Notes:
The VK3CPU RF Transformer Calculator was developed to help users predict the RF characteristics of a ferrite toroid wound as a transformer.
It uses the manufacturer's (Fair-Rite) published data including the toroid's dimensions and complex permeability characteristics
- to predict the component's characteristics.
+ to predict the transformer's characteristics.
The calculator has 3 separate display areas. At the top is the chart display for showing frequency-dependent characteristics. Next is the
schematic display, where a scaled image of the toroid and windings is presented to help with intuitive design. Next is the control panel
- section, where the user can select the application type, toroid material, toroid size, wire size, number of windings and excitation voltage.
+ section, where the user can select the wire size, toroid material, toroid size, number of primary and secondary windings, input power and load impedance.
Inputs via the select widgets:
- - Application : Selects the intended use of the toroid, either Inductor or Suppressor is currently supported. This limits the material selection as appropriate.
- Size : Selects the size of the toroid. FT240 is 2.4" in diameter. FT80 is 0.8", etc...
- - Material : Manufacturers material mix code. Inductor mode shows initial permeability [μi] in square brackets. (Pick lower μi for higher frequency applications.)
- Suppressor mode displays effective suppression frequency range in square brackets.
+ - Material : Manufacturers material mix code. Select this first. Initial permeability [μi] is displayed in square brackets. (Pick lower μi for higher frequency applications.)
Inputs via the slider widgets:
- AWG : Select the wire gauge. Sliding L-R changes AWG from 40-0. (Defaults to 20 AWG)
- - N : Winding density at the toroid inner-diameter. Controls how many single-layer turns can be achieved around the core.
- Maximum (100%, slider to hard-right) is reached when the turns are adjacent at the toroid's inner radius. (Defaults to 15%)
- - Vrms : The RMS voltage applied to the inductor (Volts). Determines the flux-density (B) and field-intensity (H) within the ferrite toroid. (Defaults to 10Vrms)
- - f : Shifts the frequency of interest of the chart display from left-to-right. Left towards kHz, right towards GHz.
+ - Np : Number of turns for the primary Winding. (Defaults to 20 turns.)
+ - Ns : Number of turns for the secondary Winding. (Defaults to 20 turns.)
+ - P : The input power in watts. (Defaults to 100 W)
+ - Zl : Load impedance in ohms. (Defaults to 50 ohms.)
Note: Manufacturers recommend keeping the number of turns (N) to a minimum.
Chart display: