kopia lustrzana https://github.com/weetmuts/wmbusmeters
236 wiersze
7.7 KiB
C++
236 wiersze
7.7 KiB
C++
|
/*
|
||
|
Copyright (C) 2021 Olli Salonen
|
||
|
|
||
|
This program is free software: you can redistribute it and/or modify
|
||
|
it under the terms of the GNU General Public License as published by
|
||
|
the Free Software Foundation, either version 3 of the License, or
|
||
|
(at your option) any later version.
|
||
|
|
||
|
This program is distributed in the hope that it will be useful,
|
||
|
but WITHOUT ANY WARRANTY; without even the implied warranty of
|
||
|
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
||
|
GNU General Public License for more details.
|
||
|
|
||
|
You should have received a copy of the GNU General Public License
|
||
|
along with this program. If not, see <http://www.gnu.org/licenses/>.
|
||
|
*/
|
||
|
|
||
|
#include"dvparser.h"
|
||
|
#include"meters.h"
|
||
|
#include"meters_common_implementation.h"
|
||
|
#include"wmbus.h"
|
||
|
#include"wmbus_utils.h"
|
||
|
|
||
|
struct MeterMinomess : public virtual WaterMeter, public virtual MeterCommonImplementation {
|
||
|
MeterMinomess(MeterInfo &mi);
|
||
|
|
||
|
// Total water counted through the meter
|
||
|
double totalWaterConsumption(Unit u);
|
||
|
bool hasTotalWaterConsumption();
|
||
|
|
||
|
double targetWaterConsumption(Unit u);
|
||
|
bool hasTargetWaterConsumption();
|
||
|
|
||
|
private:
|
||
|
|
||
|
string status();
|
||
|
uint16_t info_codes_ {};
|
||
|
void processContent(Telegram *t);
|
||
|
|
||
|
double total_water_consumption_m3_ {};
|
||
|
string meter_date_ {};
|
||
|
double target_water_consumption_m3_ {};
|
||
|
string target_water_consumption_date_ {};
|
||
|
bool has_target_water_consumption_ {};
|
||
|
|
||
|
};
|
||
|
|
||
|
MeterMinomess::MeterMinomess(MeterInfo &mi) :
|
||
|
MeterCommonImplementation(mi, MeterDriver::MINOMESS)
|
||
|
{
|
||
|
setExpectedELLSecurityMode(ELLSecurityMode::AES_CTR);
|
||
|
|
||
|
addLinkMode(LinkMode::C1);
|
||
|
|
||
|
addPrint("total", Quantity::Volume,
|
||
|
[&](Unit u){ return totalWaterConsumption(u); },
|
||
|
"The total water consumption recorded by this meter.",
|
||
|
true, true);
|
||
|
|
||
|
addPrint("meter_date", Quantity::Text,
|
||
|
[&](){ return meter_date_; },
|
||
|
"Date when measurement was recorded.",
|
||
|
false, true);
|
||
|
|
||
|
addPrint("target", Quantity::Volume,
|
||
|
[&](Unit u){ return targetWaterConsumption(u); },
|
||
|
"The total water consumption recorded at the beginning of this month.",
|
||
|
true, true);
|
||
|
|
||
|
addPrint("target_date", Quantity::Text,
|
||
|
[&](){ return target_water_consumption_date_; },
|
||
|
"Date when target water consumption was recorded.",
|
||
|
false, true);
|
||
|
|
||
|
addPrint("status", Quantity::Text,
|
||
|
[&](){ return status(); },
|
||
|
"Status of meter.",
|
||
|
true, true);
|
||
|
|
||
|
}
|
||
|
|
||
|
shared_ptr<WaterMeter> createMinomess(MeterInfo &mi)
|
||
|
{
|
||
|
return shared_ptr<WaterMeter>(new MeterMinomess(mi));
|
||
|
}
|
||
|
|
||
|
double MeterMinomess::totalWaterConsumption(Unit u)
|
||
|
{
|
||
|
assertQuantity(u, Quantity::Volume);
|
||
|
return convert(total_water_consumption_m3_, Unit::M3, u);
|
||
|
}
|
||
|
|
||
|
bool MeterMinomess::hasTotalWaterConsumption()
|
||
|
{
|
||
|
return true;
|
||
|
}
|
||
|
|
||
|
double MeterMinomess::targetWaterConsumption(Unit u)
|
||
|
{
|
||
|
assertQuantity(u, Quantity::Volume);
|
||
|
return convert(target_water_consumption_m3_, Unit::M3, u);
|
||
|
}
|
||
|
|
||
|
bool MeterMinomess::hasTargetWaterConsumption()
|
||
|
{
|
||
|
return has_target_water_consumption_;
|
||
|
}
|
||
|
|
||
|
void MeterMinomess::processContent(Telegram *t)
|
||
|
{
|
||
|
// 00: 66 length (102 bytes)
|
||
|
// 01: 44 dll-c (from meter SND_NR)
|
||
|
// 02: 496a dll-mfct (ZRI)
|
||
|
// 04: 10640355 dll-id (55036410)
|
||
|
// 08: 14 dll-version
|
||
|
// 09: 37 dll-type (Radio converter (meter side))
|
||
|
// 0a: 72 tpl-ci-field (EN 13757-3 Application Layer (long tplh))
|
||
|
// 0b: 51345015 tpl-id (15503451)
|
||
|
// 0f: 496a tpl-mfct (ZRI)
|
||
|
// 11: 00 tpl-version
|
||
|
// 12: 07 tpl-type (Water meter)
|
||
|
// 13: 76 tpl-acc-field
|
||
|
// 14: 00 tpl-sts-field (OK)
|
||
|
// 15: 5005 tpl-cfg 0550 (AES_CBC_IV nb=5 cntn=0 ra=0 hc=0 )
|
||
|
// 17: 2f2f decrypt check bytes
|
||
|
|
||
|
// 19: 0C dif (8 digit BCD Instantaneous value)
|
||
|
// 1a: 13 vif (Volume l)
|
||
|
// 1b: * 55140000 total consumption (1.455000 m3)
|
||
|
// 1f: 02 dif (16 Bit Integer/Binary Instantaneous value)
|
||
|
// 20: 6C vif (Date type G)
|
||
|
// 21: * A92B meter date (2021-11-09)
|
||
|
// 23: 82 dif (16 Bit Integer/Binary Instantaneous value)
|
||
|
// 24: 04 dife (subunit=0 tariff=0 storagenr=8)
|
||
|
// 25: 6C vif (Date type G)
|
||
|
// 26: * A12B target consumption reading date (2021-11-01)
|
||
|
// 28: 8C dif (8 digit BCD Instantaneous value)
|
||
|
// 29: 04 dife (subunit=0 tariff=0 storagenr=8)
|
||
|
// 2a: 13 vif (Volume l)
|
||
|
// 2b: * 71000000 target consumption (0.071000 m3)
|
||
|
//
|
||
|
// 2f: 8D dif (variable length Instantaneous value)
|
||
|
// 30: 04 dife (subunit=0 tariff=0 storagenr=8)
|
||
|
// 31: 93 vif (Volume l)
|
||
|
// 32: 13 vife (Reverse compact profile without register)
|
||
|
// 33: 2C varlen=44
|
||
|
// This register has 24-bit integers for the consumption of the past months n-2 until n-15.
|
||
|
// If the meter is commissioned less than 15 months ago, you will see FFFFFF as the value.
|
||
|
// n-2 n-3 n-4 n-5 n-6 n-7 n-8 n-9 n-10 n-11 n-12 n-13 n-14 n-15
|
||
|
// 34: FBFE 000000 FFFFFF FFFFFF FFFFFF FFFFFF FFFFFF FFFFFF FFFFFF FFFFFF FFFFFF FFFFFF FFFFFF FFFFFF FFFFFF
|
||
|
//
|
||
|
// 60: 02 dif (16 Bit Integer/Binary Instantaneous value)
|
||
|
// 61: FD vif (Second extension FD of VIF-codes)
|
||
|
// 62: 17 vife (Error flags (binary))
|
||
|
// 63: * 0000 info codes (OK)
|
||
|
|
||
|
int offset;
|
||
|
string key;
|
||
|
|
||
|
if (findKey(MeasurementType::Instantaneous, ValueInformation::Volume, 0, 0, &key, &t->values)) {
|
||
|
extractDVdouble(&t->values, key, &offset, &total_water_consumption_m3_);
|
||
|
t->addMoreExplanation(offset, " total consumption (%f m3)", total_water_consumption_m3_);
|
||
|
}
|
||
|
|
||
|
if (findKey(MeasurementType::Instantaneous, ValueInformation::Date, 0, 0, &key, &t->values)) {
|
||
|
struct tm date;
|
||
|
extractDVdate(&t->values, key, &offset, &date);
|
||
|
meter_date_ = strdate(&date);
|
||
|
t->addMoreExplanation(offset, " meter date (%s)", meter_date_.c_str());
|
||
|
}
|
||
|
|
||
|
if (findKey(MeasurementType::Instantaneous, ValueInformation::Volume, 8, 0, &key, &t->values)) {
|
||
|
uint32_t i;
|
||
|
extractDVdouble(&t->values, key, &offset, &target_water_consumption_m3_);
|
||
|
extractDVuint32(&t->values, key, &offset, &i);
|
||
|
/* if the meter is recently commissioned, the target water consumption value is bogus */
|
||
|
if (i != 0xffffffff) {
|
||
|
has_target_water_consumption_ = true;
|
||
|
} else {
|
||
|
target_water_consumption_m3_ = 0;
|
||
|
}
|
||
|
t->addMoreExplanation(offset, " target consumption (%f m3)", target_water_consumption_m3_);
|
||
|
}
|
||
|
|
||
|
if (findKey(MeasurementType::Instantaneous, ValueInformation::Date, 8, 0, &key, &t->values)) {
|
||
|
struct tm date;
|
||
|
extractDVdate(&t->values, key, &offset, &date);
|
||
|
target_water_consumption_date_ = strdate(&date);
|
||
|
t->addMoreExplanation(offset, " target consumption reading date (%s)", target_water_consumption_date_.c_str());
|
||
|
}
|
||
|
|
||
|
if (extractDVuint16(&t->values, "02FD17", &offset, &info_codes_)) {
|
||
|
t->addMoreExplanation(offset, " info codes (%s)", status().c_str());
|
||
|
}
|
||
|
|
||
|
}
|
||
|
|
||
|
string MeterMinomess::status()
|
||
|
{
|
||
|
/*
|
||
|
To-Do: Implement status handling
|
||
|
According to data sheet, there are two status/info bytes, byte A and byte B.
|
||
|
|
||
|
Byte A:
|
||
|
bit 7 removal active in the past
|
||
|
bit 6 tamper active in the past
|
||
|
bit 5 leak active in the past
|
||
|
bit 4 temporary error (in connection with smart functions)
|
||
|
bit 3 permanent error (meter value might be lost)
|
||
|
bit 2 battery EOL (measured)
|
||
|
bit 1 abnormal error
|
||
|
bit 0 unused
|
||
|
|
||
|
Byte B:
|
||
|
bit 7 burst
|
||
|
bit 6 removal
|
||
|
bit 5 leak
|
||
|
bit 4 backflow in the past
|
||
|
bit 3 backflow
|
||
|
bit 2 meter blocked in the past
|
||
|
bit 1 meter undersized
|
||
|
bit 0 meter oversized
|
||
|
*/
|
||
|
|
||
|
string s;
|
||
|
|
||
|
if (info_codes_ == 0) return "OK";
|
||
|
|
||
|
s = tostrprintf("%x", info_codes_);
|
||
|
if (s.length() > 0) {
|
||
|
s.pop_back(); // Remove final space
|
||
|
return s;
|
||
|
}
|
||
|
return s;
|
||
|
}
|