<H2>NAME</H2><PRE>
|
||
sane-microtek2 - SANE backend for Microtek scanners with SCSI-2 command
|
||
set
|
||
|
||
|
||
</PRE>
|
||
<H2>DESCRIPTION</H2><PRE>
|
||
The <B>sane-microtek2</B> library implements a SANE (Scanner Access Now Easy)
|
||
backend that provides access to Microtek scanners with a SCSI-2 command
|
||
set. This backend can be considered alpha to beta. Some scanner models
|
||
are reported to work well, others not. New development versions of this
|
||
backend can be obtained from <B>http://karstenfestag.gmxhome.de</B>
|
||
|
||
There exists a different backend for Microtek scanners with SCSI-1 com‐
|
||
mand set. Refer to <B><A HREF="sane-microtek.5.html">sane-microtek(5)</A></B> for details.
|
||
|
||
And there is work in progress for the ScanMaker 3600. See
|
||
<B>http://sourceforge.net/projects/sm3600</B>
|
||
|
||
At present, the following scanners are known positively to work with
|
||
this backend:
|
||
|
||
Vendor Product id Remark
|
||
--------------------------------------------------------------------
|
||
Microtek E3+ Parport and SCSI
|
||
Microtek X6 SCSI
|
||
Microtek X6EL SCSI
|
||
Microtek X6USB USB
|
||
Microtek ScanMaker V300 Parport and SCSI
|
||
Microtek ScanMaker V310 Parport and SCSI
|
||
Microtek ScanMaker V600 Parport and SCSI
|
||
Microtek ScanMaker 330 SCSI
|
||
Microtek ScanMaker 630 SCSI
|
||
Microtek ScanMaker 636 SCSI
|
||
Microtek ScanMaker 9600XL SCSI; only flatbed mode?
|
||
Microtek Phantom 330CX Parport
|
||
Microtek SlimScan C3 Parport
|
||
Microtek SlimScan C6 USB
|
||
Microtek Phantom 636 SCSI
|
||
Microtek Phantom 636CX Parport
|
||
Microtek V6USL SCSI and USB
|
||
Microtek V6UPL USB; not stable
|
||
Microtek X12USL SCSI; only 8bit color, work in progress
|
||
Vobis HighScan SCSI (E3+ based models)
|
||
Scanport SQ300 Parport?
|
||
Scanport SQ4836 SCSI
|
||
Scanpaq SQ2030 Parport
|
||
|
||
Additional information can be found at <B>http://www.sane-project.org/</B>.
|
||
|
||
If you own a Microtek scanner other than the ones listed above, it may
|
||
or may not work with SANE! Because equal scanners are sold under dif‐
|
||
ferent names in different countries your model may be equivalent to one
|
||
of the above.
|
||
|
||
The parport scanners work with the ppscsi + onscsi kernel modules. See
|
||
<I>http://cyberelk.net/tim/parport/ppscsi.html</I> and <I>http://penguin-</I>
|
||
<I>breeder.org/kernel/download/</I>.
|
||
|
||
The USB scanners work with the microtek kernel module. You may have to
|
||
add the vendor and model codes to microtek.c if they aren't yet listed
|
||
there.
|
||
|
||
Both parport and USB scanners need the generic SCSI support, so check
|
||
if you have loaded the scsi_mod and sg modules!
|
||
|
||
If you try your scanner for the first time keep an eye on it. If it
|
||
gets commands that it doesn't understand the scanhead may go beyond the
|
||
scan area. The scanner then makes strange noises. In this case immedi‐
|
||
ately switch off the scanner or disconnect its power cable to prevent
|
||
damages!
|
||
|
||
If your scanner is a different one than the models mentioned above and
|
||
it is working please tell the author about it. It would be nice if you
|
||
add a logfile to this information (creation of the logfile: see below).
|
||
|
||
If your scanner is not working properly you also should create a log‐
|
||
file and send it to the author. He will use the information to improve
|
||
the backend and possibly make your scanner work.
|
||
|
||
How to create the logfile?
|
||
|
||
- put the line
|
||
"option dump 2" into your <I>microtek2.conf</I> file or change the
|
||
existing "option dump" to "2"
|
||
|
||
- in a terminal (bash) type
|
||
"export SANE_DEBUG_MICROTEK2=30" and then
|
||
"scanimage -l0 -t0 -x100 -y20 2>scan.log >sout.pnm"
|
||
You get two files: scan.log contains the logfile and sout.pnm
|
||
the scanned image (if there was scanned something). Zip them
|
||
before sending.
|
||
|
||
|
||
</PRE>
|
||
<H2>FRONTEND OPTIONS</H2><PRE>
|
||
This backend dynamically enables the options for the frontend, that are
|
||
supported by the scanner in dependence of the scanning-mode and other
|
||
options. Not supported options are disabled.
|
||
|
||
The following options are supported by the Microtek2-driver:
|
||
|
||
Color, grayscale, halftone and lineart scans.
|
||
|
||
Highlight, midtone, shadow, contrast, brightness, exposure time con‐
|
||
trol, gamma correction, threshold (dependent of the scan mode and the
|
||
scanner capabilities)
|
||
|
||
Transparency media adapter, automatic document feeder
|
||
|
||
Additional options can be enabled or disabled in the <I>microtek2.conf</I>
|
||
file. See the configuration section of this manpage.
|
||
|
||
|
||
</PRE>
|
||
<H2>DEVICE NAMES</H2><PRE>
|
||
This backend expects device names of the form:
|
||
|
||
<I>special</I>
|
||
|
||
Where <I>special</I> is the UNIX path-name for the special device that corre‐
|
||
sponds to the scanner. The special device name must be a generic SCSI
|
||
device or a symlink to such a device. Under Linux, such a device name
|
||
could be <I>/dev/sga</I> or <I>/dev/sge</I> for example.
|
||
|
||
|
||
</PRE>
|
||
<H2>CONFIGURATION</H2><PRE>
|
||
The configuration file for this backend resides in
|
||
<I>/usr/local/etc/sane.d/microtek2.conf</I>.
|
||
|
||
Its contents is a list of device names that correspond to Microtek
|
||
scanners with SCSI-2 interface. Empty lines and lines starting with a
|
||
hash mark (#) are ignored.
|
||
|
||
The configuration file may also contain options. Global options that
|
||
are valid for all devices are placed above the device names. Device-
|
||
specific options are placed under the device name. Note that, except
|
||
for option dump <n> and option strip-height <n>, the entry in the
|
||
microtek2.conf file only enables the corresponding option for being
|
||
showed in the frontend. There, in the frontend, you can switch the
|
||
options on and off. Currently the following options are supported:
|
||
|
||
option dump <n>
|
||
option strip-height <n>
|
||
option no-backtrack-option <on/off>
|
||
option lightlid-35 <on/off>
|
||
option toggle-lamp <on/off>
|
||
option lineart-autoadjust <on/off>
|
||
option backend-calibration <on/off>
|
||
option colorbalance-adjust <on/off>
|
||
|
||
<I>option</I> <I>dump</I> <I><n></I> enables printing of additional information about the
|
||
SCSI commands that are sent to the scanner to stderr. This option is
|
||
primarily useful for debugging purpose. This option has to be a global
|
||
option and is best placed at the top of the <I>microtek2.conf</I> file.
|
||
|
||
If n=1 the contents of the command blocks and the results for the
|
||
INQUIRY and READ SCANNER ATTRIBUTES command are printed to stderr.
|
||
|
||
If n=2 the contents of the command blocks for all other SCSI commands
|
||
are printed to stderr, too. If n=3 the contents of the gamma table is
|
||
printed, too. If n=4 all scan data is additionally printed to stderr.
|
||
|
||
The default is n=1.
|
||
|
||
<I>option</I> <I>strip-height</I> <I><n></I> , where <n> is a floating point number, limits
|
||
the amount of data that is read from the scanner with one read command.
|
||
The unit is inch and <n> defaults to 1.0, if this option is not set in
|
||
the configuration file. If less than <n> inch of data fit into the SCSI
|
||
buffer, then the smaller value is used and this option has no effect.
|
||
|
||
If your system has a big SCSI buffer and you want to make use of the
|
||
whole buffer, increase the value for <n>. For example, if <n> is set to
|
||
14.0, no restrictions apply for scanners with a letter, legal or A4
|
||
sized scan area.
|
||
|
||
The following options enable or disable additional frontend options. If
|
||
an option is set to <on> an appropriate option will appear in the fron‐
|
||
tend.
|
||
|
||
<I>option</I> <I>no-backtrack-option</I> <I><on/off></I> prevents the scanner head from mov‐
|
||
ing backwards between the read commands. This speeds up scanning. Try
|
||
it.
|
||
|
||
<I>option</I> <I>lightlid-35</I> <I><on/off></I> If you use the LightLid-35 transparency
|
||
adapter you get an advanced option which switches off the flatbed lamp
|
||
during the scan.
|
||
|
||
<I>option</I> <I>toggle-lamp</I> <I><on/off></I> You get a button in the frontend where you
|
||
can switch on and off the flatbed lamp.
|
||
|
||
<I>option</I> <I>lineart-autoadjust</I> <I><on/off></I> You can tell the backend to try to
|
||
determine a good value for the lineart threshold.
|
||
|
||
<I>option</I> <I>backend-calibration</I> <I><on/off></I> Some scanners (e.g. Phantom 330CX
|
||
and 636CX) need to have calibrated the data by the backend. Try this
|
||
option if you see vertical stripes in your pictures.
|
||
|
||
<I>option</I> <I>colorbalance-adjust</I> <I><on/off></I> Some scanners (e.g. Phantom 330CX
|
||
and 636CX) need to have corrected the color balance. If this option is
|
||
enabled you get advanced options where you can balance the colors. And
|
||
you will have a button to use the values that the firmware of the scan‐
|
||
ner provides.
|
||
|
||
A sample configuration file is shown below:
|
||
|
||
option dump 1
|
||
option strip-height 1.0
|
||
/dev/scanner
|
||
option no-backtrack-option on
|
||
# this is a comment
|
||
/dev/sge
|
||
option lightlid-35 on
|
||
|
||
This backend also supports the new configuration file format which
|
||
makes it easier to detect scanners under Linux. If you have only one
|
||
scanner it would be best to use the following configuration file for
|
||
this backend:
|
||
|
||
option dump 1
|
||
option strip-height 14.0
|
||
option no-backtrack-option on
|
||
option backend-calibration on
|
||
option lightlid-35 on
|
||
option toggle-lamp on
|
||
option lineart-autoadjust on
|
||
option colorbalance-adjust off
|
||
scsi * * Scanner
|
||
|
||
In this case all SCSI-Scanners should be detected automatically because
|
||
of the
|
||
|
||
scsi * * Scanner
|
||
|
||
line.
|
||
|
||
|
||
</PRE>
|
||
<H2>FILES</H2><PRE>
|
||
<I>/usr/local/etc/sane.d/microtek2.conf</I>
|
||
The backend configuration file.
|
||
|
||
<I>/usr/local/lib/sane/libsane-microtek2.a</I>
|
||
The static library implementing this backend.
|
||
|
||
<I>/usr/local/lib/sane/libsane-microtek2.so</I>
|
||
The shared library implementing this backend (present on systems
|
||
that support dynamic loading).
|
||
|
||
|
||
</PRE>
|
||
<H2>ENVIRONMENT</H2><PRE>
|
||
<B>SANE_DEBUG_MICROTEK2</B>
|
||
If the library was compiled with debug support enabled, this
|
||
environment variable controls the debug level for this backend.
|
||
E.g., a value of 255 requests all debug output to be printed.
|
||
Smaller levels reduce verbosity. To see error messages on stderr
|
||
set SANE_DEBUG_MICROTEK2 to 1 (Remark: The whole debugging lev‐
|
||
els should be better revised).
|
||
E.g. just say:
|
||
export SANE_DEBUG_MICROTEK2=128
|
||
|
||
|
||
</PRE>
|
||
<H2>SEE ALSO</H2><PRE>
|
||
<B><A HREF="sane-scsi.5.html">sane-scsi(5)</A></B>, <B><A HREF="sane.7.html">sane(7)</A></B>
|
||
|
||
|
||
</PRE>
|
||
<H2>AUTHORS</H2><PRE>
|
||
Bernd Schroeder (not active anymore)
|
||
Karsten Festag karsten.festag@gmx.de
|
||
|
||
13 Jul 2008 <B><A HREF="sane-microtek2.5.html">sane-microtek2(5)</A></B>
|
||
</PRE>
|
||
<HR>
|
||
<ADDRESS>
|
||
Man(1) output converted with
|
||
<a href="http://www.oac.uci.edu/indiv/ehood/man2html.html">man2html</a>
|
||
</ADDRESS>
|
||
</BODY>
|
||
</HTML>
|