Added Techem Compact V heatmeter

pull/139/head
IzeQube 2020-07-26 14:40:25 +02:00
rodzic 01168aeae3
commit 5fd9d3a4f5
4 zmienionych plików z 132 dodań i 0 usunięć

Wyświetl plik

@ -115,6 +115,7 @@ METER_OBJS:=\
$(BUILD)/meter_apator08.o \
$(BUILD)/meter_apator162.o \
$(BUILD)/meter_cma12w.o \
$(BUILD)/meter_compact5.o \
$(BUILD)/meter_ebzwmbe.o \
$(BUILD)/meter_ehzp.o \
$(BUILD)/meter_esyswm.o \

Wyświetl plik

@ -220,6 +220,7 @@ Innotas EurisII (eurisii)
Techem FHKV data II/III (fhkvdataiii)
Supported heat meter:
Heat meter Techem Compact V (compact5) (non-standard protocol)
Heat meter Techem Vario 4 (vario451) (non-standard protocol)
Heat meter Kamstrup Multical 302 (multical302) (in C1 mode, please open issue for T1 mode)

Wyświetl plik

@ -0,0 +1,128 @@
/*
Copyright (C) 2019 Fredrik Öhrström
This program is free software: you can redistribute it and/or modify
it under the terms of the GNU General Public License as published by
the Free Software Foundation, either version 3 of the License, or
(at your option) any later version.
This program is distributed in the hope that it will be useful,
but WITHOUT ANY WARRANTY; without even the implied warranty of
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
GNU General Public License for more details.
You should have received a copy of the GNU General Public License
along with this program. If not, see <http://www.gnu.org/licenses/>.
*/
#include"dvparser.h"
#include"meters.h"
#include"meters_common_implementation.h"
#include"wmbus.h"
#include"wmbus_utils.h"
#include"units.h"
#include"util.h"
struct MeterCompact5 : public virtual HeatMeter, public virtual MeterCommonImplementation
{
MeterCompact5(WMBus *bus, MeterInfo &mi);
double totalEnergyConsumption(Unit u);
double currentPeriodEnergyConsumption(Unit u);
double previousPeriodEnergyConsumption(Unit u);
private:
void processContent(Telegram *t);
double total_energy_kwh_ {};
double curr_energy_kwh_ {};
double prev_energy_kwh_ {};
};
unique_ptr<HeatMeter> createCompact5(WMBus *bus, MeterInfo &mi)
{
return unique_ptr<HeatMeter>(new MeterCompact5(bus, mi));
}
MeterCompact5::MeterCompact5(WMBus *bus, MeterInfo &mi) :
MeterCommonImplementation(bus, mi, MeterType::COMPACT5, MANUFACTURER_TCH)
{
addMedia(0x04); // C telegrams
addMedia(0xC3); // T telegrams
addLinkMode(LinkMode::C1);
addLinkMode(LinkMode::T1);
addExpectedVersion(0x45);
addPrint("total", Quantity::Energy,
[&](Unit u){ return totalEnergyConsumption(u); },
"The total energy consumption recorded by this meter.",
true, true);
addPrint("current", Quantity::Energy,
[&](Unit u){ return currentPeriodEnergyConsumption(u); },
"Energy consumption so far in this billing period.",
true, true);
addPrint("previous", Quantity::Energy,
[&](Unit u){ return previousPeriodEnergyConsumption(u); },
"Energy consumption in previous billing period.",
true, true);
}
double MeterCompact5::totalEnergyConsumption(Unit u)
{
assertQuantity(u, Quantity::Energy);
return convert(total_energy_kwh_, Unit::KWH, u);
}
double MeterCompact5::currentPeriodEnergyConsumption(Unit u)
{
assertQuantity(u, Quantity::Energy);
return convert(curr_energy_kwh_, Unit::KWH, u);
}
double MeterCompact5::previousPeriodEnergyConsumption(Unit u)
{
assertQuantity(u, Quantity::Energy);
return convert(prev_energy_kwh_, Unit::KWH, u);
}
void MeterCompact5::processContent(Telegram *t)
{
// Unfortunately, the Techem Compact V is mostly a proprieatary protocol
// simple wrapped inside a wmbus telegram since the ci-field is 0xa2.
// Which means that the entire payload is manufacturer specific.
map<string,pair<int,DVEntry>> vendor_values;
vector<uchar> content;
t->extractPayload(&content);
uchar prev_lo = content[3];
uchar prev_hi = content[4];
double prev = (256.0*prev_hi+prev_lo)/1000;
string prevs;
strprintf(prevs, "%02x%02x", prev_lo, prev_hi);
int offset = t->parsed.size()+3;
vendor_values["0215"] = { offset, DVEntry(MeasurementType::Instantaneous, 0x15, 0, 0, 0, prevs) };
t->explanations.push_back({ offset, prevs });
t->addMoreExplanation(offset, " energy used in previous billing period (%f KWH)", prev);
uchar curr_lo = content[7];
uchar curr_hi = content[8];
double curr = (256.0*curr_hi+curr_lo)/1000;
string currs;
strprintf(currs, "%02x%02x", curr_lo, curr_hi);
offset = t->parsed.size()+7;
vendor_values["0215"] = { offset, DVEntry(MeasurementType::Instantaneous, 0x15, 0, 0, 0, currs) };
t->explanations.push_back({ offset, currs });
t->addMoreExplanation(offset, " energy used in current billing period (%f KWH)", curr);
total_energy_kwh_ = prev+curr;
curr_energy_kwh_ = curr;
prev_energy_kwh_ = prev;
}

Wyświetl plik

@ -30,6 +30,7 @@
X(apator08, T1_bit, Water, APATOR08, Apator08) \
X(apator162, C1_bit|T1_bit, Water, APATOR162, Apator162) \
X(cma12w, C1_bit|T1_bit, TempHygro, CMA12W, CMa12w) \
X(compact5, T1_bit, Heat, COMPACT5, Compact5) \
X(ebzwmbe, T1_bit, Electricity, EBZWMBE, EBZWMBE) \
X(eurisii, T1_bit, HeatCostAllocation, EURISII, EurisII) \
X(ehzp, T1_bit, Electricity, EHZP, EHZP) \
@ -225,6 +226,7 @@ unique_ptr<WaterMeter> createMultical21(WMBus *bus, MeterInfo &m);
unique_ptr<WaterMeter> createFlowIQ3100(WMBus *bus, MeterInfo &m);
unique_ptr<HeatMeter> createMultical302(WMBus *bus, MeterInfo &m);
unique_ptr<HeatMeter> createVario451(WMBus *bus, MeterInfo &m);
unique_ptr<HeatMeter> createCompact5(WMBus *bus, MeterInfo &m);
unique_ptr<WaterMeter> createWaterstarM(WMBus *bus, MeterInfo &m);
unique_ptr<ElectricityMeter> createOmnipower(WMBus *bus, MeterInfo &m);