kopia lustrzana https://github.com/weetmuts/wmbusmeters
amiplus - add maximum power consumption field. This is calculated as the maximum value of 15-minute consumption averages, reset on 1st of each month. If the calculated max power consumption exceeds the value on the contract with power company, the end user will pay penalty fees.
rodzic
c865e88ccf
commit
6729d46957
|
@ -30,13 +30,13 @@ telegram=|1844AE4C4455223368077A55000000_041389E20100023B0000|
|
|||
|
||||
telegram=|4E4401061010101002027A00004005_2F2F0E035040691500000B2B300300066D00790C7423400C78371204860BABC8FC100000000E833C8074000000000BAB3C0000000AFDC9FC0136022F2F2F2F2F|
|
||||
{"media":"electricity","meter":"amiplus","name":"MyElectricity1","id":"10101010","total_energy_consumption_kwh":15694.05,"current_power_consumption_kw":0.33,"total_energy_production_kwh":7.48,"current_power_production_kw":0,"voltage_at_phase_1_v":236,"device_date_time":"2019-03-20 12:57:00","timestamp":"1111-11-11T11:11:11Z"}
|
||||
|MyElectricity1;10101010;15694.05;0.33;7.48;0;236;null;null;null;null;null;null;null;null;1111-11-11 11:11.11
|
||||
|MyElectricity1;10101010;15694.05;0.33;7.48;0;236;null;null;null;null;null;null;null;null;null;1111-11-11 11:11.11
|
||||
|
||||
# Test amiplus/apator electricity meter with three phase voltages
|
||||
|
||||
telegram=|5E44B6105843250000027A2A005005_2F2F0C7835221400066D404708AC2A400E032022650900000E833C0000000000001B2B9647000B2B5510000BAB3C0000000AFDC9FC0135020AFDC9FC0245020AFDC9FC0339020BABC8FC100000002F2F|
|
||||
{"media":"electricity","meter":"amiplus","name":"MyElectricity2","id":"00254358","total_energy_consumption_kwh":9652.22,"current_power_consumption_kw":1.055,"total_energy_production_kwh":0,"current_power_production_kw":0,"voltage_at_phase_1_v":235,"voltage_at_phase_2_v":245,"voltage_at_phase_3_v":239,"device_date_time":"2021-10-12 08:07:00","timestamp":"1111-11-11T11:11:11Z"}
|
||||
|MyElectricity2;00254358;9652.22;1.055;0;0;235;245;239;null;null;null;null;null;null;1111-11-11 11:11.11
|
||||
{"media":"electricity","meter":"amiplus","name":"MyElectricity2","id":"00254358","total_energy_consumption_kwh":9652.22,"current_power_consumption_kw":1.055,"total_energy_production_kwh":0,"current_power_production_kw":0,"voltage_at_phase_1_v":235,"voltage_at_phase_2_v":245,"voltage_at_phase_3_v":239,"max_power_consumption_kw":4.796,"device_date_time":"2021-10-12 08:07:00","timestamp":"1111-11-11T11:11:11Z"}
|
||||
|MyElectricity2;00254358;9652.22;1.055;0;0;235;245;239;null;null;null;null;null;null;4.796;1111-11-11 11:11.11
|
||||
|
||||
|
||||
# Test MKRadio3 T1 telegrams
|
||||
|
|
|
@ -27,7 +27,7 @@ namespace
|
|||
static bool ok = registerDriver([](DriverInfo&di)
|
||||
{
|
||||
di.setName("amiplus");
|
||||
di.setDefaultFields("name,id,total_energy_consumption_kwh,current_power_consumption_kw,total_energy_production_kwh,current_power_production_kw,voltage_at_phase_1_v,voltage_at_phase_2_v,voltage_at_phase_3_v,total_energy_consumption_tariff_1_kwh,total_energy_consumption_tariff_2_kwh,total_energy_consumption_tariff_3_kwh,total_energy_production_tariff_1_kwh,total_energy_production_tariff_2_kwh,total_energy_production_tariff_3_kwh,timestamp");
|
||||
di.setDefaultFields("name,id,total_energy_consumption_kwh,current_power_consumption_kw,total_energy_production_kwh,current_power_production_kw,voltage_at_phase_1_v,voltage_at_phase_2_v,voltage_at_phase_3_v,total_energy_consumption_tariff_1_kwh,total_energy_consumption_tariff_2_kwh,total_energy_consumption_tariff_3_kwh,total_energy_production_tariff_1_kwh,total_energy_production_tariff_2_kwh,total_energy_production_tariff_3_kwh,max_power_consumption_kw,timestamp");
|
||||
di.setMeterType(MeterType::ElectricityMeter);
|
||||
di.addLinkMode(LinkMode::T1);
|
||||
di.addDetection(MANUFACTURER_APA, 0x02, 0x02);
|
||||
|
@ -184,22 +184,34 @@ namespace
|
|||
FieldMatcher::build()
|
||||
.set(DifVifKey("8E30833C"))
|
||||
);
|
||||
|
||||
addNumericFieldWithExtractor(
|
||||
"max_power_consumption",
|
||||
"The maximum demand indicator (maximum 15-min average power consumption recorded this month).",
|
||||
DEFAULT_PRINT_PROPERTIES,
|
||||
Quantity::Power,
|
||||
VifScaling::Auto,
|
||||
FieldMatcher::build()
|
||||
.set(MeasurementType::Maximum)
|
||||
.set(VIFRange::AnyPowerVIF)
|
||||
);
|
||||
|
||||
}
|
||||
}
|
||||
|
||||
// Test: MyElectricity1 amiplus 10101010 NOKEY
|
||||
// telegram=|4E4401061010101002027A00004005_2F2F0E035040691500000B2B300300066D00790C7423400C78371204860BABC8FC100000000E833C8074000000000BAB3C0000000AFDC9FC0136022F2F2F2F2F|
|
||||
// {"media":"electricity","meter":"amiplus","name":"MyElectricity1","id":"10101010","total_energy_consumption_kwh":15694.05,"current_power_consumption_kw":0.33,"total_energy_production_kwh":7.48,"current_power_production_kw":0,"voltage_at_phase_1_v":236,"device_date_time":"2019-03-20 12:57:00","timestamp":"1111-11-11T11:11:11Z"}
|
||||
// |MyElectricity1;10101010;15694.05;0.33;7.48;0;236;null;null;null;null;null;null;null;null;1111-11-11 11:11.11
|
||||
// |MyElectricity1;10101010;15694.05;0.33;7.48;0;236;null;null;null;null;null;null;null;null;null;1111-11-11 11:11.11
|
||||
|
||||
// Test: MyElectricity2 amiplus 00254358 NOKEY
|
||||
// Comment: amiplus/apator electricity meter with three phase voltages
|
||||
// telegram=|5E44B6105843250000027A2A005005_2F2F0C7835221400066D404708AC2A400E032022650900000E833C0000000000001B2B9647000B2B5510000BAB3C0000000AFDC9FC0135020AFDC9FC0245020AFDC9FC0339020BABC8FC100000002F2F|
|
||||
// {"media":"electricity","meter":"amiplus","name":"MyElectricity2","id":"00254358","total_energy_consumption_kwh":9652.22,"current_power_consumption_kw":1.055,"total_energy_production_kwh":0,"current_power_production_kw":0,"voltage_at_phase_1_v":235,"voltage_at_phase_2_v":245,"voltage_at_phase_3_v":239,"device_date_time":"2021-10-12 08:07:00","timestamp":"1111-11-11T11:11:11Z"}
|
||||
// |MyElectricity2;00254358;9652.22;1.055;0;0;235;245;239;null;null;null;null;null;null;1111-11-11 11:11.11
|
||||
// {"media":"electricity","meter":"amiplus","name":"MyElectricity2","id":"00254358","total_energy_consumption_kwh":9652.22,"current_power_consumption_kw":1.055,"total_energy_production_kwh":0,"current_power_production_kw":0,"voltage_at_phase_1_v":235,"voltage_at_phase_2_v":245,"voltage_at_phase_3_v":239,"max_power_consumption_kw":4.796,"device_date_time":"2021-10-12 08:07:00","timestamp":"1111-11-11T11:11:11Z"}
|
||||
// |MyElectricity2;00254358;9652.22;1.055;0;0;235;245;239;null;null;null;null;null;null;4.796;1111-11-11 11:11.11
|
||||
|
||||
// Test: MyElectricity3 amiplus 86064864 NOKEY
|
||||
// Comment: amiplus/apator electricity meter with three phase voltages and 2 tariffs.
|
||||
// telegram=|804401066448068602027A000070052F2F_066D1E5C11DA21400C78644806868E10036110012500008E20038106531800008E10833C9949000000008E20833C8606000000001B2B5228020B2B3217000BAB3C0000000AFDC9FC0131020AFDC9FC0225020AFDC9FC0331020BABC8FC100000002F2F2F2F2F2F2F2F2F2F2F2F2FDE47|
|
||||
// {"media":"electricity","meter":"amiplus","name":"MyElectricity3","id":"86064864","current_power_consumption_kw":1.732,"current_power_production_kw":0,"voltage_at_phase_1_v":231,"voltage_at_phase_2_v":225,"voltage_at_phase_3_v":231,"device_date_time":"2022-01-26 17:28:30","total_energy_consumption_tariff_1_kwh":25011.061,"total_energy_consumption_tariff_2_kwh":18530.681,"total_energy_production_tariff_1_kwh":4.999,"total_energy_production_tariff_2_kwh":0.686,"timestamp":"1111-11-11T11:11:11Z"}
|
||||
// |MyElectricity3;86064864;null;1.732;null;0;231;225;231;25011.061;18530.681;null;4.999;0.686;null;1111-11-11 11:11.11
|
||||
// {"media":"electricity","meter":"amiplus","name":"MyElectricity3","id":"86064864","current_power_consumption_kw":1.732,"current_power_production_kw":0,"voltage_at_phase_1_v":231,"voltage_at_phase_2_v":225,"voltage_at_phase_3_v":231,"device_date_time":"2022-01-26 17:28:30","total_energy_consumption_tariff_1_kwh":25011.061,"total_energy_consumption_tariff_2_kwh":18530.681,"total_energy_production_tariff_1_kwh":4.999,"total_energy_production_tariff_2_kwh":0.686,"max_power_consumption_kw":22.852,"timestamp":"1111-11-11T11:11:11Z"}
|
||||
// |MyElectricity3;86064864;null;1.732;null;0;231;225;231;25011.061;18530.681;null;4.999;0.686;null;22.852;1111-11-11 11:11.11
|
||||
|
|
|
@ -36,6 +36,7 @@ METER_TOTAL_ENERGY_CONSUMPTION_TARIFF_3_KWH
|
|||
METER_TOTAL_ENERGY_PRODUCTION_TARIFF_1_KWH
|
||||
METER_TOTAL_ENERGY_PRODUCTION_TARIFF_2_KWH
|
||||
METER_TOTAL_ENERGY_PRODUCTION_TARIFF_3_KWH
|
||||
METER_MAX_POWER_CONSUMPTION_KW
|
||||
EOF
|
||||
|
||||
if [ "$?" = "0" ]
|
||||
|
@ -86,6 +87,7 @@ total_energy_consumption_tariff_3_kwh The total energy consumption recorded by
|
|||
total_energy_production_tariff_1_kwh The total energy production recorded by this meter on tariff 1.
|
||||
total_energy_production_tariff_2_kwh The total energy production recorded by this meter on tariff 2.
|
||||
total_energy_production_tariff_3_kwh The total energy production recorded by this meter on tariff 3.
|
||||
max_power_consumption_kw The maximum demand indicator (maximum 15-min average power consumption recorded this month).
|
||||
EOF
|
||||
|
||||