Added water meter Diehl IZAR RC I G4.

pull/278/head
Fredrik Öhrström 2021-04-10 17:58:32 +02:00
rodzic da690f2afd
commit f753449750
9 zmienionych plików z 114 dodań i 1 usunięć

Wyświetl plik

@ -1,3 +1,6 @@
Support added for the water meter Diehl IZAR RC I G4.
Version 1.3.0: 2021-04-09 Version 1.3.0: 2021-04-09
You can now use "auto" as a meter driver. You can now use "auto" as a meter driver.

Wyświetl plik

@ -146,6 +146,7 @@ METER_OBJS:=\
$(BUILD)/meter_apator162.o \ $(BUILD)/meter_apator162.o \
$(BUILD)/meter_cma12w.o \ $(BUILD)/meter_cma12w.o \
$(BUILD)/meter_compact5.o \ $(BUILD)/meter_compact5.o \
$(BUILD)/meter_dme_07.o \
$(BUILD)/meter_ebzwmbe.o \ $(BUILD)/meter_ebzwmbe.o \
$(BUILD)/meter_ehzp.o \ $(BUILD)/meter_ehzp.o \
$(BUILD)/meter_esyswm.o \ $(BUILD)/meter_esyswm.o \

Wyświetl plik

@ -286,6 +286,7 @@ Aquametro/Integra Topas Es Kr (topaseskr)
Bmeters Hydrodigit (hydrodigit) (partly non-standard protocol) Bmeters Hydrodigit (hydrodigit) (partly non-standard protocol)
Diehl/Sappel IZAR RC 868 I R4 PL (izar) (non-standard protocol) Diehl/Sappel IZAR RC 868 I R4 PL (izar) (non-standard protocol)
Diehl HYDRUS (hydrus) Diehl HYDRUS (hydrus)
Diehl IZAR RC I G4 (dme_07)
Elster Merlin 868 (emerlin868) Elster Merlin 868 (emerlin868)
Elster V200H (ev200) Elster V200H (ev200)
Maddalena EVO 868 (evo868) Maddalena EVO 868 (evo868)

Wyświetl plik

@ -235,3 +235,8 @@ telegram=|534424232004256092687A370045752235854DEEEA5939FAD81C25FEEF5A23C38FB916
telegram=|51440186010905001837721956880101064004DA000020026CA9220E017799241103000C13641320000A2D00000A5A90060A5E800544050E77000001FD0C010A6564370AFD4731030A274907047F00000002| telegram=|51440186010905001837721956880101064004DA000020026CA9220E017799241103000C13641320000A2D00000A5A90060A5E800544050E77000001FD0C010A6564370AFD4731030A274907047F00000002|
{"media":"heat","meter":"elf","name":"Hetta","id":"01885619","meter_date":"2021-02-09","total_energy_consumption_kwh":3112.49977,"current_power_consumption_kw":0,"total_volume_m3":201.364,"total_energy_consumption_at_date_kwh":3047.8,"flow_temperature_c":69,"return_temperature_c":58,"external_temperature_c":37.64,"status":"200000","operating_time_h":44760,"version":"1","battery_v":0,"timestamp":"1111-11-11T11:11:11Z"} {"media":"heat","meter":"elf","name":"Hetta","id":"01885619","meter_date":"2021-02-09","total_energy_consumption_kwh":3112.49977,"current_power_consumption_kw":0,"total_volume_m3":201.364,"total_energy_consumption_at_date_kwh":3047.8,"flow_temperature_c":69,"return_temperature_c":58,"external_temperature_c":37.64,"status":"200000","operating_time_h":44760,"version":"1","battery_v":0,"timestamp":"1111-11-11T11:11:11Z"}
|Hetta;01885619;3112.499770;0.000000;201.364000;69.000000;58.000000;37.640000;200000;1111-11-11 11:11.11 |Hetta;01885619;3112.499770;0.000000;201.364000;69.000000;58.000000;37.640000;200000;1111-11-11 11:11.11
# Test Diehl IZAR RC I G4 water meter
telegram=|1E44A511909192937B077A9F0010052F2F|04130347030002FD1700002F2F2F|
{"media":"water","meter":"dme_07","name":"DigiWasser","id":"93929190","total_m3":214.787,"status":"OK","timestamp":"1111-11-11T11:11:11Z"}
|DigiWasser;93929190;214.787000;OK;1111-11-11 11:11.11

Wyświetl plik

@ -33,6 +33,7 @@
X(COMPACT5, MANUFACTURER_TCH, 0xc3, 0x45) \ X(COMPACT5, MANUFACTURER_TCH, 0xc3, 0x45) \
X(COMPACT5, MANUFACTURER_TCH, 0x43, 0x22) \ X(COMPACT5, MANUFACTURER_TCH, 0x43, 0x22) \
X(COMPACT5, MANUFACTURER_TCH, 0x43, 0x45) \ X(COMPACT5, MANUFACTURER_TCH, 0x43, 0x45) \
X(DME_07, MANUFACTURER_DME, 0x07, 0x7b) \
X(EBZWMBE, MANUFACTURER_EBZ, 0x37, 0x02) \ X(EBZWMBE, MANUFACTURER_EBZ, 0x37, 0x02) \
X(EURISII, MANUFACTURER_INE, 0x08, 0x55) \ X(EURISII, MANUFACTURER_INE, 0x08, 0x55) \
X(EHZP, MANUFACTURER_EMH, 0x02, 0x02) \ X(EHZP, MANUFACTURER_EMH, 0x02, 0x02) \

Wyświetl plik

@ -0,0 +1,95 @@
/*
Copyright (C) 2021 Fredrik Öhrström
This program is free software: you can redistribute it and/or modify
it under the terms of the GNU General Public License as published by
the Free Software Foundation, either version 3 of the License, or
(at your option) any later version.
This program is distributed in the hope that it will be useful,
but WITHOUT ANY WARRANTY; without even the implied warranty of
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
GNU General Public License for more details.
You should have received a copy of the GNU General Public License
along with this program. If not, see <http://www.gnu.org/licenses/>.
*/
#include"dvparser.h"
#include"meters.h"
#include"meters_common_implementation.h"
#include"wmbus.h"
#include"wmbus_utils.h"
#include"util.h"
using namespace std;
struct MeterDME_07 : public virtual WaterMeter, public virtual MeterCommonImplementation {
MeterDME_07(MeterInfo &mi);
// Total water counted through the meter
double totalWaterConsumption(Unit u);
bool hasTotalWaterConsumption();
private:
void processContent(Telegram *t);
string status();
double total_water_consumption_m3_ {};
uint16_t error_codes_ {};
};
shared_ptr<WaterMeter> createDME_07(MeterInfo &mi)
{
return shared_ptr<WaterMeter>(new MeterDME_07(mi));
}
MeterDME_07::MeterDME_07(MeterInfo &mi) :
MeterCommonImplementation(mi, MeterDriver::DME_07)
{
setExpectedTPLSecurityMode(TPLSecurityMode::AES_CBC_IV);
addLinkMode(LinkMode::T1);
addPrint("total", Quantity::Volume,
[&](Unit u){ return totalWaterConsumption(u); },
"The total water consumption recorded by this meter.",
true, true);
addPrint("status", Quantity::Text,
[&](){ return status(); },
"Status of meter.",
true, true);
}
void MeterDME_07::processContent(Telegram *t)
{
int offset;
string key;
if(findKey(MeasurementType::Instantaneous, ValueInformation::Volume, 0, 0, &key, &t->values)) {
extractDVdouble(&t->values, key, &offset, &total_water_consumption_m3_);
t->addMoreExplanation(offset, " total consumption (%f m3)", total_water_consumption_m3_);
}
extractDVuint16(&t->values, "02FD17", &offset, &error_codes_);
t->addMoreExplanation(offset, " error codes (%s)", status().c_str());
}
double MeterDME_07::totalWaterConsumption(Unit u)
{
assertQuantity(u, Quantity::Volume);
return convert(total_water_consumption_m3_, Unit::M3, u);
}
bool MeterDME_07::hasTotalWaterConsumption()
{
return true;
}
string MeterDME_07::status()
{
if (error_codes_ == 0) return "OK";
// Can we decode the error bits more?
return tostrprintf("ERR %04x", error_codes_);
}

Wyświetl plik

@ -35,6 +35,7 @@
X(apator162, C1_bit|T1_bit, WaterMeter, APATOR162, Apator162) \ X(apator162, C1_bit|T1_bit, WaterMeter, APATOR162, Apator162) \
X(cma12w, C1_bit|T1_bit, TempHygroMeter, CMA12W, CMa12w) \ X(cma12w, C1_bit|T1_bit, TempHygroMeter, CMA12W, CMa12w) \
X(compact5, T1_bit, HeatMeter, COMPACT5, Compact5) \ X(compact5, T1_bit, HeatMeter, COMPACT5, Compact5) \
X(dme_07, T1_bit, WaterMeter, DME_07, DME_07) \
X(ebzwmbe, T1_bit, ElectricityMeter, EBZWMBE, EBZWMBE) \ X(ebzwmbe, T1_bit, ElectricityMeter, EBZWMBE, EBZWMBE) \
X(eurisii, T1_bit, HeatCostAllocationMeter, EURISII, EurisII) \ X(eurisii, T1_bit, HeatCostAllocationMeter, EURISII, EurisII) \
X(ehzp, T1_bit, ElectricityMeter, EHZP, EHZP) \ X(ehzp, T1_bit, ElectricityMeter, EHZP, EHZP) \

Wyświetl plik

@ -264,6 +264,11 @@ Received telegram from: 00050901
type: Heat meter (0x04) type: Heat meter (0x04)
ver: 0x40 ver: 0x40
driver: elf driver: elf
Received telegram from: 93929190
manufacturer: (DME) DIEHL Metering, Germany (0x11a5)
type: Water meter (0x07)
ver: 0x7b
driver: dme_07
EOF EOF
RES=$($PROG --logfile=$LOGFILE --t1 simulations/simulation_t1.txt 2>&1) RES=$($PROG --logfile=$LOGFILE --t1 simulations/simulation_t1.txt 2>&1)

Wyświetl plik

@ -51,7 +51,8 @@ METERS="MyWarmWater supercom587 12345678 NOKEY
Smokey tsd2 91633569 NOKEY Smokey tsd2 91633569 NOKEY
Sharky775 sharky 68926025 NOKEY Sharky775 sharky 68926025 NOKEY
Heating compact5 62626262 NOKEY Heating compact5 62626262 NOKEY
Hetta elf 01885619 NOKEY" Hetta elf 01885619 NOKEY
DigiWasser dme_07 93929190 NOKEY"