2020-04-21 10:40:25 +00:00
|
|
|
#!/bin/sh
|
2019-02-28 16:30:29 +00:00
|
|
|
|
|
|
|
PROG="$1"
|
|
|
|
|
|
|
|
if [ "$PROG" = "" ]
|
|
|
|
then
|
|
|
|
echo Please supply the binary to be tested as the first argument.
|
|
|
|
exit 1
|
|
|
|
fi
|
|
|
|
|
|
|
|
TEST=testoutput
|
|
|
|
LOGFILE=$TEST/logfile
|
2019-04-27 11:31:13 +00:00
|
|
|
LOGFILE_EXPECTED=$TEST/logfile.expected
|
2019-02-28 16:30:29 +00:00
|
|
|
|
2019-11-03 21:00:18 +00:00
|
|
|
TESTNAME="Test listen and print any meter heard in logfile"
|
|
|
|
TESTRESULT="ERROR"
|
|
|
|
|
2019-02-28 16:30:29 +00:00
|
|
|
mkdir -p $TEST
|
|
|
|
rm -f $LOGFILE
|
|
|
|
|
2019-04-27 11:31:13 +00:00
|
|
|
cat > $LOGFILE_EXPECTED <<EOF
|
2019-02-28 16:30:29 +00:00
|
|
|
No meters configured. Printing id:s of all telegrams heard!
|
|
|
|
Received telegram from: 12345678
|
2020-09-04 09:31:49 +00:00
|
|
|
manufacturer: (SON) Sontex, Switzerland (0x4dee)
|
2020-10-11 09:01:10 +00:00
|
|
|
type: Warm Water (30°C-90°C) meter (0x06)
|
|
|
|
ver: 0x3c
|
|
|
|
driver: supercom587
|
2019-02-28 16:30:29 +00:00
|
|
|
Received telegram from: 11111111
|
2020-09-04 09:31:49 +00:00
|
|
|
manufacturer: (SON) Sontex, Switzerland (0x4dee)
|
2020-10-11 09:01:10 +00:00
|
|
|
type: Water meter (0x07)
|
|
|
|
ver: 0x3c
|
|
|
|
driver: supercom587
|
2020-10-31 14:16:14 +00:00
|
|
|
Received telegram from: 27282728
|
|
|
|
manufacturer: (SON) Sontex, Switzerland (0x4dee)
|
|
|
|
type: Heat Cost Allocator (0x08)
|
|
|
|
ver: 0x16
|
|
|
|
driver: sontex868
|
2019-02-28 16:30:29 +00:00
|
|
|
Received telegram from: 12345699
|
2020-09-04 09:31:49 +00:00
|
|
|
manufacturer: (SEN) Sensus Metering Systems, Germany (0x4cae)
|
2020-10-11 09:01:10 +00:00
|
|
|
type: Water meter (0x07)
|
|
|
|
ver: 0x68
|
|
|
|
driver: iperl
|
2019-03-11 16:31:34 +00:00
|
|
|
Received telegram from: 33225544
|
2020-09-04 09:31:49 +00:00
|
|
|
manufacturer: (SEN) Sensus Metering Systems, Germany (0x4cae)
|
2020-10-11 09:01:10 +00:00
|
|
|
type: Water meter (0x07)
|
|
|
|
ver: 0x68
|
|
|
|
driver: iperl
|
2019-03-20 21:16:45 +00:00
|
|
|
Received telegram from: 10101010
|
2020-09-04 09:31:49 +00:00
|
|
|
manufacturer: (APA) Apator, Poland (0x601)
|
2020-10-11 09:01:10 +00:00
|
|
|
type: Electricity meter (0x02)
|
|
|
|
ver: 0x02
|
|
|
|
driver: amiplus
|
2019-04-27 11:31:13 +00:00
|
|
|
Received telegram from: 34333231
|
2020-09-04 09:31:49 +00:00
|
|
|
manufacturer: (TCH) Techem Service (0x5068)
|
2020-10-11 09:01:10 +00:00
|
|
|
type: Warm water (0x62)
|
|
|
|
ver: 0x74
|
|
|
|
driver: mkradio3
|
2019-05-04 06:52:25 +00:00
|
|
|
Received telegram from: 58234965
|
2020-09-04 09:31:49 +00:00
|
|
|
manufacturer: (TCH) Techem Service (0x5068)
|
2020-10-11 09:01:10 +00:00
|
|
|
type: Heat meter (0xc3)
|
|
|
|
ver: 0x27
|
|
|
|
driver: vario451
|
2020-02-12 06:52:29 +00:00
|
|
|
Received telegram from: 11776622
|
2020-09-04 09:31:49 +00:00
|
|
|
manufacturer: (TCH) Techem Service (0x5068)
|
2020-10-11 09:01:10 +00:00
|
|
|
type: Heat Cost Allocator (0x80)
|
|
|
|
ver: 0x69
|
|
|
|
driver: fhkvdataiii
|
2019-05-21 13:18:06 +00:00
|
|
|
Received telegram from: 88018801
|
2020-09-04 09:31:49 +00:00
|
|
|
manufacturer: (INE) INNOTAS Elektronik, Germany (0x25c5)
|
2020-10-11 09:01:10 +00:00
|
|
|
type: Heat Cost Allocator (0x08)
|
|
|
|
ver: 0x55
|
|
|
|
driver: eurisii
|
2020-06-22 08:44:47 +00:00
|
|
|
Received telegram from: 00010204
|
2020-09-04 09:31:49 +00:00
|
|
|
manufacturer: (LAS) Lansen Systems, Sweden (0x3033)
|
2020-10-11 09:01:10 +00:00
|
|
|
type: Smoke detector (0x1a)
|
|
|
|
ver: 0x03
|
|
|
|
driver: lansensm
|
2020-06-22 08:44:47 +00:00
|
|
|
Received telegram from: 00010204
|
2020-09-04 09:31:49 +00:00
|
|
|
manufacturer: (LAS) Lansen Systems, Sweden (0x3033)
|
2020-10-11 09:01:10 +00:00
|
|
|
type: Smoke detector (0x1a)
|
|
|
|
ver: 0x03
|
|
|
|
driver: lansensm
|
2019-10-14 14:53:02 +00:00
|
|
|
Received telegram from: 00010203
|
2020-09-04 09:31:49 +00:00
|
|
|
manufacturer: (LAS) Lansen Systems, Sweden (0x3033)
|
2020-10-11 09:01:10 +00:00
|
|
|
type: Room sensor (eg temperature or humidity) (0x1b)
|
|
|
|
ver: 0x07
|
|
|
|
driver: lansenth
|
2020-06-30 09:29:55 +00:00
|
|
|
Received telegram from: 00010205
|
2020-09-04 09:31:49 +00:00
|
|
|
manufacturer: (LAS) Lansen Systems, Sweden (0x3033)
|
2020-10-11 09:01:10 +00:00
|
|
|
type: Reserved for sensors (0x1d)
|
|
|
|
ver: 0x07
|
|
|
|
driver: lansendw
|
2020-06-30 09:29:55 +00:00
|
|
|
Received telegram from: 00010205
|
2020-09-04 09:31:49 +00:00
|
|
|
manufacturer: (LAS) Lansen Systems, Sweden (0x3033)
|
2020-10-11 09:01:10 +00:00
|
|
|
type: Reserved for sensors (0x1d)
|
|
|
|
ver: 0x07
|
|
|
|
driver: lansendw
|
2020-06-30 14:02:38 +00:00
|
|
|
Received telegram from: 00010206
|
2020-09-04 09:31:49 +00:00
|
|
|
manufacturer: (LAS) Lansen Systems, Sweden (0x3033)
|
2020-10-11 09:01:10 +00:00
|
|
|
type: Other (0x00)
|
|
|
|
ver: 0x14
|
|
|
|
driver: lansenpu
|
2019-10-14 18:26:31 +00:00
|
|
|
Received telegram from: 11772288
|
2020-09-04 09:31:49 +00:00
|
|
|
manufacturer: (BMT) BMETERS, Italy (0x9b4)
|
2020-10-11 09:01:10 +00:00
|
|
|
type: Room sensor (eg temperature or humidity) (0x1b)
|
|
|
|
ver: 0x10
|
|
|
|
driver: rfmamb
|
2019-11-10 07:09:21 +00:00
|
|
|
Received telegram from: 21242472
|
2020-09-04 09:31:49 +00:00
|
|
|
manufacturer: (SAP) Sappel (0x4c30)
|
2020-10-11 09:01:10 +00:00
|
|
|
type: Oil meter (0x01)
|
|
|
|
ver: 0xd4
|
|
|
|
driver: izar
|
2020-02-02 20:31:46 +00:00
|
|
|
Received telegram from: 66290778
|
2020-09-04 09:31:49 +00:00
|
|
|
manufacturer: (DME) DIEHL Metering, Germany (0x11a5)
|
2020-10-11 09:01:10 +00:00
|
|
|
type: Unknown (0x66)
|
|
|
|
ver: 0x23
|
|
|
|
driver: izar
|
2019-11-26 13:24:17 +00:00
|
|
|
Received telegram from: 64646464
|
2020-09-04 09:31:49 +00:00
|
|
|
manufacturer: (DME) DIEHL Metering, Germany (0x11a5)
|
2020-10-11 09:01:10 +00:00
|
|
|
type: Water meter (0x07)
|
|
|
|
ver: 0x70
|
|
|
|
driver: hydrus
|
2020-09-27 09:01:36 +00:00
|
|
|
Received telegram from: 65656565
|
|
|
|
manufacturer: (DME) DIEHL Metering, Germany (0x11a5)
|
2020-10-11 09:01:10 +00:00
|
|
|
type: Warm Water (30°C-90°C) meter (0x06)
|
|
|
|
ver: 0x70
|
|
|
|
driver: hydrus
|
2019-12-07 13:46:28 +00:00
|
|
|
Received telegram from: 86868686
|
2020-09-04 09:31:49 +00:00
|
|
|
manufacturer: (BMT) BMETERS, Italy (0x9b4)
|
2020-10-11 09:01:10 +00:00
|
|
|
type: Water meter (0x07)
|
|
|
|
ver: 0x13
|
|
|
|
driver: hydrodigit
|
2020-01-27 15:53:18 +00:00
|
|
|
Received telegram from: 72727272
|
2020-09-04 09:31:49 +00:00
|
|
|
manufacturer: (AXI) UAB Axis Industries, Lithuania (0x709)
|
2020-10-11 09:01:10 +00:00
|
|
|
type: Water meter (0x07)
|
|
|
|
ver: 0x10
|
|
|
|
driver: q400
|
2020-02-06 12:14:46 +00:00
|
|
|
Received telegram from: 22992299
|
2020-09-04 09:31:49 +00:00
|
|
|
manufacturer: (EBZ) eBZ, Germany (0x145a)
|
2020-10-11 09:01:10 +00:00
|
|
|
type: Radio converter (meter side) (0x37)
|
|
|
|
ver: 0x02
|
|
|
|
driver: ebzwmbe
|
2020-02-06 14:41:48 +00:00
|
|
|
Received telegram from: 77997799
|
2020-09-04 09:31:49 +00:00
|
|
|
manufacturer: (ESY) EasyMeter (0x1679)
|
2020-10-11 09:01:10 +00:00
|
|
|
type: Radio converter (meter side) (0x37)
|
|
|
|
ver: 0x30
|
|
|
|
driver: esyswm
|
2020-02-06 14:41:48 +00:00
|
|
|
Received telegram from: 77997799
|
2020-09-04 09:31:49 +00:00
|
|
|
manufacturer: (ESY) EasyMeter (0x1679)
|
2020-10-11 09:01:10 +00:00
|
|
|
type: Radio converter (meter side) (0x37)
|
|
|
|
ver: 0x30
|
|
|
|
driver: esyswm
|
2020-02-06 17:20:47 +00:00
|
|
|
Received telegram from: 55995599
|
2020-09-04 09:31:49 +00:00
|
|
|
manufacturer: (EMH) EMH metering formerly EMH Elektrizitatszahler (0x15a8)
|
2020-10-11 09:01:10 +00:00
|
|
|
type: Electricity meter (0x02)
|
|
|
|
ver: 0x02
|
|
|
|
driver: ehzp
|
2020-02-23 17:41:21 +00:00
|
|
|
Received telegram from: 004444dd
|
2020-09-04 09:31:49 +00:00
|
|
|
manufacturer: (APT) Unknown (0x8614)
|
2020-10-11 09:01:10 +00:00
|
|
|
type: Gas meter (0x03)
|
|
|
|
ver: 0x03
|
|
|
|
driver: apator08
|
2020-05-30 07:51:25 +00:00
|
|
|
Received telegram from: 74737271
|
2020-09-04 09:31:49 +00:00
|
|
|
manufacturer: (BMT) BMETERS, Italy (0x9b4)
|
2020-10-11 09:01:10 +00:00
|
|
|
type: Water meter (0x07)
|
|
|
|
ver: 0x05
|
|
|
|
driver: rfmtx1
|
2020-07-30 10:19:54 +00:00
|
|
|
Received telegram from: 20096221
|
2020-09-04 09:31:49 +00:00
|
|
|
manufacturer: (DWZ) Lorenz, Germany (0x12fa)
|
2020-10-11 09:01:10 +00:00
|
|
|
type: Warm Water (30°C-90°C) meter (0x06)
|
|
|
|
ver: 0x02
|
|
|
|
driver: waterstarm
|
2020-09-02 11:17:52 +00:00
|
|
|
Received telegram from: 78563412
|
2020-09-04 09:31:49 +00:00
|
|
|
manufacturer: (AMT) INTEGRA METERING (0x5b4)
|
2020-10-11 09:01:10 +00:00
|
|
|
type: Water meter (0x07)
|
|
|
|
ver: 0xf1
|
|
|
|
driver: topaseskr
|
2020-11-03 17:15:51 +00:00
|
|
|
Received telegram from: 95969798
|
|
|
|
manufacturer: (APA) Apator, Poland (0x601)
|
|
|
|
type: Cold water meter (0x16)
|
|
|
|
ver: 0x01
|
|
|
|
driver: ultrimis
|
2019-02-28 16:30:29 +00:00
|
|
|
EOF
|
2019-04-27 11:31:13 +00:00
|
|
|
|
2019-02-28 16:30:29 +00:00
|
|
|
RES=$($PROG --logfile=$LOGFILE --t1 simulations/simulation_t1.txt 2>&1)
|
|
|
|
|
|
|
|
if [ ! "$RES" = "" ]
|
|
|
|
then
|
2019-11-03 21:00:18 +00:00
|
|
|
echo ERROR: $TESTNAME
|
2019-02-28 16:30:29 +00:00
|
|
|
echo Expected no output on stdout and stderr
|
|
|
|
echo but got------------------
|
|
|
|
echo $RES
|
|
|
|
echo ---------------------
|
2019-11-03 21:00:18 +00:00
|
|
|
exit 1
|
2019-02-28 16:30:29 +00:00
|
|
|
fi
|
|
|
|
|
2020-02-23 17:41:21 +00:00
|
|
|
RES=$(diff $LOGFILE $LOGFILE_EXPECTED)
|
2020-01-27 15:53:18 +00:00
|
|
|
|
2020-02-23 17:41:21 +00:00
|
|
|
if [ ! -z "$RES" ]
|
2019-02-28 16:30:29 +00:00
|
|
|
then
|
2019-11-03 21:00:18 +00:00
|
|
|
echo ERROR: $TESTNAME
|
2020-02-23 17:41:21 +00:00
|
|
|
echo -----------------
|
|
|
|
diff $LOGFILE $LOGFILE_EXPECTED
|
2019-02-28 16:30:29 +00:00
|
|
|
echo -----------------
|
|
|
|
exit 1
|
|
|
|
else
|
2019-11-03 21:00:18 +00:00
|
|
|
echo OK: $TESTNAME
|
2019-02-28 16:30:29 +00:00
|
|
|
fi
|
|
|
|
|
2019-11-03 21:00:18 +00:00
|
|
|
TESTNAME="Test listen and print any meter heard on stdout"
|
|
|
|
TESTRESULT="ERROR"
|
|
|
|
|
2020-09-13 14:55:22 +00:00
|
|
|
$PROG --t1 simulations/simulation_t1.txt 2> $LOGFILE
|
2020-02-23 17:41:21 +00:00
|
|
|
|
|
|
|
RES=$(diff $LOGFILE $LOGFILE_EXPECTED)
|
2019-02-28 16:30:29 +00:00
|
|
|
|
2020-02-23 17:41:21 +00:00
|
|
|
if [ ! -z "$RES" ]
|
2019-02-28 16:30:29 +00:00
|
|
|
then
|
2019-11-03 21:00:18 +00:00
|
|
|
echo ERROR: $TESTNAME
|
2020-02-23 17:41:21 +00:00
|
|
|
echo -----------------
|
|
|
|
diff $LOGFILE $LOGFILE_EXPECTED
|
2019-02-28 16:30:29 +00:00
|
|
|
echo -----------------
|
|
|
|
exit 1
|
|
|
|
else
|
2019-11-03 21:00:18 +00:00
|
|
|
echo OK: $TESTNAME
|
2019-02-28 16:30:29 +00:00
|
|
|
fi
|