<H2>DESCRIPTION</H2><PRE>
|
|
The <B>canon_lide70</B> library implements a SANE (Scanner Access Now Easy)
|
|
backend that provides access to the Canon Inc. CanoScan LiDE 70 flatbed
|
|
scanner.
|
|
|
|
Due to Canon's unwillingness to provide scanner documentation, this
|
|
software was developed by analyzing the USB traffic of the Windows XP
|
|
driver. The precise meaning of the individual commands that are sent to
|
|
the scanner is known only to a very limited extent. Some sophistication
|
|
present in the Windows XP driver has been left out. There is, for exam-
|
|
ple, no active calibration.
|
|
|
|
TESTERS ARE WELCOME. Send your bug reports and comments to the
|
|
sane-devel mailing list <sane-devel@alioth-lists.debian.net>
|
|
|
|
The <B>Canoscan</B> <B>LiDE</B> <B>600</B> (or 600f, with film unit) is closely related to
|
|
the LiDE 70, but it does not work with this backend. Support for the
|
|
LiDE 600 will be added by the end of 2020.
|
|
|
|
|
|
</PRE>
|
|
<H2>CONFIGURATION</H2><PRE>
|
|
The <I>/usr/local/etc/sane.d/canon</I><B>_</B><I>lide70.conf</I> file identifies the LiDE 70
|
|
by its vendor code 0x04a9 and its product code 0x2225. For the LiDE
|
|
600(f) the product code would be 0x2224.
|
|
|
|
|
|
</PRE>
|
|
<H2>BACKEND SPECIFIC OPTIONS</H2><PRE>
|
|
<B>Scan</B> <B>Mode:</B>
|
|
|
|
--resolution 75|150|300|600|1200 [default 600]
|
|
Sets the resolution of the scanned image in dots per inch.
|
|
Scanning at 1200 dpi is very slow.
|
|
|
|
--mode Color|Gray|Lineart [default: Color]
|
|
Selects the scan mode. Lineart means fully black and fully
|
|
white pixels only.
|
|
|
|
--threshold 0..100 (in steps of 1) [default 75]
|
|
Select minimum-brightness percentage to get a white point, rel-
|
|
evant only for Lineart
|
|
|
|
--non-blocking[=(yes|no)] [inactive]
|
|
This option has not yet been implemented. Scans are captured in
|
|
a temporary file with a typical size of 100MB.
|
|
|
|
<B>Geometry:</B>
|
|
|
|
-l 0..216.069 [default 0]
|
|
Top-left x position of scan area in millimeters.
|
|
|
|
-t 0..297 [default 0]
|
|
Top-left y position of scan area in millimeters.
|
|
|
|
-x 0..216.069 [default 80]
|
|
Width of scan-area in millimeters.
|
|
|
|
-y 0..297 [default 100]
|
|
Height of scan-area in millimeters.
|
|
|
|
|
|
</PRE>
|
|
<H2>FILES</H2><PRE>
|
|
<I>/usr/local/etc/sane.d/canon</I><B>_</B><I>lide70.conf</I>
|
|
The backend configuration file
|
|
|
|
<I>/usr/local/lib/sane/libsane-canon</I><B>_</B><I>lide70.a</I>
|
|
The static library implementing this backend.
|
|
|
|
<I>/usr/local/lib/sane/libsane-canon</I><B>_</B><I>lide70.so</I>
|
|
The shared library implementing this backend (present on systems
|
|
that support dynamic loading).
|
|
|
|
|
|
</PRE>
|
|
<H2>ENVIRONMENT</H2><PRE>
|
|
<B>SANE_DEBUG_CANON_LIDE70</B>
|
|
If the library was compiled with debug support enabled, this
|
|
environment variable controls the debug level for this backend.
|
|
Higher debug levels increase the verbosity of the output.
|
|
|
|
Example:
|
|
SANE_DEBUG_CANON_LIDE70=128 scanimage > /dev/null
|
|
|
|
|
|
</PRE>
|
|
<H2>KNOWN PROBLEMS</H2><PRE>
|
|
At low resolutions (75 and 150 dpi, implying high slider speeds) the
|
|
scanner misses the top one millimeter of the scan area. This can be
|
|
remedied by shifting the document one millimeter downward, in cases
|
|
where such precision matters. Note that xsane uses the 75 dpi mode for
|
|
prescans.
|
|
|
|
It is recommended that in xsane the gamma value be set to approximately
|
|
1.5 to get more realistic colors. This also wipes out some artifacts
|
|
caused by the lack of real calibration.
|
|
|
|
|
|
</PRE>
|
|
<H2>SEE ALSO</H2><PRE>
|
|
<B><A HREF="sane.7.html">sane(7)</A></B>, <B><A HREF="sane-usb.5.html">sane-usb(5)</A></B>, <B><A HREF="sane-find-scanner.1.html">sane-find-scanner(1)</A></B>, <B><A HREF="scanimage.1.html">scanimage(1)</A></B>
|
|
http://www.juergen-ernst.de/info_sane.html
|
|
|
|
|
|
</PRE>
|
|
<H2>AUTHOR</H2><PRE>
|
|
pimvantend, building upon pioneering work by Juergen Ernst.
|
|
|
|
26 Nov 2019 <B><A HREF="sane-canon_lide70.5.html">sane-canon_lide70(5)</A></B>
|
|
</PRE>
|
|
<HR>
|
|
<ADDRESS>
|
|
Man(1) output converted with
|
|
<a href="http://www.oac.uci.edu/indiv/ehood/man2html.html">man2html</a>
|
|
</ADDRESS>
|
|
</BODY>
|
|
</HTML>
|