kopia lustrzana https://github.com/weetmuts/wmbusmeters
Added type/ver for yet another moronic Izar meter that reports itself as a electric breaker....
rodzic
efd9aaa786
commit
1e94a81183
6
Makefile
6
Makefile
|
@ -175,7 +175,7 @@ all: $(BUILD)/wmbusmeters $(BUILD)/wmbusmeters-admin $(BUILD)/testinternals
|
|||
@$(STRIP_BINARY)
|
||||
@cp $(BUILD)/wmbusmeters $(BUILD)/wmbusmetersd
|
||||
|
||||
dist: wmbusmeters_$(DEBVERSION)_$(DEBARCH).deb
|
||||
deb: wmbusmeters_$(DEBVERSION)_$(DEBARCH).deb
|
||||
|
||||
install: $(BUILD)/wmbusmeters
|
||||
@./install.sh $(BUILD)/wmbusmeters $(DESTDIR) $(EXTRA_INSTALL_OPTIONS)
|
||||
|
@ -193,6 +193,10 @@ wmbusmeters_$(DEBVERSION)_$(DEBARCH).deb:
|
|||
@echo "Maintainer: Fredrik Öhrström" >> $(BUILD)/debian/wmbusmeters/DEBIAN/control
|
||||
@echo "Architecture: $(DEBARCH)" >> $(BUILD)/debian/wmbusmeters/DEBIAN/control
|
||||
@echo "Description: A tool to read wireless mbus telegrams from utility meters." >> $(BUILD)/debian/wmbusmeters/DEBIAN/control
|
||||
@for x in preinst postinst prerm postrm ; do \
|
||||
cp scripts/$$x $(BUILD)/debian/wmbusmeters/DEBIAN/ ; \
|
||||
chmod 555 $(BUILD)/debian/wmbusmeters/DEBIAN/$$x ; \
|
||||
done
|
||||
@(cd $(BUILD)/debian; dpkg-deb --build wmbusmeters .)
|
||||
@mv $(BUILD)/debian/wmbusmeters_$(DEBVERSION)_$(DEBARCH).deb .
|
||||
@echo Built package $@
|
||||
|
|
|
@ -1,3 +1,74 @@
|
|||
#!/bin/sh
|
||||
|
||||
# Start wmbusmeters service
|
||||
|
||||
if [ $(getent group wmbusmeters) ]
|
||||
then
|
||||
echo "group: wmbusmeters unmodified"
|
||||
else
|
||||
groupadd -f wmbusmeters
|
||||
echo "group: added wmbusmeters"
|
||||
fi
|
||||
|
||||
ID=$(id -u wmbusmeters 2>/dev/null)
|
||||
|
||||
if [ -f /usr/sbin/nologin ]
|
||||
then
|
||||
USERSHELL="/usr/sbin/nologin"
|
||||
elif [ -f /sbin/nologin ]
|
||||
then
|
||||
USERSHELL="/sbin/nologin"
|
||||
else
|
||||
USERSHELL="/bin/false"
|
||||
fi
|
||||
|
||||
if [ -z "$ID" ]
|
||||
then
|
||||
# Create the wmbusmeters user
|
||||
useradd --system --shell $USERSHELL -g wmbusmeters wmbusmeters
|
||||
echo "user: added wmbusmeters"
|
||||
else
|
||||
echo "user: wmbusmeters unmodified"
|
||||
fi
|
||||
|
||||
if [ $(getent group dialout) ]
|
||||
then
|
||||
if [ "$(groups wmbusmeters | grep -o dialout)" = "" ]
|
||||
then
|
||||
# Add the wmbusmeters user to dialout
|
||||
usermod -a -G dialout wmbusmeters
|
||||
echo "user: added wmbusmeters to dialout group"
|
||||
else
|
||||
echo "user: wmbusmeters already added to dialout"
|
||||
fi
|
||||
else
|
||||
echo "dialout group does not exist"
|
||||
fi
|
||||
|
||||
if [ $(getent group uucp) ]
|
||||
then
|
||||
if [ "$(groups wmbusmeters | grep -o uucp)" = "" ]
|
||||
then
|
||||
# Add the wmbusmeters user to uucp
|
||||
usermod -a -G uucp wmbusmeters
|
||||
echo "user: added wmbusmeters to uucp group"
|
||||
else
|
||||
echo "user: wmbusmeters already added to uucp"
|
||||
fi
|
||||
else
|
||||
echo "uucp group does not exist"
|
||||
fi
|
||||
|
||||
if [ $(getent group plugdev) ]
|
||||
then
|
||||
if [ "$(groups wmbusmeters | grep -o plugdev)" = "" ]
|
||||
then
|
||||
# Add the wmbusmeters user to plugdev
|
||||
usermod -a -G plugdev wmbusmeters
|
||||
echo "user: added wmbusmeters to plugdev group"
|
||||
else
|
||||
echo user: wmbusmeters already added to plugdev
|
||||
fi
|
||||
else
|
||||
echo "plugdev group does not exist"
|
||||
fi
|
||||
|
|
|
@ -1,3 +1,11 @@
|
|||
#!/bin/bash
|
||||
|
||||
# More cleanup?
|
||||
# More cleanup?
|
||||
|
||||
ID=$(id -u wmbusmeters 2>/dev/null)
|
||||
|
||||
if [ ! "$ID" = "" ]
|
||||
then
|
||||
userdel wmbusmeters
|
||||
echo user: removed wmbusmeters
|
||||
fi
|
||||
|
|
|
@ -1,3 +1,4 @@
|
|||
#!/bin/sh
|
||||
|
||||
# Shutdown wmbusmeters service if it is running.
|
||||
systemctl stop wmbusmeters.service
|
||||
|
|
|
@ -1,3 +1,6 @@
|
|||
#!/bin/bash
|
||||
|
||||
# Stop the service
|
||||
# Stop the service
|
||||
|
||||
echo "Stopping any wmbusmeters.service running..."
|
||||
systemctl stop wmbusmeters.service || true
|
||||
|
|
|
@ -110,6 +110,12 @@ telegram=|2944A511780729662366A20118001378D3B3DB8CEDD77731F25832AAF3DA8CADF9774E
|
|||
{"media":"water","meter":"izar","name":"IzarWater2","id":"66290778","total_m3":16.76,"last_month_total_m3":11.84,"last_month_measure_date":"2019-11-30","remaining_battery_life_y":12,"current_alarms":"no_alarm","previous_alarms":"no_alarm","timestamp":"1111-11-11T11:11:11Z"}
|
||||
|IzarWater2;66290778;16.760000;11.840000;2019-11-30;12.000000;no_alarm;no_alarm;1111-11-11 11:11.11
|
||||
|
||||
# Yet another silly version of IZAR, come again, type 0x20 = Breaker (electricity) for a water meter!
|
||||
|
||||
telegram=|1944A511780779194820A1|21170013355F8EDB2D03C6912B1E37
|
||||
{"media":"water","meter":"izar","name":"IzarWater3","id":"19790778","total_m3":4.366,"last_month_total_m3":0,"last_month_measure_date":"2020-12-31","remaining_battery_life_y":11.5,"current_alarms":"no_alarm","previous_alarms":"no_alarm","timestamp":"1111-11-11T11:11:11Z"}
|
||||
|IzarWater3;19790778;4.366000;0.000000;2020-12-31;11.500000;no_alarm;no_alarm;1111-11-11 11:11.11
|
||||
|
||||
# Test Hydrus water meter telegram
|
||||
telegram=|4E44A5116464646470077AED004005|2F2F01FD08300C13741100007C1300000000FC101300000000FC201300000000726C00000B3B00000002FD748713025A6800C4016D3B177F2ACC011300020000|
|
||||
{"media":"water","meter":"hydrus","name":"HydrusWater","id":"64646464","total_m3":1.174,"max_flow_m3h":0,"flow_temperature_c":10.4,"total_at_date_m3":0.2,"at_date":"2019-10-31 23:59","remaining_battery_life_y":13.686516,"status":"OK","timestamp":"1111-11-11T11:11:11Z"}
|
||||
|
|
|
@ -117,6 +117,7 @@
|
|||
X(IZAR, MANUFACTURER_SAP, 0x66, -1) \
|
||||
X(IZAR, MANUFACTURER_DME, 0x66, -1) \
|
||||
X(IZAR, MANUFACTURER_DME, 0x19, 0x00) \
|
||||
X(IZAR, MANUFACTURER_DME, 0x20, 0x48) \
|
||||
X(IZAR3, MANUFACTURER_SAP, 0x00, 0x88) \
|
||||
X(LANSENSM, MANUFACTURER_LAS, 0x1a, 0x03) \
|
||||
X(LANSENTH, MANUFACTURER_LAS, 0x1b, 0x07) \
|
||||
|
|
|
@ -120,6 +120,11 @@ Received telegram from: 66290778
|
|||
type: Unknown (0x66)
|
||||
ver: 0x23
|
||||
driver: izar
|
||||
Received telegram from: 19790778
|
||||
manufacturer: (DME) DIEHL Metering, Germany (0x11a5)
|
||||
type: Breaker (electricity) (0x20)
|
||||
ver: 0x48
|
||||
driver: izar
|
||||
Received telegram from: 64646464
|
||||
manufacturer: (DME) DIEHL Metering, Germany (0x11a5)
|
||||
type: Water meter (0x07)
|
||||
|
|
|
@ -26,6 +26,7 @@ METERS="MyWarmWater supercom587 12345678 NOKEY
|
|||
Rummet rfmamb 11772288 NOKEY
|
||||
IzarWater izar 21242472 NOKEY
|
||||
IzarWater2 izar 66290778 NOKEY
|
||||
IzarWater3 izar 19790778 NOKEY
|
||||
HydrusWater hydrus 64646464 NOKEY
|
||||
HydrusVater hydrus 65656565 NOKEY
|
||||
HydrodigitWater hydrodigit 86868686 NOKEY
|
||||
|
|
Ładowanie…
Reference in New Issue