kopia lustrzana https://gitlab.com/sane-project/website
133 wiersze
5.1 KiB
HTML
133 wiersze
5.1 KiB
HTML
<HTML>
|
|
<HEAD>
|
|
<TITLE>sane-canon_lide70.5</TITLE>
|
|
</HEAD>
|
|
<BODY BGCOLOR=#FFFFFF TEXT=#000000><H1 ALIGN=CENTER><IMG SRC="/images/sane.png" HEIGHT=117 WIDTH=346></H1>
|
|
<H1>sane-canon_lide70.5</H1>
|
|
<HR>
|
|
<PRE>
|
|
<!-- Manpage converted by man2html 3.0.1 -->
|
|
<B><A HREF="sane-canon_lide70.5.html">sane-canon_lide70(5)</A></B> SANE Scanner Access Now Easy <B><A HREF="sane-canon_lide70.5.html">sane-canon_lide70(5)</A></B>
|
|
|
|
|
|
</PRE>
|
|
<H2>NAME</H2><PRE>
|
|
sane-canon_lide70 - SANE backend for the Canon LiDE 70 and 600(F) USB
|
|
flatbed scanners
|
|
|
|
|
|
</PRE>
|
|
<H2>DESCRIPTION</H2><PRE>
|
|
The <B>canon_lide70</B> library implements a SANE (Scanner Access Now Easy)
|
|
backend that provides access to the Canon Inc. CanoScan LiDE 70 and
|
|
600(F) flatbed scanners. The film unit of the LiDE 600F is not sup-
|
|
ported.
|
|
|
|
Due to Canon's unwillingness to provide scanner documentation, this
|
|
software was developed by analyzing the USB traffic of the Windows XP
|
|
driver. The precise meaning of the individual commands that are sent to
|
|
the scanner is known only to a very limited extent. Some sophistication
|
|
present in the Windows XP driver has been left out. There is, for exam-
|
|
ple, no active calibration.
|
|
|
|
Testers and reviewers are welcome. Send your bug reports and comments
|
|
to the sane-devel mailing list <I><sane-devel@alioth-lists.debian.net></I>.
|
|
|
|
|
|
</PRE>
|
|
<H2>CONFIGURATION</H2><PRE>
|
|
The <I>/usr/local/etc/sane.d/canon</I><B>_</B><I>lide70.conf</I> file identifies the LiDE 70
|
|
by its vendor code 0x04a9 and its product code 0x2225. For the LiDE
|
|
600(f) the product code is 0x2224.
|
|
|
|
|
|
</PRE>
|
|
<H2>BACKEND SPECIFIC OPTIONS</H2><PRE>
|
|
<B>Scan</B> <B>Mode:</B>
|
|
|
|
<B>--resolution</B> <B>75|150|300|600|1200</B> <B>[default</B> <B>600]</B>
|
|
Sets the resolution of the scanned image in dots per inch. Scan-
|
|
ning at 1200 dpi is not available on the LiDE 600(F) and it is
|
|
very slow on the LiDE 70.
|
|
|
|
<B>--mode</B> <B>Color|Gray|Lineart</B> <B>[default:</B> <B>Color]</B>
|
|
Selects the scan mode. Lineart means fully black and fully white
|
|
pixels only.
|
|
|
|
<B>--threshold</B> <B>0..100</B> <B>(in</B> <B>steps</B> <B>of</B> <B>1)</B> <B>[default</B> <B>75]</B>
|
|
Select minimum-brightness percentage to get a white point, rele-
|
|
vant only for Lineart
|
|
|
|
<B>--non-blocking[=(yes|no)]</B> <B>[inactive]</B>
|
|
This option has not yet been implemented. Scans are captured in
|
|
a temporary file with a typical size of 100MB.
|
|
|
|
<B>Geometry:</B>
|
|
|
|
<B>-l</B> <B>0..216.069</B> <B>[default</B> <B>0]</B>
|
|
Top-left x position of scan area in millimeters.
|
|
|
|
<B>-t</B> <B>0..297</B> <B>[default</B> <B>0]</B>
|
|
Top-left y position of scan area in millimeters.
|
|
|
|
<B>-x</B> <B>0..216.069</B> <B>[default</B> <B>80]</B>
|
|
Width of scan-area in millimeters.
|
|
|
|
<B>-y</B> <B>0..297</B> <B>[default</B> <B>100]</B>
|
|
Height of scan-area in millimeters.
|
|
|
|
|
|
</PRE>
|
|
<H2>FILES</H2><PRE>
|
|
<I>/usr/local/etc/sane.d/canon</I><B>_</B><I>lide70.conf</I>
|
|
The backend configuration file
|
|
|
|
<I>/usr/local/lib/sane/libsane-canon</I><B>_</B><I>lide70.a</I>
|
|
The static library implementing this backend.
|
|
|
|
<I>/usr/local/lib/sane/libsane-canon</I><B>_</B><I>lide70.so</I>
|
|
The shared library implementing this backend (present on systems
|
|
that support dynamic loading).
|
|
|
|
|
|
</PRE>
|
|
<H2>ENVIRONMENT</H2><PRE>
|
|
<B>SANE_DEBUG_CANON_LIDE70</B>
|
|
If the library was compiled with debug support enabled, this
|
|
environment variable controls the debug level for this backend.
|
|
Higher debug levels increase the verbosity of the output.
|
|
|
|
Example:
|
|
SANE_DEBUG_CANON_LIDE70=128 scanimage > /dev/null
|
|
|
|
|
|
</PRE>
|
|
<H2>KNOWN PROBLEMS</H2><PRE>
|
|
At low resolutions (75 and 150 dpi, implying high slider speeds) the
|
|
LiDE 70 misses the top one millimeter of the scan area. This can be
|
|
remedied by shifting the document one millimeter downward, in cases
|
|
where such precision matters. Note that <B><A HREF="xsane.1.html">xsane(1)</A></B> uses the 75 dpi mode
|
|
for prescans. The problem is worse on the LiDE 600(F), where the offset
|
|
is five millimeters.
|
|
|
|
|
|
</PRE>
|
|
<H2>SEE ALSO</H2><PRE>
|
|
<B><A HREF="sane.7.html">sane(7)</A></B>, <B><A HREF="sane-usb.5.html">sane-usb(5)</A></B>, <B><A HREF="sane-find-scanner.1.html">sane-find-scanner(1)</A></B>, <B><A HREF="scanimage.1.html">scanimage(1)</A></B>, <B><A HREF="xsane.1.html">xsane(1)</A></B>,
|
|
http://www.juergen-ernst.de/info_sane.html
|
|
|
|
|
|
</PRE>
|
|
<H2>AUTHOR</H2><PRE>
|
|
pimvantend, building upon pioneering work by Juergen Ernst.
|
|
|
|
22 Aug 2020 <B><A HREF="sane-canon_lide70.5.html">sane-canon_lide70(5)</A></B>
|
|
</PRE>
|
|
<HR>
|
|
<ADDRESS>
|
|
Man(1) output converted with
|
|
<a href="http://www.oac.uci.edu/indiv/ehood/man2html.html">man2html</a>
|
|
</ADDRESS>
|
|
</BODY>
|
|
</HTML>
|