<H2>NAME</H2><PRE>
|
|
scanadf - acquire multiple images from a scanner equipped with an ADF
|
|
|
|
|
|
</PRE>
|
|
<H2>SYNOPSIS</H2><PRE>
|
|
<B>scanadf</B> [<B>-d</B>|<B>--device-name</B> <I>dev</I>] [<B>-h</B>|<B>--help</B>] [<B>-L</B>|<B>--list-devices</B>]
|
|
[<B>-v</B>|<B>--verbose</B>] [<B>-V</B>|<B>--version</B>] [<B>-o</B>|<B>--output-file</B> <I>name</I>] [<B>-S</B>|<B>--scan-script</B>
|
|
<I>name</I>] [<B>-s</B>|<B>--start-count</B> <I>num</I>] [<B>-e</B>|<B>--end-count</B> <I>num</I>] [<B>-r</B>|<B>--raw</B>] [<I>device-</I>
|
|
<I>specific-options</I>]
|
|
|
|
|
|
</PRE>
|
|
<H2>DESCRIPTION</H2><PRE>
|
|
<B>scanadf</B> is a command-line interface to control image acquisition
|
|
devices which are capable of returning a series of images (e.g. a scan-
|
|
ner with an automatic document feeder (ADF)). The device is controlled
|
|
via command-line options. After command-line processing, <B>scanadf</B> nor-
|
|
mally proceeds to acquire a series of images until the device returns
|
|
the <B>SANE_STATUS_NO_DOCS</B> status code.
|
|
|
|
The images are written to output files, specified by the <B>--output-file</B>
|
|
option. These files are typically written in one of the PNM (portable
|
|
aNyMaP) formats (PBM for black-and-white images, PGM for grayscale
|
|
images, and PPM for color images). Several optional frame formats
|
|
(SANE_FRAME_JPEG, SANE_FRAME_G31D, SANE_FRAME_G32D, SANE_FRAME_G42D,
|
|
and SANE_FRAME_TEXT) are supported. In each case, the data is written
|
|
out to the output file as-is without a header. Unrecognized frame for-
|
|
mats are handled in the same way, although a warning message is printed
|
|
in verbose mode.
|
|
|
|
Typically, the optional frame formats are used in conjunction with a
|
|
scan script (specified by the <B>--scanscript</B> option) which is invoked for
|
|
each acquired image. The script is provided with a series of environ-
|
|
ment variables which describe the parameters and format of the image
|
|
file.
|
|
|
|
<B>scanadf</B> accesses image acquisition devices through the SANE (Scanner
|
|
Access Now Easy) interface and can thus support any device for which
|
|
there exists a SANE backend (try "apropos sane-" to get a list of
|
|
available backends).
|
|
|
|
|
|
</PRE>
|
|
<H2>OPTIONS</H2><PRE>
|
|
The <B>-d</B> or <B>--device-name</B> options must be followed by a SANE device-name.
|
|
A (partial) list of available devices can be obtained with the <B>--list-</B>
|
|
<B>devices</B> option (see below). If no device-name is specified explicitly,
|
|
<B>scanadf</B> will attempt to open the first available device.
|
|
|
|
The <B>-h</B> or <B>--help</B> options request help information. The information is
|
|
printed on standard output and in this case, no attempt will be made to
|
|
acquire an image.
|
|
|
|
The <B>-L</B> or <B>--list-devices</B> option requests a (partial) list of devices
|
|
that are available. The list is not complete since some devices may be
|
|
available, but are not listed in any of the configuration files (which
|
|
are typically stored in directory /usr/local/etc/sane.d). This is par-
|
|
ticularly the case when accessing scanners through the network. If a
|
|
device is not listed in a configuration file, the only way to access it
|
|
is by its full device name. You may need to consult your system admin-
|
|
istrator to find out the names of such devices.
|
|
|
|
The <B>-v</B> or <B>--verbose</B> options increase the verbosity of the operation of
|
|
<B>scanadf.</B> The option may be specified repeatedly, each time increasing
|
|
the verbosity level.
|
|
|
|
The <B>-V</B> or <B>--version</B> option requests that <B>scanadf</B> print the program and
|
|
package name, as well as the version number of the SANE distribution
|
|
that it came with.
|
|
|
|
The <B>-o</B> or <B>--output-file</B> option specifies a format string used to gener-
|
|
ate the name of file to write the image data to. You can use %d
|
|
replacement in the output file name; this will be replaced with the
|
|
current page number. The default format string is image-%04d.
|
|
|
|
The <B>-S</B> or <B>--scan-script</B> option specifies the name of script to run
|
|
after each scanned image is acquired. The script receives the name of
|
|
the image output file as its first and only command line argument.
|
|
Additionally the scan script can reference the following environment
|
|
variables to get information about the parameters of the image.
|
|
|
|
<B>SCAN_RES</B> - the image resolution (in DPI)
|
|
<B>SCAN_WIDTH</B> - the image width (in pixels)
|
|
<B>SCAN_HEIGHT</B> - the image height (in pixels)
|
|
<B>SCAN_DEPTH</B> - the image bit-depth (in bits)
|
|
<B>SCAN_FORMAT</B> - a string representing the image format (e.g. gray,
|
|
g42d, text, etc)
|
|
<B>SCAN_FORMAT_ID</B> - the numeric image format identifier
|
|
|
|
The <B>-s</B> or <B>--start-count</B> option specifies the page number of first
|
|
scanned image.
|
|
|
|
The <B>-e</B> or <B>--end-count</B> option specifies the last page number to scan.
|
|
Using this option, you can request a specific number of pages to be
|
|
scanned, rather than scanning until there are no more images available.
|
|
|
|
The <B>-r</B> or <B>--raw</B> option specifies that the raw image data be written to
|
|
the output file as-is without interpretation. This disables the writ-
|
|
ing of the PNM header for basic frame types. This feature is usually
|
|
used in conjunction with the <B>--scan-script</B> option where the scan script
|
|
uses the environment variables to understand the format and parameters
|
|
of the image and converts the file to a more useful format. NOTE: With
|
|
support for the optional frame types and the default handling of unrec-
|
|
ognized frametypes, this option becomes less and less useful.
|
|
|
|
As you might imagine, much of the power of <B>scanadf</B> comes from the fact
|
|
that it can control any SANE backend. Thus, the exact set of command-
|
|
line options depends on the capabilities of the selected device. To
|
|
see the options for a device named <I>dev</I>, invoke <B>scanadf</B> via a command-
|
|
line of the form:
|
|
|
|
scanadf --help --device <I>dev</I>
|
|
|
|
The documentation for the device-specific options printed by <B>--help</B> is
|
|
explained in the manual page for <B>scanimage.</B>
|
|
|
|
|
|
</PRE>
|
|
<H2>FILES</H2><PRE>
|
|
<I>/usr/local/etc/sane.d</I>
|
|
This directory holds various configuration files. For details,
|
|
please refer to the manual pages listed below.
|
|
|
|
|
|
</PRE>
|
|
<H2>SEE ALSO</H2><PRE>
|
|
<B><A HREF="scanimage.1.html">scanimage(1)</A></B>, <B><A HREF="xscanimage.1.html">xscanimage(1)</A></B>, <B><A HREF="sane.7.html">sane(7)</A></B>
|
|
|
|
|
|
</PRE>
|
|
<H2>AUTHOR</H2><PRE>
|
|
scanadf is an adaptation by Tom Martone of scanimage by David Mos-
|
|
berger, Andreas Beck, and Gordon Matzigkeit following closely the
|
|
features of bnhscan by Sean Reifschneider of tummy.com, ltd.
|
|
|
|
|
|
</PRE>
|
|
<H2>BUGS</H2><PRE>
|
|
Please send reports to <I>sane-devel@lists.alioth.debian.org</I>.
|
|
|
|
This program relies on the backend to return the <B>SANE_STATUS_NO_DOCS</B>
|
|
status code when the automatic document feeder is out of paper. Use of
|
|
this program with backends that do not support ADFs (e.g. flatbed scan-
|
|
ners) will likely result in repeated scans of the same document. In
|
|
this case, it is essential to use the start-count and end-count to con-
|
|
trol the number of images acquired.
|
|
|
|
Only a subset of the SANE backends support feeders and return SANE_STA-
|
|
TUS_NO_DOCS appropriately. Backends which are known to work at this
|
|
time are:
|
|
|
|
<B>sane-bh</B> - Bell+Howell Copiscan II series scanners.
|
|
<B>sane-hp</B> - Hewlett Packard scanners. A patch to the sane-hp
|
|
backend is necessary. The --scantype=ADF option must be speci-
|
|
fied (earlier versions of the backend used the --scan-from-adf
|
|
option, instead).
|
|
<B>sane-umax</B> - UMAX scanners. Support exists in build 12 and
|
|
later. The --source="Automatic Document Feeder" option must be
|
|
specified.
|
|
|
|
15 Sep 1999 <B><A HREF="scanadf.1.html">scanadf(1)</A></B>
|
|