kopia lustrzana https://github.com/weetmuts/wmbusmeters
Merge pull request #937 from DeDragonSlayer/master
amiplus - add maximum power consumption field. This is calculated as …pull/949/head
commit
d135ed98bd
|
@ -35,7 +35,7 @@ telegram=|4E4401061010101002027A00004005_2F2F0E035040691500000B2B300300066D00790
|
|||
# Test amiplus/apator electricity meter with three phase voltages
|
||||
|
||||
telegram=|5E44B6105843250000027A2A005005_2F2F0C7835221400066D404708AC2A400E032022650900000E833C0000000000001B2B9647000B2B5510000BAB3C0000000AFDC9FC0135020AFDC9FC0245020AFDC9FC0339020BABC8FC100000002F2F|
|
||||
{"media":"electricity","meter":"amiplus","name":"MyElectricity2","id":"00254358","total_energy_consumption_kwh":9652.22,"current_power_consumption_kw":1.055,"total_energy_production_kwh":0,"current_power_production_kw":0,"voltage_at_phase_1_v":235,"voltage_at_phase_2_v":245,"voltage_at_phase_3_v":239,"device_date_time":"2021-10-12 08:07:00","timestamp":"1111-11-11T11:11:11Z"}
|
||||
{"media":"electricity","meter":"amiplus","name":"MyElectricity2","id":"00254358","total_energy_consumption_kwh":9652.22,"current_power_consumption_kw":1.055,"total_energy_production_kwh":0,"current_power_production_kw":0,"voltage_at_phase_1_v":235,"voltage_at_phase_2_v":245,"voltage_at_phase_3_v":239,"max_power_consumption_kw":4.796,"device_date_time":"2021-10-12 08:07:00","timestamp":"1111-11-11T11:11:11Z"}
|
||||
|MyElectricity2;00254358;9652.22;1.055;0;0;235;245;239;null;null;null;null;null;null;1111-11-11 11:11.11
|
||||
|
||||
|
||||
|
|
|
@ -184,6 +184,18 @@ namespace
|
|||
FieldMatcher::build()
|
||||
.set(DifVifKey("8E30833C"))
|
||||
);
|
||||
|
||||
addNumericFieldWithExtractor(
|
||||
"max_power_consumption",
|
||||
"The maximum demand indicator (maximum 15-min average power consumption recorded this month).",
|
||||
DEFAULT_PRINT_PROPERTIES,
|
||||
Quantity::Power,
|
||||
VifScaling::Auto,
|
||||
FieldMatcher::build()
|
||||
.set(MeasurementType::Maximum)
|
||||
.set(VIFRange::AnyPowerVIF)
|
||||
);
|
||||
|
||||
}
|
||||
}
|
||||
|
||||
|
@ -195,11 +207,11 @@ namespace
|
|||
// Test: MyElectricity2 amiplus 00254358 NOKEY
|
||||
// Comment: amiplus/apator electricity meter with three phase voltages
|
||||
// telegram=|5E44B6105843250000027A2A005005_2F2F0C7835221400066D404708AC2A400E032022650900000E833C0000000000001B2B9647000B2B5510000BAB3C0000000AFDC9FC0135020AFDC9FC0245020AFDC9FC0339020BABC8FC100000002F2F|
|
||||
// {"media":"electricity","meter":"amiplus","name":"MyElectricity2","id":"00254358","total_energy_consumption_kwh":9652.22,"current_power_consumption_kw":1.055,"total_energy_production_kwh":0,"current_power_production_kw":0,"voltage_at_phase_1_v":235,"voltage_at_phase_2_v":245,"voltage_at_phase_3_v":239,"device_date_time":"2021-10-12 08:07:00","timestamp":"1111-11-11T11:11:11Z"}
|
||||
// {"media":"electricity","meter":"amiplus","name":"MyElectricity2","id":"00254358","total_energy_consumption_kwh":9652.22,"current_power_consumption_kw":1.055,"total_energy_production_kwh":0,"current_power_production_kw":0,"voltage_at_phase_1_v":235,"voltage_at_phase_2_v":245,"voltage_at_phase_3_v":239,"max_power_consumption_kw":4.796,"device_date_time":"2021-10-12 08:07:00","timestamp":"1111-11-11T11:11:11Z"}
|
||||
// |MyElectricity2;00254358;9652.22;1.055;0;0;235;245;239;null;null;null;null;null;null;1111-11-11 11:11.11
|
||||
|
||||
// Test: MyElectricity3 amiplus 86064864 NOKEY
|
||||
// Comment: amiplus/apator electricity meter with three phase voltages and 2 tariffs.
|
||||
// telegram=|804401066448068602027A000070052F2F_066D1E5C11DA21400C78644806868E10036110012500008E20038106531800008E10833C9949000000008E20833C8606000000001B2B5228020B2B3217000BAB3C0000000AFDC9FC0131020AFDC9FC0225020AFDC9FC0331020BABC8FC100000002F2F2F2F2F2F2F2F2F2F2F2F2FDE47|
|
||||
// {"media":"electricity","meter":"amiplus","name":"MyElectricity3","id":"86064864","current_power_consumption_kw":1.732,"current_power_production_kw":0,"voltage_at_phase_1_v":231,"voltage_at_phase_2_v":225,"voltage_at_phase_3_v":231,"device_date_time":"2022-01-26 17:28:30","total_energy_consumption_tariff_1_kwh":25011.061,"total_energy_consumption_tariff_2_kwh":18530.681,"total_energy_production_tariff_1_kwh":4.999,"total_energy_production_tariff_2_kwh":0.686,"timestamp":"1111-11-11T11:11:11Z"}
|
||||
// {"media":"electricity","meter":"amiplus","name":"MyElectricity3","id":"86064864","current_power_consumption_kw":1.732,"current_power_production_kw":0,"voltage_at_phase_1_v":231,"voltage_at_phase_2_v":225,"voltage_at_phase_3_v":231,"device_date_time":"2022-01-26 17:28:30","total_energy_consumption_tariff_1_kwh":25011.061,"total_energy_consumption_tariff_2_kwh":18530.681,"total_energy_production_tariff_1_kwh":4.999,"total_energy_production_tariff_2_kwh":0.686,"max_power_consumption_kw":22.852,"timestamp":"1111-11-11T11:11:11Z"}
|
||||
// |MyElectricity3;86064864;null;1.732;null;0;231;225;231;25011.061;18530.681;null;4.999;0.686;null;1111-11-11 11:11.11
|
||||
|
|
|
@ -36,6 +36,7 @@ METER_TOTAL_ENERGY_CONSUMPTION_TARIFF_3_KWH
|
|||
METER_TOTAL_ENERGY_PRODUCTION_TARIFF_1_KWH
|
||||
METER_TOTAL_ENERGY_PRODUCTION_TARIFF_2_KWH
|
||||
METER_TOTAL_ENERGY_PRODUCTION_TARIFF_3_KWH
|
||||
METER_MAX_POWER_CONSUMPTION_KW
|
||||
EOF
|
||||
|
||||
if [ "$?" = "0" ]
|
||||
|
@ -86,6 +87,7 @@ total_energy_consumption_tariff_3_kwh The total energy consumption recorded by
|
|||
total_energy_production_tariff_1_kwh The total energy production recorded by this meter on tariff 1.
|
||||
total_energy_production_tariff_2_kwh The total energy production recorded by this meter on tariff 2.
|
||||
total_energy_production_tariff_3_kwh The total energy production recorded by this meter on tariff 3.
|
||||
max_power_consumption_kw The maximum demand indicator (maximum 15-min average power consumption recorded this month).
|
||||
EOF
|
||||
|
||||
if [ "$?" = "0" ]
|
||||
|
|
Ładowanie…
Reference in New Issue