kopia lustrzana https://github.com/weetmuts/wmbusmeters
Added test case for unismart gas meter.
rodzic
61dbc60fa7
commit
3e64ba587c
2
CHANGES
2
CHANGES
|
@ -1,4 +1,6 @@
|
|||
|
||||
Added support for the Apator uniSMART gas meter.
|
||||
|
||||
You can now decode a telegram just by supplying hex on the command line:
|
||||
wmbusmeters --format=json <hex_string> MyMeter auto 12345678 NOKEY
|
||||
or just
|
||||
|
|
|
@ -388,6 +388,10 @@ Tauron Amiplus (amiplus) (includes vendor apator and echelon)
|
|||
Gavazzi EM24 (em24)
|
||||
Gransystems 301 and 303 (gransystems)
|
||||
Kamstrup Omnipower (omnipower)
|
||||
|
||||
Support gas meters:
|
||||
uniSMART (unismart)
|
||||
|
||||
```
|
||||
|
||||
The wmbus dongle im871a can listen to either s1, c1 or t1.
|
||||
|
|
|
@ -270,3 +270,8 @@ telegram=|19442423850798160018A2410100133EBBD44081053F243A82A3|
|
|||
telegram=76442104710007612507727100076121042507B5006005E2E95A3C2A1279A5415E6732679B43369FD5FDDDD783EEEBB48236D34E7C94AF0A18A5FDA5F7D64111EB42D4D891622139F2952F9D12A20088DFA4CF8123871123EE1F6C1DCEA414879DDB4E05E508F1826D7EFBA6964DF804C9261EA23BBF03
|
||||
{"media":"water","meter":"aventieswm","name":"Votten","id":"61070071","total_m3":466.472,"consumption_at_set_date_1_m3":465.96,"consumption_at_set_date_2_m3":458.88,"consumption_at_set_date_3_m3":449.65,"consumption_at_set_date_4_m3":442.35,"consumption_at_set_date_5_m3":431.07,"consumption_at_set_date_6_m3":423.98,"consumption_at_set_date_7_m3":415.23,"consumption_at_set_date_8_m3":409.03,"consumption_at_set_date_9_m3":400.79,"consumption_at_set_date_10_m3":393.2,"consumption_at_set_date_11_m3":388.63,"consumption_at_set_date_12_m3":379.26,"consumption_at_set_date_13_m3":371.26,"consumption_at_set_date_14_m3":357.84,"error_flags":"","timestamp":"1111-11-11T11:11:11Z"}
|
||||
|Votten;61070071;466.472000;;1111-11-11 11:11.11
|
||||
|
||||
# Test Unismart Gas Meter
|
||||
telegram=|6044B8059430040001037A1D005085E2B670BCF1A5C87E0C1A51DA18924EF984613DA2A9CD39D8F4C7208326C76D42DBEADF80D574192B71BD7C4F56A7F1513151768A9DB804883B28CB085CA2D0F7438C361CB9E2734712ED9BFBB2A14EF55208|
|
||||
{"media":"gas","meter":"unismart","name":"GasMeter","id":"00043094","total_m3":917,"timestamp":"1111-11-11T11:11:11Z"}
|
||||
|GasMeter;00043094;917.000000;1111-11-11 11:11.11
|
||||
|
|
|
@ -58,7 +58,62 @@ MeterUnismart::MeterUnismart(MeterInfo &mi) :
|
|||
|
||||
void MeterUnismart::processContent(Telegram *t)
|
||||
{
|
||||
int offset;
|
||||
/*
|
||||
(unismart) 11: 0C dif (8 digit BCD Instantaneous value)
|
||||
(unismart) 12: 78 vif (Fabrication no)
|
||||
(unismart) 13: 96221603
|
||||
(unismart) 17: 04 dif (32 Bit Integer/Binary Instantaneous value)
|
||||
(unismart) 18: 6D vif (Date and time type)
|
||||
(unismart) 19: 122DAF29
|
||||
(unismart) 1d: 0C dif (8 digit BCD Instantaneous value)
|
||||
(unismart) 1e: 94 vif (Volume 10⁻² m³)
|
||||
(unismart) 1f: 3A vife (uncorrected meter unit)
|
||||
(unismart) 20: * 00170900 total consumption (917.000000 m3)
|
||||
(unismart) 24: 44 dif (32 Bit Integer/Binary Instantaneous value storagenr=1)
|
||||
(unismart) 25: 6D vif (Date and time type)
|
||||
(unismart) 26: 0026A129
|
||||
(unismart) 2a: 4C dif (8 digit BCD Instantaneous value storagenr=1)
|
||||
(unismart) 2b: 94 vif (Volume 10⁻² m³)
|
||||
(unismart) 2c: 3A vife (uncorrected meter unit)
|
||||
(unismart) 2d: 32110900
|
||||
(unismart) 31: 01 dif (8 Bit Integer/Binary Instantaneous value)
|
||||
(unismart) 32: FD vif (Second extension FD of VIF-codes)
|
||||
(unismart) 33: 67 vife (Special supplier information)
|
||||
(unismart) 34: 00
|
||||
(unismart) 35: 02 dif (16 Bit Integer/Binary Instantaneous value)
|
||||
(unismart) 36: FD vif (Second extension FD of VIF-codes)
|
||||
(unismart) 37: 74 vife (Reserved)
|
||||
(unismart) 38: F00C
|
||||
(unismart) 3a: 0D dif (variable length Instantaneous value)
|
||||
(unismart) 3b: FD vif (Second extension FD of VIF-codes)
|
||||
(unismart) 3c: 0C vife (Model/Version)
|
||||
(unismart) 3d: 06 varlen=6
|
||||
(unismart) 3e: 554747342020
|
||||
(unismart) 44: 01 dif (8 Bit Integer/Binary Instantaneous value)
|
||||
(unismart) 45: FD vif (Second extension FD of VIF-codes)
|
||||
(unismart) 46: 0B vife (Parameter set identification)
|
||||
(unismart) 47: 02
|
||||
(unismart) 48: 01 dif (8 Bit Integer/Binary Instantaneous value)
|
||||
(unismart) 49: 7F vif (Manufacturer specific)
|
||||
(unismart) 4a: 14
|
||||
(unismart) 4b: 06 dif (48 Bit Integer/Binary Instantaneous value)
|
||||
(unismart) 4c: 6D vif (Date and time type)
|
||||
(unismart) 4d: 1E120DAF296D
|
||||
(unismart) 53: 2F skip
|
||||
(unismart) 54: 2F skip
|
||||
(unismart) 55: 2F skip
|
||||
(unismart) 56: 2F skip
|
||||
(unismart) 57: 2F skip
|
||||
(unismart) 58: 2F skip
|
||||
(unismart) 59: 2F skip
|
||||
(unismart) 5a: 2F skip
|
||||
(unismart) 5b: 2F skip
|
||||
(unismart) 5c: 2F skip
|
||||
(unismart) 5d: 2F skip
|
||||
(unismart) 5e: 2F skip
|
||||
|
||||
*/
|
||||
int offset;
|
||||
string key;
|
||||
|
||||
if(findKey(MeasurementType::Unknown, ValueInformation::Volume, 0, 0, &key, &t->values)) {
|
||||
|
|
|
@ -303,6 +303,11 @@ Received telegram from: 61070071
|
|||
type: Water meter (0x07)
|
||||
ver: 0x25
|
||||
driver: aventieswm aventieswm
|
||||
Received telegram from: 00043094
|
||||
manufacturer: (AMX) APATOR METRIX, Poland (0x5b8)
|
||||
type: Gas meter (0x03)
|
||||
ver: 0x01
|
||||
driver: unismart
|
||||
EOF
|
||||
|
||||
RES=$($PROG --logfile=$LOGFILE --t1 simulations/simulation_t1.txt 2>&1)
|
||||
|
|
|
@ -58,7 +58,8 @@ METERS="MyWarmWater supercom587 12345678 NOKEY
|
|||
Heating compact5 62626262 NOKEY
|
||||
Hetta elf 01885619 NOKEY
|
||||
DigiWasser dme_07 93929190 NOKEY
|
||||
Votten aventieswm 61070071 A004EB23329A477F1DD2D7820B56EB3D"
|
||||
Votten aventieswm 61070071 A004EB23329A477F1DD2D7820B56EB3D
|
||||
GasMeter unismart 00043094 00000000000000000000000000000000"
|
||||
|
||||
|
||||
cat simulations/simulation_t1.txt | grep '^{' > $TEST/test_expected.txt
|
||||
|
|
Ładowanie…