    <h1>Scanners not supported by SANE</h1>
 | 
						|
    <h2>Manufacturer and model</h2>
 | 
						|
    <p>
 | 
						|
      Microtek ScanMaker 4850 II
 | 
						|
    </p>
 | 
						|
    <h2>Bus type</h2>
 | 
						|
    <p>
 | 
						|
      USB
 | 
						|
    </p>
 | 
						|
    <h2>Vendor ID</h2>
 | 
						|
    <p>
 | 
						|
      0x05da
 | 
						|
    </p>
 | 
						|
    <h2>Product ID</h2>
 | 
						|
    <p>
 | 
						|
      0x3008
 | 
						|
    </p>
 | 
						|
    <h2>Chipset</h2>
 | 
						|
    <p>
 | 
						|
    </p>
 | 
						|
    <h2>Comments</h2>
 | 
						|
    <p>
 | 
						|
      Same ids as Tevion MD 40420 and Tevion MD 42666.
 | 
						|
    </p>
 | 
						|
    <h2>Output of /proc/bus/usb/devices or sane-find-scanner -v -v or lsusb -vv</h2>
 | 
						|
    <pre>
 | 
						|
T:  Bus=04 Lev=01 Prnt=01 Port=02 Cnt=01 Dev#=  3 Spd=480 MxCh= 0
 | 
						|
D:  Ver= 2.00 Cls=00(>ifc ) Sub=00 Prot=00 MxPS=64 #Cfgs=  1
 | 
						|
P:  Vendor=05da ProdID=3008 Rev= 1.00
 | 
						|
S:  Manufacturer=Prolific Technology Inc.
 | 
						|
S:  Product=USB Scanner
 | 
						|
C:* #Ifs= 1 Cfg#= 1 Atr=c0 MxPwr=100mA
 | 
						|
I:  If#= 0 Alt= 0 #EPs= 3 Cls=ff(vend.) Sub=ff Prot=ff Driver=(none)
 | 
						|
E:  Ad=01(O) Atr=02(Bulk) MxPS= 512 Ivl=0ms
 | 
						|
E:  Ad=82(I) Atr=02(Bulk) MxPS= 512 Ivl=0ms
 | 
						|
E:  Ad=83(I) Atr=03(Int.) MxPS=   1 Ivl=500us
 | 
						|
 | 
						|
This is sane-find-scanner from sane-backends 1.0.17
 | 
						|
<device descriptor of 0x05da/0x3008 at 004:003>
 | 
						|
bLength               18
 | 
						|
bDescriptorType       1
 | 
						|
bcdUSB                2.00
 | 
						|
bDeviceClass          0
 | 
						|
bDeviceSubClass       0
 | 
						|
bDeviceProtocol       0
 | 
						|
bMaxPacketSize0       64
 | 
						|
idVendor              0x05DA
 | 
						|
idProduct             0x3008
 | 
						|
bcdDevice             1.00
 | 
						|
iManufacturer         1 ((null))
 | 
						|
iProduct              2 ((null))
 | 
						|
iSerialNumber         0 ()
 | 
						|
bNumConfigurations    1
 | 
						|
 <configuration 0>
 | 
						|
 bLength              9
 | 
						|
 bDescriptorType      2
 | 
						|
 wTotalLength         39
 | 
						|
 bNumInterfaces       1
 | 
						|
 bConfigurationValue  1
 | 
						|
 iConfiguration       0 ()
 | 
						|
 bmAttributes         192 (Self-powered)
 | 
						|
 MaxPower             100 mA
 | 
						|
  <interface 0>
 | 
						|
   <altsetting 0>
 | 
						|
   bLength            9
 | 
						|
   bDescriptorType    4
 | 
						|
   bInterfaceNumber   0
 | 
						|
   bAlternateSetting  0
 | 
						|
   bNumEndpoints      3
 | 
						|
   bInterfaceClass    255
 | 
						|
   bInterfaceSubClass 255
 | 
						|
   bInterfaceProtocol 255
 | 
						|
   iInterface         0 ()
 | 
						|
    <endpoint 0>
 | 
						|
    bLength           7
 | 
						|
    bDescriptorType   5
 | 
						|
    bEndpointAddress  0x01 (out 0x01)
 | 
						|
    bmAttributes      2 (bulk)
 | 
						|
    wMaxPacketSize    512
 | 
						|
    bInterval         0 ms
 | 
						|
    bRefresh          0
 | 
						|
    bSynchAddress     0
 | 
						|
    <endpoint 1>
 | 
						|
    bLength           7
 | 
						|
    bDescriptorType   5
 | 
						|
    bEndpointAddress  0x82 (in 0x02)
 | 
						|
    bmAttributes      2 (bulk)
 | 
						|
    wMaxPacketSize    512
 | 
						|
    bInterval         0 ms
 | 
						|
    bRefresh          0
 | 
						|
    bSynchAddress     0
 | 
						|
    <endpoint 2>
 | 
						|
    bLength           7
 | 
						|
    bDescriptorType   5
 | 
						|
    bEndpointAddress  0x83 (in 0x03)
 | 
						|
    bmAttributes      3 (interrupt)
 | 
						|
    wMaxPacketSize    1
 | 
						|
    bInterval         3 ms
 | 
						|
    bRefresh          0
 | 
						|
    bSynchAddress     0
 | 
						|
 | 
						|
<trying to find out which USB chip is used>
 | 
						|
    checking for GT-6801 ...
 | 
						|
    this is not a GT-6801 (bDeviceClass = 0)
 | 
						|
    checking for GT-6816 ...
 | 
						|
    this is not a GT-6816 (bcdUSB = 0x200)
 | 
						|
    checking for GT-8911 ...
 | 
						|
    this is not a GT-8911 (check 2, bcdUSB = 0x200)
 | 
						|
    checking for MA-1017 ...
 | 
						|
    this is not a MA-1017 (bDeviceClass = 0, bInterfaceClass = 255)
 | 
						|
    checking for MA-1015 ...
 | 
						|
    this is not a MA-1015 (bDeviceClass = 0)
 | 
						|
    checking for MA-1509 ...
 | 
						|
    this is not a MA-1509 (bDeviceClass = 0)
 | 
						|
    checking for LM983[1,2,3] ...
 | 
						|
    this is not a LM983x (bcdUSB = 0x200)
 | 
						|
    checking for GL646 ...
 | 
						|
    this is not a GL646 (bDeviceClass = 0, bInterfaceClass = 255)
 | 
						|
    checking for GL646_HP ...
 | 
						|
    this is not a GL646_HP (bDeviceClass = 0, bInterfaceClass = 255)
 | 
						|
    checking for GL660+GL646 ...
 | 
						|
    this is not a GL660+GL646 (bDeviceClass = 0, bInterfaceClass = 255)
 | 
						|
    checking for GL841 ...
 | 
						|
    this is not a GL841 (bDeviceClass = 0, bInterfaceClass = 255)
 | 
						|
    checking for ICM532B ...
 | 
						|
    this is not a ICM532B (check 1, bDeviceClass = 0, bInterfaceClass = 255)
 | 
						|
    checking for PV8630/LM9830 ...
 | 
						|
    this is not a PV8630/LM9830 (bcdUSB = 0x200)
 | 
						|
    checking for M011 ...
 | 
						|
    this is not a M011 (bDeviceClass = 0)
 | 
						|
    checking for RTS8822L-01H ...
 | 
						|
    this is not a RTS8822L-01H (bEndpointAddress = 0x1, bmAttributes = 0x2, wMaxPacketSize = 0x200, bInterval = 0x0)
 | 
						|
    checking for rts8858c ...
 | 
						|
    this is not a rts8858c (bcdUSB = 0x200)
 | 
						|
    checking for SQ113 ...
 | 
						|
  Couldn't set configuration: could not set config 1: Operation not permitted
 | 
						|
<This USB chip looks like a SQ113?>
 | 
						|
 | 
						|
found USB scanner (vendor=0x05da, product=0x3008, chip=SQ113?) at libusb:004:003
 | 
						|
    </pre>
 | 
						|
    
 | 
						|
    <h1>Want to add or correct information?</h1>
 | 
						|
    <p>
 | 
						|
      If anything is wrong or missing on this page please <a href="../bugs.html">file a bug report</a>
 | 
						|
      or use the <a href="http://www.meier-geinitz.de:80/tinc?key=rDoQ7lrj&formname=adddev" target="_top">the
 | 
						|
      form for adding an unsupported device</a>.
 | 
						|
    </p>
 | 
						|
    <p>
 | 
						|
      If you own an unsupported scanner, please send as much information as
 | 
						|
      possible. Especially the output of <em>sane-find-scanner -v -v</em>
 | 
						|
      and/or <em>cat /proc/scsi/scsi</em> (for SCSI scanners) or <em>cat
 | 
						|
      /proc/bus/usb/devices</em> (for USB scanners) can help. If you dare to
 | 
						|
      open the scanner, have a look at the text that's printed on the
 | 
						|
      chips. That may help to identify the chipset.  If you know that the
 | 
						|
      scanner is similar to another one (e.g. supported by the same Windows
 | 
						|
      driver), please also mention this fact.
 | 
						|
    </p>
 | 
						|
 | 
						|
    <h1><a href="../manufacturers.html">Information for Manufacturers</a></h1>
 | 
						|
    <p>
 | 
						|
      Are you a manufacturer or vendor of scanners and one of your scanners is
 | 
						|
      not supported by SANE yet? In this case please have a look at our <a
 | 
						|
      href="../manufacturers.html">information for manufacturers</a>.
 | 
						|
    </p>
 | 
						|
    
 | 
						|
    <hr>
 | 
						|
    
 | 
						|
    <p>
 | 
						|
      <a href="../">SANE homepage</a><br>
 | 
						|
      <a href="../imprint.html">Contact</a>
 | 
						|
    </p>
 | 
						|
  </body>
 | 
						|
  
 | 
						|
</html>
 |