kopia lustrzana https://gitlab.com/sane-project/website
285 wiersze
9.2 KiB
HTML
285 wiersze
9.2 KiB
HTML
<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN">
|
|
|
|
<html>
|
|
<head>
|
|
<title>Scanner information</title>
|
|
<meta http-equiv="Content-Type" content="text/html; charset=iso-8859-1">
|
|
<meta name="author" content="Henning Meier-Geinitz">
|
|
<meta name="keywords" content="sane, backend, driver, scanner, unsupported">
|
|
<link href="mailto:henning@meier-geinitz.de" rev="made">
|
|
<link rel="icon" href="/favicon.ico" type="image/x-icon">
|
|
<link rel="shortcut icon" href="/favicon.ico" type="image/x-icon">
|
|
</head>
|
|
|
|
|
|
<body>
|
|
<h1>Scanners not supported by SANE</h1>
|
|
<h2>Manufacturer and model</h2>
|
|
<p>
|
|
Hewlett-Packard Scanjet 4570c
|
|
</p>
|
|
<h2>Bus type</h2>
|
|
<p>
|
|
USB
|
|
</p>
|
|
<h2>Vendor ID</h2>
|
|
<p>
|
|
0x03f0
|
|
</p>
|
|
<h2>Product ID</h2>
|
|
<p>
|
|
0x1305
|
|
</p>
|
|
<h2>Chipset</h2>
|
|
<p>
|
|
Similar to a GL841. Not yet confirmed, however. sane-find-scanner seems to
|
|
be able to communicate with the chipset in GL841 mode but it doesn't get
|
|
the same value it writes to the register back when reading.
|
|
</p>
|
|
<pre>
|
|
These are the chips on the board:
|
|
|
|
U1
|
|
AH50
|
|
169F8
|
|
|
|
Pinout: 3 pins
|
|
|
|
U2,U3,U14
|
|
ATC
|
|
AP34063
|
|
0241A
|
|
|
|
DC/DC Converter
|
|
http://www.anachip.com/downloads/datasheets/power/sw_reg/AP34063.pdf
|
|
|
|
U4
|
|
WM8199CDS
|
|
28AC3TX
|
|
|
|
16-bit analogue front end/digitiser
|
|
http://www.wolfsonmicro.com/products/digital_imaging/WM8199/
|
|
|
|
U6
|
|
26-00188-00B
|
|
0240MF79K-01
|
|
|
|
Pinout: 4x52 = 208
|
|
|
|
U7
|
|
A3967SLB
|
|
A 0243
|
|
M243967APA
|
|
|
|
Step motor driver
|
|
http://www.allegromicro.com/sf/3967/
|
|
|
|
U8
|
|
Winbond
|
|
241WH
|
|
W981616BH-7
|
|
|
|
16Mbit SDRAM
|
|
http://www.winbond.com/e-winbondhtm/partner/PDFresult.asp?Pname=241
|
|
|
|
U9
|
|
Ver 026
|
|
CheckSum:
|
|
9D29
|
|
|
|
EPROM?
|
|
Pinout: 4x9
|
|
|
|
U10
|
|
26-00053-02A
|
|
0227MFASH-33
|
|
|
|
Pinout: 4x12
|
|
|
|
U12
|
|
24LC08B
|
|
SN0212
|
|
|
|
8K I2C Serial EE
|
|
http://www.microchip.com/download/lit/pline/memory/ic/21710a.pdf
|
|
</pre>
|
|
<h2>Comments</h2>
|
|
<p>
|
|
Some discussion about the protocol can be found in the <a
|
|
href="http://lists.alioth.debian.org/pipermail/sane-devel/2005-September/014618.html">sane-devel
|
|
mailinglist archive</a>.
|
|
</p>
|
|
<p>
|
|
Portrait scanner with TA, similar to <a
|
|
href="hp-scanjet-4500c.html">4500C</a>. Same as 5550C, but without
|
|
ADF. The manual says: 4500c and 5500c series.
|
|
</p>
|
|
<p>
|
|
For more information, see bug report <a href="https://alioth.debian.org/tracker/index.php?func=detail&aid=301110&group_id=30186&atid=410366">#301110</a>.
|
|
</p>
|
|
<p>
|
|
"According to manual similar to 4500c and 5500c series scanners. It comes
|
|
with a transparent materials adaptor (TMA). [...] The TMA is an external
|
|
device which can be unplugged. Windows XP refers to it as HP ScanJet
|
|
4570c/5500c Windows uses usbscn.sys hpgtbb.dll hpgwiand.dll hpsjvset.dll."
|
|
</p>
|
|
<h2>Output of /proc/bus/usb/devices or sane-find-scanner -v -v</h2>
|
|
<pre>
|
|
T: Bus=01 Lev=01 Prnt=01 Port=00 Cnt=01 Dev#= 2 Spd=12 MxCh= 0
|
|
D: Ver= 2.00 Cls=ff(vend.) Sub=ff Prot=ff MxPS=64 #Cfgs= 1
|
|
P: Vendor=03f0 ProdID=1305 Rev= 3.01
|
|
S: Manufacturer=Hewlett-Packard
|
|
S: Product=hp scanjet scanner
|
|
C:* #Ifs= 1 Cfg#= 1 Atr=c0 MxPwr= 10mA
|
|
I: If#= 0 Alt= 0 #EPs= 3 Cls=ff(vend.) Sub=ff Prot=ff Driver=(none)
|
|
E: Ad=81(I) Atr=02(Bulk) MxPS= 64 Ivl=0ms
|
|
E: Ad=02(O) Atr=02(Bulk) MxPS= 64 Ivl=0ms
|
|
E: Ad=83(I) Atr=03(Int.) MxPS= 1 Ivl=8ms
|
|
|
|
<device descriptor of 0x03f0/0x1305 at 001:002 (Hewlett-Packard hp
|
|
scanjet scanner)>
|
|
bLength 18
|
|
bDescriptorType 1
|
|
bcdUSB 2.00
|
|
bDeviceClass 255
|
|
bDeviceSubClass 255
|
|
bDeviceProtocol 255
|
|
bMaxPacketSize0 64
|
|
idVendor 0x03F0
|
|
idProduct 0x1305
|
|
bcdDevice 3.01
|
|
iManufacturer 1 (Hewlett-Packard)
|
|
iProduct 2 (hp scanjet scanner)
|
|
iSerialNumber 0 ()
|
|
bNumConfigurations 1
|
|
<configuration 0>
|
|
bLength 9
|
|
bDescriptorType 2
|
|
wTotalLength 39
|
|
bNumInterfaces 1
|
|
bConfigurationValue 1
|
|
iConfiguration 0 ()
|
|
bmAttributes 192 (Self-powered)
|
|
MaxPower 10 mA
|
|
<interface 0>
|
|
<altsetting 0>
|
|
bLength 9
|
|
bDescriptorType 4
|
|
bInterfaceNumber 0
|
|
bAlternateSetting 0
|
|
bNumEndpoints 3
|
|
bInterfaceClass 255
|
|
bInterfaceSubClass 255
|
|
bInterfaceProtocol 255
|
|
iInterface 0 ()
|
|
<endpoint 0>
|
|
bLength 7
|
|
bDescriptorType 5
|
|
bEndpointAddress 0x81 (in 0x01)
|
|
bmAttributes 2 (bulk)
|
|
wMaxPacketSize 512
|
|
bInterval 0 ms
|
|
bRefresh 0
|
|
bSynchAddress 0
|
|
<endpoint 1>
|
|
bLength 7
|
|
bDescriptorType 5
|
|
bEndpointAddress 0x02 (out 0x02)
|
|
bmAttributes 2 (bulk)
|
|
wMaxPacketSize 512
|
|
bInterval 0 ms
|
|
bRefresh 0
|
|
bSynchAddress 0
|
|
<endpoint 2>
|
|
bLength 7
|
|
bDescriptorType 5
|
|
bEndpointAddress 0x83 (in 0x03)
|
|
bmAttributes 3 (interrupt)
|
|
wMaxPacketSize 1
|
|
bInterval 8 ms
|
|
bRefresh 0
|
|
bSynchAddress 0
|
|
|
|
<trying to find out which USB chip is used>
|
|
checking for GT-6801 ...
|
|
this is not a GT-6801 (bcdUSB = 0x200)
|
|
checking for GT-6816 ...
|
|
this is not a GT-6816 (bDeviceClass = 255, bInterfaceClass = 255)
|
|
checking for MA-1017 ...
|
|
this is not a MA-1017 (bDeviceClass = 255, bInterfaceClass = 255)
|
|
checking for MA-1015 ...
|
|
this is not a MA-1015 (bcdUSB = 0x200)
|
|
checking for MA-1509 ...
|
|
this is not a MA-1509 (bcdUSB = 0x200)
|
|
checking for LM983[1,2,3] ...
|
|
this is not a LM983x (bcdUSB = 0x200)
|
|
checking for GL646 ...
|
|
this is not a GL646 (bDeviceClass = 255, bInterfaceClass = 255)
|
|
checking for GL646_HP ...
|
|
this is not a GL646_HP (bcdUSB = 0x200)
|
|
checking for GL660+GL646 ...
|
|
this is not a GL660+GL646 (bDeviceClass = 255, bInterfaceClass =
|
|
255)
|
|
checking for GL841 ...
|
|
this is not a GL841 (reg 0x38 != 0x15)
|
|
checking for ICM532B ...
|
|
check 2, this is not a ICM532B (bcdUSB = 0x200)
|
|
<Couldn't determine the type of the USB chip>
|
|
|
|
found USB scanner (vendor=0x03f0 [Hewlett-Packard], product=0x1305 [hp scanjet scanner]) at libusb:001:002
|
|
|
|
</pre>
|
|
|
|
<h1>Want to add or correct information?</h1>
|
|
<p>
|
|
If anything is wrong or missing on this page please <a href="/bugs.html">file a bug report</a>
|
|
or use the <a href="http://www.meier-geinitz.de:80/tinc?key=rDoQ7lrj&formname=adddev" target="_top">the
|
|
form for adding an unsupported device</a>.
|
|
</p>
|
|
<p>
|
|
If you own an unsupported scanner, please send as much information as
|
|
possible. Especially the output of <em>sane-find-scanner -v -v</em>
|
|
and/or <em>cat /proc/scsi/scsi</em> (for SCSI scanners) or <em>cat
|
|
/proc/bus/usb/devices</em> (for USB scanners) can help. If you dare to
|
|
open the scanner, have a look at the text that's printed on the
|
|
chips. That may help to identify the chipset. If you know that the
|
|
scanner is similar to another one (e.g. supported by the same Windows
|
|
driver), please also mention this fact.
|
|
</p>
|
|
|
|
<h1><a href="/manufacturers.html">Information for Manufacturers</a></h1>
|
|
<p>
|
|
Are you a manufacturer or vendor of scanners and one of your scanners is
|
|
not supported by SANE yet? In this case please have a look at our <a
|
|
href="/manufacturers.html">information for manufacturers</a>.
|
|
</p>
|
|
|
|
<h1>Links</h1>
|
|
<ul>
|
|
<li>
|
|
General information on how to <a href="/contrib.html">contribute to SANE</a>, e.g. by writing
|
|
backends
|
|
</li>
|
|
<li>
|
|
<a
|
|
href="/cgi-bin/driver.pl">Scanner
|
|
search engine</a>
|
|
</li>
|
|
<li>
|
|
<a href="http://www.sane-project.org/">SANE homepage</a>
|
|
</li>
|
|
</ul>
|
|
|
|
<hr>
|
|
|
|
<p>
|
|
<a href="/">SANE homepage</a><br>
|
|
<a href="/imprint.html">Contact</a>
|
|
</p>
|
|
<p>
|
|
<font size="-1">$Date$ $Author$</font>
|
|
</p>
|
|
</body>
|
|
|
|
</html>
|