<H2>NAME</H2><PRE>
|
|
sane-st400 - SANE backend for Siemens ST/Highscan flatbed scanners
|
|
|
|
|
|
</PRE>
|
|
<H2>DESCRIPTION</H2><PRE>
|
|
The <B>sane-st400</B> library implements a SANE (Scanner Access Now Easy)
|
|
backend that provides access to Siemens ST400 flatbed scanners and com-
|
|
patibles. At present, the following scanners are supported by this
|
|
backend:
|
|
|
|
Siemens ST400 (6 bit gray scale)
|
|
Siemens ST800 (6 bit gray scale)
|
|
|
|
The driver supports line art and gray scans up to 8bpp.
|
|
|
|
The Siemens ST/Highscan series includes several more models, e.g. the
|
|
ST300 and ST600. If you own one of these scanners, or a scanner other
|
|
than the ones listed above that works with this backend, please let us
|
|
know by sending the scanner's model name, SCSI ID, and firmware revi-
|
|
sion to <I>sane-devel@lists.alioth.debian.org</I>. Have a look at
|
|
http://www.sane-project.org/mailing-lists.html concerning subscription
|
|
to sane-devel.
|
|
|
|
|
|
</PRE>
|
|
<H2>DEVICE NAMES</H2><PRE>
|
|
This backend expects device names of the form:
|
|
|
|
<I>special</I>
|
|
|
|
Where <I>special</I> is either the path-name for the special device that cor-
|
|
responds to a SCSI scanner. For SCSI scanners, the special device name
|
|
must be a generic SCSI device or a symlink to such a device. Under
|
|
Linux, such a device name could be <I>/dev/sga</I> or <I>/dev/sge</I>, for example.
|
|
See <B><A HREF="sane-scsi.5.html">sane-scsi(5)</A></B> for details.
|
|
|
|
|
|
</PRE>
|
|
<H2>CONFIGURATION</H2><PRE>
|
|
The contents of the <I>st400.conf</I> file is a list of device names that cor-
|
|
respond to Siemens scanners. Empty lines and lines starting with a
|
|
hash mark (#) are ignored. A sample configuration file is shown below:
|
|
|
|
/dev/scanner
|
|
# this is a comment
|
|
/dev/sge
|
|
|
|
The default configuration file that is distributed with SANE looks like
|
|
this:
|
|
|
|
scsi SIEMENS "ST 400" Scanner * * 3 0
|
|
|
|
In this configuration, the driver can only access the ST400 model at
|
|
SCSI ID 3 LUN 0 (see section "BUGS" below for the reason). To use the
|
|
driver with other scanner models, add an appropriate line to the con-
|
|
figuration file. For example, to use it with an ST800 at SCSI ID 3 LUN
|
|
0, add the line:
|
|
|
|
scsi SIEMENS "ST 800" Scanner * * 3 0
|
|
|
|
|
|
</PRE>
|
|
<H2>FILES</H2><PRE>
|
|
<I>/usr/local/etc/sane.d/st400.conf</I>
|
|
The backend configuration file (see also description of
|
|
<B>SANE_CONFIG_DIR</B> below).
|
|
|
|
<I>/usr/local/lib/sane/libsane-st400.a</I>
|
|
The static library implementing this backend.
|
|
|
|
<I>/usr/local/lib/sane/libsane-st400.so</I>
|
|
The shared library implementing this backend (present on systems
|
|
that support dynamic loading).
|
|
|
|
|
|
</PRE>
|
|
<H2>ENVIRONMENT</H2><PRE>
|
|
<B>SANE_CONFIG_DIR</B>
|
|
This environment variable specifies the list of directories that
|
|
may contain the configuration file. Under UNIX, the directories
|
|
are separated by a colon (`:'), under OS/2, they are separated
|
|
by a semi-colon (`;'). If this variable is not set, the config-
|
|
uration file is searched in two default directories: first, the
|
|
current working directory (".") and then in /etc/sane.d. If the
|
|
value of the environment variable ends with the directory sepa-
|
|
rator character, then the default directories are searched after
|
|
the explicitly specified directories. For example, setting
|
|
<B>SANE_CONFIG_DIR</B> to "/tmp/config:" would result in directories
|
|
"tmp/config", ".", and "/etc/sane.d" being searched (in this
|
|
order).
|
|
|
|
<B>SANE_DEBUG_ST400</B>
|
|
If the library was compiled with debug support enabled, this
|
|
environment variable controls the debug level for this backend.
|
|
E.g., a value of 128 requests all debug output to be printed.
|
|
Smaller levels reduce verbosity.
|
|
|
|
|
|
</PRE>
|
|
<H2>MISSING FUNCTIONALITY</H2><PRE>
|
|
Everything but the most basic stuff.
|
|
|
|
|
|
</PRE>
|
|
<H2>BUGS</H2><PRE>
|
|
Currently, the backend does not check if the attached device really is
|
|
a ST400. It will happily accept everything that matches the configura-
|
|
tion entries. This makes it easy to test the backend with other scan-
|
|
ners: Just add an appropriate line to the configuration file. The con-
|
|
figuration file as distributed (see above) only works with the ST400.
|
|
Be careful: If there is no config file at all, the backend defaults to
|
|
/dev/scanner.
|
|
|
|
The ST400 answers on all eight SCSI LUNs. Normally this is not a prob-
|
|
lem, as LUN support is usually disabled in SCSI drivers, but if you are
|
|
seeing multiple instances of the scanner in a device list, either dis-
|
|
able LUNs in your SCSI setup or change the entry in the configuration
|
|
file to match LUN 0 only.
|
|
|
|
|
|
</PRE>
|
|
<H2>DEBUG</H2><PRE>
|
|
If you encounter a bug please set the environment variable
|
|
SANE_DEBUG_ST400 to 128 and try to regenerate the problem. Then send me
|
|
a report with the log attached.
|
|
|
|
If you encounter a SCSI bus error or trimmed and/or displaced images
|
|
please also set the environment variable SANE_DEBUG_SANEI_SCSI to 128
|
|
before sending me the report.
|
|
|
|
|
|
</PRE>
|
|
<H2>SEE ALSO</H2><PRE>
|
|
<B><A HREF="sane.7.html">sane(7)</A></B>, <B><A HREF="sane-scsi.5.html">sane-scsi(5)</A></B>
|
|
http://www.informatik.uni-oldenburg.de/~ingo/sane/
|
|
|
|
|
|
</PRE>
|
|
<H2>AUTHOR</H2><PRE>
|
|
Ingo Wilken <Ingo.Wilken@informatik.uni-oldenburg.de>
|
|
|
|
sane-backends 1.0.12-cvs 08 Mar 1999 <B><A HREF="sane-st400.5.html">sane-st400(5)</A></B>
|
|
</PRE>
|
|
<HR>
|
|
<ADDRESS>
|
|
Man(1) output converted with
|
|
<a href="http://www.oac.uci.edu/indiv/ehood/man2html.html">man2html</a>
|
|
</ADDRESS>
|
|
</BODY>
|
|
</HTML>
|