<!-- received="Tue Sep 28 09:29:24 1999 PDT" -->
|
||
<!-- sent="28 Sep 1999 18:31:02 +0200" -->
|
||
<!-- name="Camille DIOU" -->
|
||
<!-- email="diou@lirmm.fr" -->
|
||
<!-- subject="Re: ppSCSI and Microtek Phantom 330 CX" -->
|
||
<!-- id="" -->
|
||
<!-- inreplyto="Sun, 26 Sep 1999 00:40:34 +0200"" -->
|
||
<title>sane-devel: Re: ppSCSI and Microtek Phantom 330 CX</title>
|
||
<h1>Re: ppSCSI and Microtek Phantom 330 CX</h1>
|
||
<b>Camille DIOU</b> (<a href="mailto:diou@lirmm.fr"><i>diou@lirmm.fr</i></a>)<br>
|
||
<i>28 Sep 1999 18:31:02 +0200</i>
|
||
<p>
|
||
<ul>
|
||
<li> <b>Messages sorted by:</b> <a href="date.html#181">[ date ]</a><a href="index.html#181">[ thread ]</a><a href="subject.html#181">[ subject ]</a><a href="author.html#181">[ author ]</a>
|
||
<!-- next="start" -->
|
||
<li> <b>Next message:</b> <a href="0182.html">Mitchell, Sean: "Mustek MFS 6000CX Problems"</a>
|
||
<li> <b>Previous message:</b> <a href="0180.html">Mitch Wikoff: "RE: Choice of SCSI Controller."</a>
|
||
<li> <b>In reply to:</b> <a href="0163.html">Michele Bini: "Re: ppSCSI and Microtek Phantom 330 CX"</a>
|
||
<!-- nextthread="start" -->
|
||
<!-- reply="end" -->
|
||
</ul>
|
||
<!-- body="start" -->
|
||
Hi Bernd and Michele,<br>
|
||
<p>
|
||
* "MB" = Michele Bini wrote on Sun, Sep 26, 1999 at 00:40:34 +0200:<br>
|
||
MB> On Wed, Sep 22, 1999 at 06:59:22PM +0200, Bernd Schroeder<br>
|
||
MB> wrote:<br>
|
||
<p>
|
||
<i> >> It is possible that it doesn't work. According to Michele Bini</i><br>
|
||
<i> >> the Phantom 330cx doesn't understand one of the SCSI</i><br>
|
||
<i> >> commands. This command is not executed for the Phantom 330cx</i><br>
|
||
<i> >> during a normal scan. But it is still used in the calibration</i><br>
|
||
<i> >> process. If you experience problems you must remove the call to</i><br>
|
||
<i> >> scsi_wait_for_image() in the do-calibration() function.</i><br>
|
||
<p>
|
||
MB> I have tried this, but the scan does not start (scanner led<br>
|
||
MB> blinks) and the module gives errors and may eventually OOPS<br>
|
||
MB> (i'm not using the latest ppscsi version).<br>
|
||
<p>
|
||
Here are my latest experiences with this scanner, ppSCSI v0.91 and<br>
|
||
microtek2 pre-0.8 backend.<br>
|
||
<p>
|
||
When the calibration option is on, as you already know, the scan<br>
|
||
doesn't start. <br>
|
||
<p>
|
||
After having removed the scsi_wait_for_image() call in microtek2.c,<br>
|
||
the scan starts but the head goes forward/backward again and don't<br>
|
||
stop, whatever the 'no-backtrace-option' is set or not, and with all<br>
|
||
the different scan modes (lineart, gray or color).<br>
|
||
<p>
|
||
Thus, the best way to use this scanner is the default one, with<br>
|
||
the 'no-backtrace-option' set and the 'calibration-by-backend' option<br>
|
||
unset. <br>
|
||
In this case, everything seems to work correctly, but the offset<br>
|
||
problem remains :-( <br>
|
||
<p>
|
||
<pre>
|
||
--
|
||
Regards,
|
||
<p>
|
||
Camille Diou
|
||
<p>
|
||
<p>
|
||
<pre>
|
||
--
|
||
Source code, list archive, and docs: <a href="http://www.mostang.com/sane/">http://www.mostang.com/sane/</a>
|
||
To unsubscribe: echo unsubscribe sane-devel | mail <a href="mailto:majordomo@mostang.com">majordomo@mostang.com</a>
|
||
</pre>
|
||
<!-- body="end" -->
|
||
<p>
|
||
<ul>
|
||
<!-- next="start" -->
|
||
<li> <b>Next message:</b> <a href="0182.html">Mitchell, Sean: "Mustek MFS 6000CX Problems"</a>
|
||
<li> <b>Previous message:</b> <a href="0180.html">Mitch Wikoff: "RE: Choice of SCSI Controller."</a>
|
||
<li> <b>In reply to:</b> <a href="0163.html">Michele Bini: "Re: ppSCSI and Microtek Phantom 330 CX"</a>
|
||
<!-- nextthread="start" -->
|
||
<!-- reply="end" -->
|
||
</ul>
|