kopia lustrzana https://github.com/weetmuts/wmbusmeters
extended statuses for sensostar driver+mqtt discov
rodzic
31164236c6
commit
5debd72673
|
@ -172,6 +172,174 @@
|
|||
}
|
||||
},
|
||||
|
||||
"status_ERROR_TEMP_SENSOR_1_CABLE_BREAK": {
|
||||
"component": "binary_sensor",
|
||||
"discovery_payload": {
|
||||
"device": {
|
||||
"identifiers": ["wmbusmeters_{id}"],
|
||||
"manufacturer": "Engelmann",
|
||||
"model": "{driver}",
|
||||
"name": "{name}",
|
||||
"sw_version": "{id}"
|
||||
},
|
||||
"enabled_by_default": true,
|
||||
"device_class": "problem",
|
||||
"name": "{name} status error (Temperature Sensor 1 Cable Break)",
|
||||
"state_topic": "wmbusmeters/{name}",
|
||||
"unique_id": "wmbusmeters_{id}_{attribute}",
|
||||
"value_template": "{{ 'ERROR_TEMP_SENSOR_1_CABLE_BREAK' in value_json.status }}",
|
||||
"payload_on": "True",
|
||||
"payload_off": "False"
|
||||
}
|
||||
},
|
||||
|
||||
"status_ERROR_TEMP_SENSOR_1_SHORT_CIRCUIT": {
|
||||
"component": "binary_sensor",
|
||||
"discovery_payload": {
|
||||
"device": {
|
||||
"identifiers": ["wmbusmeters_{id}"],
|
||||
"manufacturer": "Engelmann",
|
||||
"model": "{driver}",
|
||||
"name": "{name}",
|
||||
"sw_version": "{id}"
|
||||
},
|
||||
"enabled_by_default": true,
|
||||
"device_class": "problem",
|
||||
"name": "{name} status error (Temperature Sensor 1 Short Circuit)",
|
||||
"state_topic": "wmbusmeters/{name}",
|
||||
"unique_id": "wmbusmeters_{id}_{attribute}",
|
||||
"value_template": "{{ 'ERROR_TEMP_SENSOR_1_SHORT_CIRCUIT' in value_json.status }}",
|
||||
"payload_on": "True",
|
||||
"payload_off": "False"
|
||||
}
|
||||
},
|
||||
|
||||
"status_ERROR_TEMP_SENSOR_2_CABLE_BREAK": {
|
||||
"component": "binary_sensor",
|
||||
"discovery_payload": {
|
||||
"device": {
|
||||
"identifiers": ["wmbusmeters_{id}"],
|
||||
"manufacturer": "Engelmann",
|
||||
"model": "{driver}",
|
||||
"name": "{name}",
|
||||
"sw_version": "{id}"
|
||||
},
|
||||
"enabled_by_default": true,
|
||||
"device_class": "problem",
|
||||
"name": "{name} status error (Temperature Sensor 2 Cable Break)",
|
||||
"state_topic": "wmbusmeters/{name}",
|
||||
"unique_id": "wmbusmeters_{id}_{attribute}",
|
||||
"value_template": "{{ 'ERROR_TEMP_SENSOR_2_CABLE_BREAK' in value_json.status }}",
|
||||
"payload_on": "True",
|
||||
"payload_off": "False"
|
||||
}
|
||||
},
|
||||
|
||||
"status_ERROR_TEMP_SENSOR_2_SHORT_CIRCUIT": {
|
||||
"component": "binary_sensor",
|
||||
"discovery_payload": {
|
||||
"device": {
|
||||
"identifiers": ["wmbusmeters_{id}"],
|
||||
"manufacturer": "Engelmann",
|
||||
"model": "{driver}",
|
||||
"name": "{name}",
|
||||
"sw_version": "{id}"
|
||||
},
|
||||
"enabled_by_default": true,
|
||||
"device_class": "problem",
|
||||
"name": "{name} status error (Temperature Sensor 2 Short Circuit)",
|
||||
"state_topic": "wmbusmeters/{name}",
|
||||
"unique_id": "wmbusmeters_{id}_{attribute}",
|
||||
"value_template": "{{ 'ERROR_TEMP_SENSOR_2_SHORT_CIRCUIT' in value_json.status }}",
|
||||
"payload_on": "True",
|
||||
"payload_off": "False"
|
||||
}
|
||||
},
|
||||
|
||||
"status_ERROR_FLOW_MEASUREMENT_SYSTEM_ERROR": {
|
||||
"component": "binary_sensor",
|
||||
"discovery_payload": {
|
||||
"device": {
|
||||
"identifiers": ["wmbusmeters_{id}"],
|
||||
"manufacturer": "Engelmann",
|
||||
"model": "{driver}",
|
||||
"name": "{name}",
|
||||
"sw_version": "{id}"
|
||||
},
|
||||
"enabled_by_default": true,
|
||||
"device_class": "problem",
|
||||
"name": "{name} status error (Flow Management System)",
|
||||
"state_topic": "wmbusmeters/{name}",
|
||||
"unique_id": "wmbusmeters_{id}_{attribute}",
|
||||
"value_template": "{{ 'ERROR_FLOW_MEASUREMENT_SYSTEM_ERROR' in value_json.status }}",
|
||||
"payload_on": "True",
|
||||
"payload_off": "False"
|
||||
}
|
||||
},
|
||||
|
||||
"status_ERROR_ELECTRONICS_DEFECT": {
|
||||
"component": "binary_sensor",
|
||||
"discovery_payload": {
|
||||
"device": {
|
||||
"identifiers": ["wmbusmeters_{id}"],
|
||||
"manufacturer": "Engelmann",
|
||||
"model": "{driver}",
|
||||
"name": "{name}",
|
||||
"sw_version": "{id}"
|
||||
},
|
||||
"enabled_by_default": true,
|
||||
"device_class": "problem",
|
||||
"name": "{name} status error (Electronics Defective)",
|
||||
"state_topic": "wmbusmeters/{name}",
|
||||
"unique_id": "wmbusmeters_{id}_{attribute}",
|
||||
"value_template": "{{ 'ERROR_ELECTRONICS_DEFECT' in value_json.status }}",
|
||||
"payload_on": "True",
|
||||
"payload_off": "False"
|
||||
}
|
||||
},
|
||||
|
||||
"status_OK_INSTRUMENT_RESET": {
|
||||
"component": "binary_sensor",
|
||||
"discovery_payload": {
|
||||
"device": {
|
||||
"identifiers": ["wmbusmeters_{id}"],
|
||||
"manufacturer": "Engelmann",
|
||||
"model": "{driver}",
|
||||
"name": "{name}",
|
||||
"sw_version": "{id}"
|
||||
},
|
||||
"enabled_by_default": true,
|
||||
"device_class": "problem",
|
||||
"name": "{name} status OK (instrument reset)",
|
||||
"state_topic": "wmbusmeters/{name}",
|
||||
"unique_id": "wmbusmeters_{id}_{attribute}",
|
||||
"value_template": "{{ 'OK_INSTRUMENT_RESET' in value_json.status }}",
|
||||
"payload_on": "True",
|
||||
"payload_off": "False"
|
||||
}
|
||||
},
|
||||
|
||||
"status_OK_BATTERY_LOW": {
|
||||
"component": "binary_sensor",
|
||||
"discovery_payload": {
|
||||
"device": {
|
||||
"identifiers": ["wmbusmeters_{id}"],
|
||||
"manufacturer": "Engelmann",
|
||||
"model": "{driver}",
|
||||
"name": "{name}",
|
||||
"sw_version": "{id}"
|
||||
},
|
||||
"enabled_by_default": true,
|
||||
"device_class": "problem",
|
||||
"name": "{name} status OK (battery low)",
|
||||
"state_topic": "wmbusmeters/{name}",
|
||||
"unique_id": "wmbusmeters_{id}_{attribute}",
|
||||
"value_template": "{{ 'OK_BATTERY_LOW' in value_json.status }}",
|
||||
"payload_on": "True",
|
||||
"payload_off": "False"
|
||||
}
|
||||
},
|
||||
|
||||
"meter_timestamp": {
|
||||
"component": "sensor",
|
||||
"discovery_payload": {
|
||||
|
|
|
@ -158,9 +158,15 @@ namespace
|
|||
0xff,
|
||||
"OK",
|
||||
{
|
||||
/* What are the bits? If a bit is known then add for example:
|
||||
{ 0x01, "OVERHEAT" }
|
||||
*/
|
||||
// based on information published here: https://www.engelmann.de/wp-content/uploads/2022/10/1080621004_2022-10-12_BA_S3_ES_Comm_en.pdf
|
||||
{ 0x01 , "ERROR_TEMP_SENSOR_1_CABLE_BREAK" },
|
||||
{ 0x02 , "ERROR_TEMP_SENSOR_1_SHORT_CIRCUIT" },
|
||||
{ 0x04 , "ERROR_TEMP_SENSOR_2_CABLE_BREAK" },
|
||||
{ 0x08 , "ERROR_TEMP_SENSOR_2_SHORT_CIRCUIT" },
|
||||
{ 0x10 , "ERROR_FLOW_MEASUREMENT_SYSTEM_ERROR" },
|
||||
{ 0x20 , "ERROR_ELECTRONICS_DEFECT" },
|
||||
{ 0x40 , "OK_INSTRUMENT_RESET" },
|
||||
{ 0x80 , "OK_BATTERY_LOW" },
|
||||
}
|
||||
},
|
||||
},
|
||||
|
@ -172,4 +178,4 @@ namespace
|
|||
// Comment:
|
||||
// telegram=|68B3B36808007257004820c51400046c100000047839803801040600000000041300000000042B00000000142B00000000043B00000000143B00000000025B1400025f15000261daff02235c00046d2c2ddc24440600000000441300000000426c000001fd171003fd0c05000084200600000000c420060000000084300600000000c430060000000084401300000000c44013000000008480401300000000c48040130000000084c0401300000000c4c0401300000000a216|
|
||||
// {"media":"heat","meter":"sensostar","name":"Heat","id":"20480057","meter_timestamp":"2022-04-28 13:44","total_kwh":0,"power_kw":0,"power_max_kw":0,"flow_water_m3h":0,"flow_water_max_m3h":0,"forward_c":20,"return_c":21,"difference_c":-0.38,"total_water_m3":0,"current_status":"ERROR_FLAGS_10","timestamp":"1111-11-11T11:11:11Z"}
|
||||
// |Heat;20480057;0.000000;0.000000;ERROR_FLAGS_10;1111-11-11 11:11.11
|
||||
// |Heat;20480057;0.000000;0.000000;ERROR_FLOW_MEASUREMENT_SYSTEM_ERROR;1111-11-11 11:11.11
|
||||
|
|