kopia lustrzana https://github.com/weetmuts/wmbusmeters
Added new driver vario451mid heat meter.
rodzic
9238d89245
commit
ade1154715
|
|
@ -0,0 +1,123 @@
|
|||
/*
|
||||
Copyright (C) 2022 Fredrik Öhrström (gpl-3.0-or-later)
|
||||
|
||||
This program is free software: you can redistribute it and/or modify
|
||||
it under the terms of the GNU General Public License as published by
|
||||
the Free Software Foundation, either version 3 of the License, or
|
||||
(at your option) any later version.
|
||||
|
||||
This program is distributed in the hope that it will be useful,
|
||||
but WITHOUT ANY WARRANTY; without even the implied warranty of
|
||||
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
||||
GNU General Public License for more details.
|
||||
|
||||
You should have received a copy of the GNU General Public License
|
||||
along with this program. If not, see <http://www.gnu.org/licenses/>.
|
||||
*/
|
||||
|
||||
#include"meters_common_implementation.h"
|
||||
|
||||
struct MeterVario451Mid : public virtual MeterCommonImplementation
|
||||
{
|
||||
MeterVario451Mid(MeterInfo &mi, DriverInfo &di);
|
||||
|
||||
private:
|
||||
|
||||
double total_energy_consumption_kwh_ {};
|
||||
double energy_at_set_date_kwh_ {};
|
||||
string set_date_txt_;
|
||||
double energy_at_old_date_kwh_ {};
|
||||
string old_date_txt_;
|
||||
};
|
||||
|
||||
static bool ok = registerDriver([](DriverInfo&di)
|
||||
{
|
||||
di.setName("vario451mid");
|
||||
di.setMeterType(MeterType::HeatMeter);
|
||||
// Mode 7
|
||||
di.addLinkMode(LinkMode::T1);
|
||||
di.addDetection(MANUFACTURER_TCH, 0x04, 0x17);
|
||||
di.setConstructor([](MeterInfo& mi, DriverInfo& di){ return shared_ptr<Meter>(new MeterVario451Mid(mi, di)); });
|
||||
});
|
||||
|
||||
MeterVario451Mid::MeterVario451Mid(MeterInfo &mi, DriverInfo &di) : MeterCommonImplementation(mi, di)
|
||||
{
|
||||
addFieldWithExtractor(
|
||||
"total_energy_consumption",
|
||||
Quantity::Energy,
|
||||
NoDifVifKey,
|
||||
VifScaling::Auto,
|
||||
MeasurementType::Instantaneous,
|
||||
ValueInformation::AnyEnergyVIF,
|
||||
StorageNr(0),
|
||||
TariffNr(0),
|
||||
IndexNr(1),
|
||||
PrintProperty::JSON | PrintProperty::FIELD | PrintProperty::IMPORTANT,
|
||||
"The total energy consumption recorded by this meter.",
|
||||
SET_FUNC(total_energy_consumption_kwh_, Unit::KWH),
|
||||
GET_FUNC(total_energy_consumption_kwh_, Unit::KWH));
|
||||
|
||||
addFieldWithExtractor(
|
||||
"energy_at_old_date",
|
||||
Quantity::Energy,
|
||||
NoDifVifKey,
|
||||
VifScaling::Auto,
|
||||
MeasurementType::Instantaneous,
|
||||
ValueInformation::AnyEnergyVIF,
|
||||
StorageNr(1),
|
||||
TariffNr(0),
|
||||
IndexNr(1),
|
||||
PrintProperty::JSON | PrintProperty::FIELD,
|
||||
"The total energy consumption recorded when?",
|
||||
SET_FUNC(energy_at_old_date_kwh_, Unit::KWH),
|
||||
GET_FUNC(energy_at_old_date_kwh_, Unit::KWH));
|
||||
|
||||
addStringFieldWithExtractor(
|
||||
"old_date",
|
||||
Quantity::Text,
|
||||
NoDifVifKey,
|
||||
MeasurementType::Instantaneous,
|
||||
ValueInformation::Date,
|
||||
StorageNr(1),
|
||||
TariffNr(0),
|
||||
IndexNr(1),
|
||||
PrintProperty::JSON,
|
||||
"The last billing old date?",
|
||||
SET_STRING_FUNC(old_date_txt_),
|
||||
GET_STRING_FUNC(old_date_txt_));
|
||||
|
||||
addFieldWithExtractor(
|
||||
"energy_at_set_date",
|
||||
Quantity::Energy,
|
||||
NoDifVifKey,
|
||||
VifScaling::Auto,
|
||||
MeasurementType::Instantaneous,
|
||||
ValueInformation::AnyEnergyVIF,
|
||||
StorageNr(8),
|
||||
TariffNr(0),
|
||||
IndexNr(1),
|
||||
PrintProperty::JSON | PrintProperty::FIELD,
|
||||
"The total energy consumption recorded by this meter at the due date.",
|
||||
SET_FUNC(energy_at_set_date_kwh_, Unit::KWH),
|
||||
GET_FUNC(energy_at_set_date_kwh_, Unit::KWH));
|
||||
|
||||
addStringFieldWithExtractor(
|
||||
"set_date",
|
||||
Quantity::Text,
|
||||
NoDifVifKey,
|
||||
MeasurementType::Instantaneous,
|
||||
ValueInformation::Date,
|
||||
StorageNr(8),
|
||||
TariffNr(0),
|
||||
IndexNr(1),
|
||||
PrintProperty::JSON,
|
||||
"The last billing set date.",
|
||||
SET_STRING_FUNC(set_date_txt_),
|
||||
GET_STRING_FUNC(set_date_txt_));
|
||||
|
||||
}
|
||||
|
||||
// Test: Heato vario451mid 94430412 NOKEY
|
||||
// telegram=734468501204439417048c0084900f002c2536700000B767B64527c50ac67a33005007102f2f8404062846000082046c9f2c8d04861f1e72fe00000000000000000000000000000000000000000000000000000000440600000000426cffff0406c94700002f2f2f2f2f2f2f2f2f2f2f2f2f2f2f
|
||||
// {"media":"heat","meter":"vario451mid","name":"Heato","id":"94430412","total_energy_consumption_kwh":18377,"energy_at_old_date_kwh":0,"old_date":"2127-15-31","energy_at_set_date_kwh":17960,"set_date":"2020-12-31","timestamp":"1111-11-11T11:11:11Z"}
|
||||
// |Heato;94430412;18377.000000;0.000000;17960.000000;1111-11-11 11:11.11
|
||||
Ładowanie…