be _v and _a in json fields. 2021-01-30 09:07:14 +01:00
Fredrik Öhrström 2a6ba20cbe Include regressions tests for gransystem. 2021-01-30 08:52:25 +01:00
Xael South 2b308ebe1c ccx01 2021-01-29 16:20:54 +00:00
Xael South 4f27d700fd ccx01 2021-01-29 16:20:03 +00:00
Xael South 935667a7b9 add gss cc101 and cc301 2021-01-29 16:00:10 +00:00
Fredrik Öhrström 73c18c1831 Added evo868 water wmbus module. 2021-01-26 22:22:59 +01:00
Fredrik Öhrström f29e819afd Add missin file. 2021-01-26 19:03:12 +01:00
Fredrik Öhrström 0cf7f864dd Properly create IV for AES CBC IV for telegrams having both dll_id and tpl_id. 2021-01-26 18:39:35 +01:00
Fredrik Öhrström 8d8b1a2a9b Added whe5x hca. 2021-01-26 17:17:29 +01:00
Fredrik Öhrström 5b5e9b9dee Print all warnings for first telegram triggering alarms. Only start ignoring alarms for next telegram. 2021-01-24 21:44:20 +01:00
Fredrik Öhrström f780f74384 Allow T1 mode for multical302 2021-01-24 20:36:59 +01:00
Fredrik Öhrström b243686ad6 Fix multical 803 to expect Joule and not KWh in telegram. 2021-01-24 20:06:21 +01:00
Fredrik Öhrström b625b691dd Fix test. 2021-01-24 16:15:34 +01:00
Alex Muthmann 0893c82106
Remove scaling for Techem Compact 5
As discussed in #217 we don#t need to scale down the values for the heat meter.
2021-01-24 13:37:03 +01:00
Fredrik Öhrström 650d1c76ab Ignore telegrams matching a wildcard but wrong driver. Keep telegrams with exact id match and wrong driver. 2021-01-24 13:35:44 +01:00
Fredrik Öhrström 28b416dfd6
Merge branch 'master' into feature/Techem_CompactVe 2021-01-24 11:25:51 +01:00
Fredrik Öhrström 5b29b9de4a Added regression test for compact5 heat meter. 2021-01-24 11:18:54 +01:00
Fredrik Öhrström f1c5d6ef9d Fix json field name. 2021-01-24 09:08:36 +01:00
Alex Muthmann 82c6bd3a55 Add support for Compact Ve Heat Meter 2021-01-22 23:36:03 +01:00
Marc-André Kolly 4c9e209746
Standardize status field naming (`status` instead of `current_status`) and implement known error_codes 2021-01-11 15:33:30 +01:00
Marc-André Kolly 3b65f39429
Lorenz Water meter/Engelmann WaterStarM also exists as 0x07 (Water meter) 2021-01-11 15:19:25 +01:00
Fredrik Öhrström cff3eb5b30 Added yet another media type for the izar driver lookup. 2021-01-06 23:15:37 +01:00
Fredrik Öhrström 8f7a681da2 Added fhkvdataiv. 2021-01-06 19:48:56 +01:00
Fredrik Öhrström 0d93f0dcbc Only pring warning unknown or wrong driver once. 2021-01-06 13:46:12 +01:00
Fredrik Öhrström 6638e4f88f Only print warning about failed decryption once. 2021-01-06 12:46:37 +01:00
Fredrik Öhrström 18cbf887b2 Added minimal stub for tsd2. 2020-12-31 14:46:05 +01:00
Fredrik Öhrström eb33a0bf13 Prevent wmbusmeters from being confused by a file named rtlwmbus. 2020-12-31 10:42:53 +01:00
Fredrik Öhrström 781b084260 Add error message detecting missing pidfile argument to daemon. 2020-12-31 10:18:43 +01:00
Fredrik Öhrström cde87b9698 Added stub for whe46x driver, meter not yet understood. 2020-12-28 19:20:31 +01:00
Fredrik Öhrström 2616f64cb7 Fix for omnipower provided by janusboandersen. 2020-12-28 17:47:21 +01:00
dddevvv 871a9a5872 add M3/H to/from L/H conversion 2020-12-17 22:10:14 +00:00
dddevvv 73d4f9d680 multical403: recognize 0xF VIF byte (energy MJ) 2020-12-17 22:07:52 +00:00
Fredrik Öhrström ba0a916207
Merge pull request #195 from balczezzz/balczezzz-patch-2
Add files via upload
2020-12-10 18:09:07 +01:00
Fredrik Öhrström 8070d6e638
Merge pull request #196 from balczezzz/balczezzz-patch-1
Update dvparser.h
2020-12-10 18:08:54 +01:00
balczezzz 43b44e9217
Update meters.h
Support for BMETERS HYDROCALM3
2020-12-09 22:16:44 +01:00
balczezzz 4667f56840
Add files via upload
Added meter file for BMETERS HYDROCALM3
2020-12-09 22:10:12 +01:00