kopia lustrzana https://github.com/weetmuts/wmbusmeters
Accept t1 and c1 as linkmodes for multical21 meters.
rodzic
941318aa54
commit
88d655e66a
|
@ -1,5 +1,5 @@
|
|||
telegram=|2A442D2C998734761B168D2091D37CAC21576C78|02FF207100041308190000441308190000615B7F616713|
|
||||
{"media":"cold water","meter":"multical21","name":"MyTapWater","id":"76348799","total_m3":6.408,"target_m3":6.408,"max_flow_m3h":0,"flow_temperature_c":127,"external_temperature_c":19,"current_status":"DRY","time_dry":"22-31 days","time_reversed":"","time_leaking":"","time_bursting":"","timestamp":"1111-11-11T11:11:11Z"}
|
||||
|
||||
telegram=|6E4401062020202005077A9A006085|2F2F0F0A734393CC0000435B0183001A54E06F630291342510030F00007B013E0B00003E0B00003E0B00003E0B00003E0B00003E0B00003E0B0000650000003D0000003D0000003D00000000000000A0910CB003FFFFFFFFFFFFFFFFFFFFA62B|
|
||||
{"media":"water","meter":"apator162","name":"Wasser","id":"20202020","total_m3":3.843,"timestamp":"1111-11-11T11:11:11Z"}
|
||||
telegram=|A244EE4D785634123C067A8F000000|0C1348550000426CE1F14C130000000082046C21298C0413330000008D04931E3A3CFE3300000033000000330000003300000033000000330000003300000033000000330000003300000033000000330000004300000034180000046D0D0B5C2B03FD6C5E150082206C5C290BFD0F0200018C4079678885238310FD3100000082106C01018110FD610002FD66020002FD170000|
|
||||
{"media":"warm water","meter":"supercom587","name":"MyWarmWater","id":"12345678","total_m3":5.548,"timestamp":"1111-11-11T11:11:11Z"}
|
||||
|
|
|
@ -49,7 +49,7 @@
|
|||
X(lansendw, T1_bit, DoorWindow, LANSENDW, LansenDW) \
|
||||
X(lansenpu, T1_bit, Pulse, LANSENPU, LansenPU) \
|
||||
X(mkradio3, T1_bit, Water, MKRADIO3, MKRadio3) \
|
||||
X(multical21, C1_bit, Water, MULTICAL21, Multical21) \
|
||||
X(multical21, C1_bit|T1_bit, Water, MULTICAL21, Multical21) \
|
||||
X(multical302,C1_bit, Heat, MULTICAL302, Multical302) \
|
||||
X(multical403,C1_bit, Heat, MULTICAL403, Multical403) \
|
||||
X(multical603,C1_bit, Heat, MULTICAL603, Multical603) \
|
||||
|
|
|
@ -13,8 +13,9 @@ TESTRESULT="ERROR"
|
|||
cat simulations/simulation_t1_and_c1.txt | grep '^{' > $TEST/test_expected.txt
|
||||
$PROG --format=json --listento=c1,t1 simulations/simulation_t1_and_c1.txt \
|
||||
MyTapWater multical21:c1 76348799 "" \
|
||||
Wasser apator162:t1 20202020 "" \
|
||||
> $TEST/test_output.txt
|
||||
MyWarmWater supercom587:t1 12345678 "" \
|
||||
> $TEST/test_output.txt
|
||||
|
||||
if [ "$?" = "0" ]
|
||||
then
|
||||
cat $TEST/test_output.txt | sed 's/"timestamp":"....-..-..T..:..:..Z"/"timestamp":"1111-11-11T11:11:11Z"/' > $TEST/test_responses.txt
|
||||
|
@ -23,6 +24,10 @@ then
|
|||
then
|
||||
echo "OK: $TESTNAME"
|
||||
TESTRESULT="OK"
|
||||
else
|
||||
echo ERROR: $TESTNAME
|
||||
diff $TEST/test_expected.txt $TEST/test_responses.txt
|
||||
exit 1
|
||||
fi
|
||||
fi
|
||||
|
||||
|
@ -30,9 +35,9 @@ if [ "$TESTRESULT" = "ERROR" ]; then echo ERROR: $TESTNAME; exit 1; fi
|
|||
|
||||
MSG=$($PROG --listento=c1,t1 simulations/simulation_t1_and_c1.txt \
|
||||
MyTapWater multical21:c1 76348799 "" \
|
||||
Wasser apator162:s1 20202020 "")
|
||||
MyWarmWater supercom587:c1 12345678 "")
|
||||
|
||||
if [ "$MSG" != "(cmdline) cannot set link modes to: s1 because meter apator162 only transmits on: c1,t1" ]
|
||||
if [ "$MSG" != "(cmdline) cannot set link modes to: c1 because meter supercom587 only transmits on: t1" ]
|
||||
then
|
||||
echo ERROR: $TESTNAME
|
||||
echo Did not expect: $MSG
|
||||
|
@ -41,14 +46,14 @@ else
|
|||
echo "OK: $TESTNAME"
|
||||
fi
|
||||
|
||||
TESTNAME="Test that setting multical21 to t1 fails"
|
||||
TESTNAME="Test that setting supercom587 to c1 fails"
|
||||
TESTRESULT="ERROR"
|
||||
|
||||
MSG=$($PROG --listento=c1,t1 --usestdoutforlog simulations/simulation_t1_and_c1.txt \
|
||||
MyTapWater multical21:t1 76348799 "" \
|
||||
Wasser apator162:c1 20202020 "")
|
||||
MyTapWater multical21:c1 76348799 "" \
|
||||
MyWarmWater supercom587:c1 12345678 "")
|
||||
|
||||
if [ "$MSG" != "(cmdline) cannot set link modes to: t1 because meter multical21 only transmits on: c1" ]
|
||||
if [ "$MSG" != "(cmdline) cannot set link modes to: c1 because meter supercom587 only transmits on: t1" ]
|
||||
then
|
||||
echo ERROR: $TESTNAME
|
||||
echo Did not expect: $MSG
|
||||
|
|
Ładowanie…
Reference in New Issue