<H2>DESCRIPTION</H2><PRE>
|
||
The <B>sane-hp</B> library implements a SANE (Scanner Access Now Easy) backend
|
||
that provides access to HP ScanJet scanners which support SCL (Scanner
|
||
Control Language by HP). The following scanners are known positively
|
||
to work with this backend:
|
||
|
||
Model: Product id: Interface:
|
||
---------- ----------- ----------
|
||
ScanJet Plus C9195A HP Parallel Interface Card
|
||
ScanJet IIc C1750A 3226 SCSI
|
||
ScanJet IIcx C2500A 3332 SCSI
|
||
ScanJet IIp C1790A SCSI
|
||
ScanJet 3C C2520A 3503 SCSI
|
||
ScanJet 3P C2570A 3406 SCSI
|
||
ScanJet 4C C2520A SCSI
|
||
ScanJet 4P C1130A 3540 SCSI
|
||
ScanJet 4100C C6290A USB
|
||
ScanJet 5P C5110A SCSI
|
||
ScanJet 5100C C5190A parallel port
|
||
ScanJet 5200C C7190A 3846 parallel port/USB
|
||
ScanJet 6100C C2520A 3644 SCSI
|
||
ScanJet 6200C C6270A 3828 SCSI/USB
|
||
ScanJet 6250C C6270A 3828 SCSI/USB
|
||
ScanJet 6300C C7670A SCSI/USB
|
||
ScanJet 6350C C7670A SCSI/USB
|
||
ScanJet 6390C C7670A SCSI/USB
|
||
PhotoSmart C5100A R029,R030,R032 SCSI
|
||
|
||
Support for models 5100C/5200C connected to the parallel port requires
|
||
the ppSCSI driver available at <I>http://cyberelk.net/tim/par<61></I><EFBFBD><EFBFBD>
|
||
<I>port/ppscsi.html</I> and <I>http://penguin-breeder.org/kernel/download/</I>.
|
||
|
||
Support for models 5200C/62X0C/63X0C connected to the USB require the
|
||
kernel scanner driver or libusb. See <B><A HREF="sane-usb.5.html">sane-usb(5)</A></B> for more details.
|
||
|
||
The "hp" backend no longer supports OfficeJet multi-function peripher‐
|
||
als. For these devices use the external "hpoj" backend in version 0.90
|
||
and later of the "HP OfficeJet Linux driver", available at
|
||
<I>http://hpoj.sourceforge.net</I>
|
||
|
||
Because Hewlett-Packard does no longer produce scanners that support
|
||
SCL (beside the OfficeJets), the above list of supported scanners is
|
||
complete. Other HP scanners are not supported by the "hp" backend, but
|
||
might be supported by another one. See <I>http://www.sane-project.org/</I>.
|
||
You can also watch the sane-devel mailing list at
|
||
<I>http://www.sane-project.org/mailing-lists.html</I>.
|
||
|
||
More details about the hp backend can be found on its homepage
|
||
<I>http://www.kirchgessner.net/sane.html</I>.
|
||
|
||
|
||
</PRE>
|
||
<H2>DEVICE NAMES</H2><PRE>
|
||
This backend expects device names of the form:
|
||
|
||
<I>special</I>
|
||
|
||
Where <I>special</I> is the UNIX path-name for the special device that corre‐
|
||
sponds to the scanner. For SCSI scanners the special device name must
|
||
be a generic SCSI device or a symlink to such a device. Under Linux,
|
||
such a device name could be <I>/dev/sga</I> or <I>/dev/sg2</I>, for example. If the
|
||
special device name contains "usb", "uscanner" or "ugen", it is assumed
|
||
that the scanner is connected by USB. For the HP ScanJet Plus the spe‐
|
||
cial device name must be the device that corresponds to the parallel
|
||
interface card that was shipped with the scanner. That is <I>/dev/hpscan</I>.
|
||
A special driver is required for this card. See
|
||
ftp://rvs.ctrl-c.liu.se/pub/wingel/hpscan for details. If the link does
|
||
not work, try ftp://sunsite.unc.edu/pub/Linux/kernel/patches/scanners.
|
||
|
||
|
||
</PRE>
|
||
<H2>CONFIGURATION</H2><PRE>
|
||
The contents of the <I>hp.conf</I> file is a list of options and device names
|
||
that correspond to HP ScanJet scanners. Empty lines and lines starting
|
||
with a hash mark (#) are ignored. See <B><A HREF="sane-scsi.5.html">sane-scsi(5)</A></B> and <B><A HREF="sane-usb.5.html">sane-usb(5)</A></B> on
|
||
details of what constitutes a valid device name.
|
||
|
||
Options specified in front of the first line that contains a device
|
||
name are defaults for all devices. Options specified below a line that
|
||
contains a device name apply just to the most recently mentioned
|
||
device.
|
||
|
||
Supported options are <B>connect-scsi</B>, <B>connect-device</B>,
|
||
<B>enable-image-buffering</B>, and <B>dumb-read</B>.
|
||
|
||
Option <B>connect-scsi</B> specifies that the scanner is connected to the sys‐
|
||
tem by SCSI. Input/output is performed using SCSI-commands. This is
|
||
the default. But if your SCSI device name contains "usb", "uscanner"
|
||
or "ugen", option connect-scsi must be specified. Otherwise it is
|
||
assumed that the scanner is connected by USB.
|
||
|
||
Option <B>connect-device</B> specifies that the scanner is connected to the
|
||
system by a special device. Input/output is performed by
|
||
read()/write()-operations on the device. This option must be used for
|
||
HP ScanJet Plus or scanners connected to USB which are accessed through
|
||
a named device (e.g. /dev/usb/scanner0). For device names that contain
|
||
"usb", "uscanner" or "ugen", it is not necessary to specify option con‐
|
||
nect-device.
|
||
|
||
Option <B>enable-image-buffering</B> stores the scanned image in memory before
|
||
passing it to the frontend. Could be used in case of forward/backward
|
||
moving scanner lamp.
|
||
|
||
Option <B>dumb-read</B> can be used to work around problems with "Error during
|
||
device I/O". These problems may occur with certain SCSI-to-USB convert‐
|
||
ers or Buslogic SCSI cards. The option should not be used for SCSI
|
||
devices which are working correctly. Otherwise startup of frontends
|
||
and changing parameters might be slower.
|
||
|
||
A sample configuration file is shown below:
|
||
|
||
/dev/scanner
|
||
# this is a comment
|
||
/dev/hpscan
|
||
option connect-device
|
||
|
||
/dev/scanner is typically a symlink to the actual SCSI scanner device.
|
||
|
||
|
||
</PRE>
|
||
<H2>FILES</H2><PRE>
|
||
<I>/usr/local/etc/sane.d/hp.conf</I>
|
||
The backend configuration file (see also description of
|
||
<B>SANE_CONFIG_DIR</B> below).
|
||
|
||
<I>/usr/local/lib/sane/libsane-hp.a</I>
|
||
The static library implementing this backend.
|
||
|
||
<I>/usr/local/lib/sane/libsane-hp.so</I>
|
||
The shared library implementing this backend (present on systems
|
||
that support dynamic loading).
|
||
|
||
<I>$HOME/.sane/calib-hp:<device>.dat</I>
|
||
Calibration data for HP PhotoSmart PhotoScanner that is
|
||
retrieved from the scanner after calibration. The data is
|
||
uploaded to the scanner at start of the backend if it is in
|
||
media mode 'print media' or if the media mode is changed to
|
||
'print media'.
|
||
|
||
|
||
</PRE>
|
||
<H2>ENVIRONMENT</H2><PRE>
|
||
<B>SANE_CONFIG_DIR</B>
|
||
This environment variable specifies the list of directories that
|
||
may contain the configuration file. Under UNIX, the directories
|
||
are separated by a colon (`:'), under OS/2, they are separated
|
||
by a semi-colon (`;'). If this variable is not set, the config‐
|
||
uration file is searched in two default directories: first, the
|
||
current working directory (".") and then in
|
||
/usr/local/etc/sane.d. If the value of the environment variable
|
||
ends with the directory separator character, then the default
|
||
directories are searched after the explicitly specified directo‐
|
||
ries. For example, setting <B>SANE_CONFIG_DIR</B> to "/tmp/config:"
|
||
would result in directories "tmp/config", ".", and
|
||
"/usr/local/etc/sane.d" being searched (in this order).
|
||
|
||
<B>SANE_DEBUG_HP</B>
|
||
If the library was compiled with debug support enabled, this
|
||
environment variable controls the debug level for this backend.
|
||
E.g., a value of 128 requests all debug output to be printed.
|
||
Smaller levels reduce verbosity.
|
||
|
||
<B>SANE_HOME_HP</B>
|
||
Only used for OS/2 and along with use of HP PhotoSmart Photo‐
|
||
Scanner. Must be set to the directory where the directory .sane
|
||
is located. Is used to save and read the calibration file.
|
||
|
||
<B>SANE_HP_KEEPOPEN_SCSI</B>
|
||
|
||
<B>SANE_HP_KEEPOPEN_USB</B>
|
||
|
||
<B>SANE_HP_KEEPOPEN_DEVICE</B>
|
||
For each type of connection (connect-scsi, connect-usb, con‐
|
||
nect-device) it can be specified if the connection to the device
|
||
should be kept open ("1") or not ("0"). Usually the connections
|
||
are closed after an operation is performed. Keeping connection
|
||
open to SCSI-devices can result in errors during device IO when
|
||
the scanner has not been used for some time. By default, USB-
|
||
connections are kept open. Other connections are closed.
|
||
|
||
<B>SANE_HP_RDREDO</B>
|
||
Specifies number of retries for read operation before returning
|
||
an EOF error. Only supported for non-SCSI devices. Default: 1
|
||
retry. Time between retries is 0.1 seconds.
|
||
|
||
|
||
</PRE>
|
||
<H2>BUGS</H2><PRE>
|
||
<B>HP</B> <B>PhotoSmart</B> <B>PhotoScanner</B>
|
||
In media mode 'slide' and 'negative', scan resolutions are
|
||
rounded to multiple of 300 dpi. The scanner does not scale the
|
||
data correctly on other resolutions. Some newer models (firmware
|
||
code R030 and later) do not support adjustment of con‐
|
||
trast/intensity level and tone map. The backend will simulate
|
||
this by software, but only for gray and 24 bit color.
|
||
|
||
<B>Automatic</B> <B>Document</B> <B>Feeder</B> <B>(ADF)</B>
|
||
For use of the ADF with <B><A HREF="xscanimage.1.html">xscanimage(1)</A></B>, first place paper in the
|
||
ADF and then change option scan source to 'ADF'. Press 'change
|
||
document' to load a sheet. Then press 'scan' to start a scan.
|
||
Maybe it is sufficient to press 'scan' without 'change document'
|
||
for repeated scans. The use of the preview window is not recom‐
|
||
mended when working with the ADF. Setting a window to scan from
|
||
ADF is not supported with <B><A HREF="xscanimage.1.html">xscanimage(1)</A></B>. Try <B><A HREF="xsane.1.html">xsane(1)</A></B>.
|
||
|
||
<B>Immediate</B> <B>actions</B>
|
||
Some actions in <B><A HREF="xscanimage.1.html">xscanimage(1)</A></B> (i.e. unload, select media, cali‐
|
||
brate) have an immediate effect on the scanner without starting
|
||
a scan. These options can not be used with scanimage.
|
||
|
||
|
||
</PRE>
|
||
<H2>TODO</H2><PRE>
|
||
<B>HP</B> <B>PhotoSmart</B> <B>PhotoScanner</B>
|
||
PhotoScanners with firmware release R030 and up have no firmware
|
||
support for contrast/brightness/gamma table. In the current
|
||
backend this is simulated by software on 24 bits data. Simula‐
|
||
tion on 30 bits should give better results.
|
||
|
||
<B>Data</B> <B>widths</B> <B>greater</B> <B>than</B> <B>8</B> <B>bits</B>
|
||
Custom gamma table does not work.
|
||
|
||
<B>Parallel</B> <B>scanner</B> <B>support</B>
|
||
Beside the ScanJet Plus which came with its own parallel inter‐
|
||
face card, currently only the HP ScanJet 5100C/5200C are sup‐
|
||
ported. These scanners are using an internal parallel-to-SCSI
|
||
converter which is supported by the ppSCSI-driver (see above).
|
||
|
||
|
||
</PRE>
|
||
<H2>SEE ALSO</H2><PRE>
|
||
<B><A HREF="sane.7.html">sane(7)</A></B>, <B><A HREF="sane-scsi.5.html">sane-scsi(5)</A></B>, <B><A HREF="sane-usb.5.html">sane-usb(5)</A></B>
|
||
|
||
|
||
</PRE>
|
||
<H2>AUTHOR</H2><PRE>
|
||
The sane-hp backend was written by Geoffrey T. Dairiki. HP PhotoSmart
|
||
PhotoScanner support by Peter Kirchgessner.
|
||
|
||
13 Jul 2008 <B><A HREF="sane-hp.5.html">sane-hp(5)</A></B>
|
||
</PRE>
|
||
<HR>
|
||
<ADDRESS>
|
||
Man(1) output converted with
|
||
<a href="http://www.oac.uci.edu/indiv/ehood/man2html.html">man2html</a>
|
||
</ADDRESS>
|
||
</BODY>
|
||
</HTML>
|