<h1>Re: Calibration problem on UMAX Astra 1220S</h1>
|
||
<b>Oliver Rauch</b> (<a href="mailto:oliver.rauch@Wolfsburg.DE"><i>oliver.rauch@Wolfsburg.DE</i></a>)<br>
|
||
<i>Tue, 23 Mar 1999 13:08:48 +0100</i>
|
||
<p>
|
||
<ul>
|
||
<li> <b>Messages sorted by:</b> <a href="date.html#221">[ date ]</a><a href="index.html#221">[ thread ]</a><a href="subject.html#221">[ subject ]</a><a href="author.html#221">[ author ]</a>
|
||
<!-- next="start" -->
|
||
<li> <b>Next message:</b> <a href="0222.html">wolfgang Rapp: "Re: xsane-0.18 available"</a>
|
||
<li> <b>Previous message:</b> <a href="0220.html">Dean Martin Townsley: "Calibration problem on UMAX Astra 1220S"</a>
|
||
<li> <b>Maybe in reply to:</b> <a href="0220.html">Dean Martin Townsley: "Calibration problem on UMAX Astra 1220S"</a>
|
||
<!-- nextthread="start" -->
|
||
<li> <b>Next in thread:</b> <a href="0237.html">Oliver Rauch: "Re: Calibration problem on UMAX Astra 1220S"</a>
|
||
<!-- reply="end" -->
|
||
</ul>
|
||
<!-- body="start" -->
|
||
Dean Martin Townsley wrote:<br>
|
||
<p>
|
||
<i>> Hi all,</i><br>
|
||
<i>> My problem with the calibration is simple: I can't get it to perform the</i><br>
|
||
<i>> calibration. I'm using sane 1.00 with the build-1 patch for the umax drivers</i><br>
|
||
<i>> and xsane 0.18 for the frontend (tried xscanimage too).</i><br>
|
||
<i>> I stuck a debug message in the code to supplement the messages already</i><br>
|
||
<i>> there and found that dev->do_calibration was zero when the scan process went</i><br>
|
||
<i>> through the do_calibration() function even when the box for "Quality</i><br>
|
||
<i>> Calibration" was checked in the interface. The code checks and to me seems</i><br>
|
||
<i>> to only perform the calibration if this is nonzero. I don't know if this is</i><br>
|
||
<i>> a problem in the driver itself or somewhere else but both xsane and</i><br>
|
||
<i>> xscanimage exhibit the same problem. That's as far as I got, I have final</i><br>
|
||
<i>> exams for the next two days (take homes) so I won't be able to fiddle again</i><br>
|
||
<i>> until after that probably, but I figured I'd say something so someone with</i><br>
|
||
<i>> better knowledge of the code can maybe investigate.</i><br>
|
||
<i>></i><br>
|
||
<i>> oh, btw, /proc/scsi/scsi says</i><br>
|
||
<i>> Host: scsi0 Channel: 00 Id: 05 Lun: 00</i><br>
|
||
<i>> Vendor: UMAX Model: Astra 1220S Rev: V1.1</i><br>
|
||
<i>> Type: Scanner ANSI SCSI revision: 02</i><br>
|
||
<i>></i><br>
|
||
<i>> Which I presume means it's firmware 1.1, (out of a possible 1.5, ugh).</i><br>
|
||
<i>></i><br>
|
||
<p>
|
||
Hi Dean,<br>
|
||
<p>
|
||
like described in the sane-umax-docs the quality calibration does not work with<br>
|
||
all scanners!<br>
|
||
<p>
|
||
What happens or does not happen if you enable quality calibration?<br>
|
||
<p>
|
||
Background:<br>
|
||
There are some problems with calibration by driver. UMAX uses a different<br>
|
||
kind of calibration for each scanner model and firmware. I only know the one of<br>
|
||
the Umax Supervista S12 with firmware 2.0.<br>
|
||
<p>
|
||
If you set the quality calibration button, the driver requests a quality<br>
|
||
calibration<br>
|
||
from the scanner. If the scanner is not able to do the quality calibration on<br>
|
||
its own,<br>
|
||
it requests the driver to do this. In that case do_calibration is set in the<br>
|
||
driver.<br>
|
||
Then the scanner sends the calibration data, the driver does the calibration and<br>
|
||
<p>
|
||
sends back the calibration data.<br>
|
||
<p>
|
||
If the scanner does not request that the driver has to do the calibration, there<br>
|
||
is<br>
|
||
nothing what the driver can do.<br>
|
||
<p>
|
||
Bye<br>
|
||
Oliver<br>
|
||
<p>
|
||
<pre>
|
||
--
|
||
EMAIL: <a href="mailto:Oliver.Rauch@Wolfsburg.DE">Oliver.Rauch@Wolfsburg.DE</a>
|
||
WWW: <a href="http://www.wolfsburg.de/~rauch">http://www.wolfsburg.de/~rauch</a>
|
||
<p>
|
||
<p>
|
||
<p>
|
||
<p>
|
||
<pre>
|
||
--
|
||
Source code, list archive, and docs: <a href="http://www.mostang.com/sane/">http://www.mostang.com/sane/</a>
|
||
To unsubscribe: echo unsubscribe sane-devel | mail <a href="mailto:majordomo@mostang.com">majordomo@mostang.com</a>
|
||
</pre>
|
||
<!-- body="end" -->
|
||
<p>
|
||
<ul>
|
||
<!-- next="start" -->
|
||
<li> <b>Next message:</b> <a href="0222.html">wolfgang Rapp: "Re: xsane-0.18 available"</a>
|
||
<li> <b>Previous message:</b> <a href="0220.html">Dean Martin Townsley: "Calibration problem on UMAX Astra 1220S"</a>
|
||
<li> <b>Maybe in reply to:</b> <a href="0220.html">Dean Martin Townsley: "Calibration problem on UMAX Astra 1220S"</a>
|
||
<!-- nextthread="start" -->
|
||
<li> <b>Next in thread:</b> <a href="0237.html">Oliver Rauch: "Re: Calibration problem on UMAX Astra 1220S"</a>
|
||
<!-- reply="end" -->
|
||
</ul>
|