sane-project-website/man/sane-coolscan2.5.html

205 wiersze
9.1 KiB
HTML
Czysty Wina Historia

This file contains ambiguous Unicode characters!

This file contains ambiguous Unicode characters that may be confused with others in your current locale. If your use case is intentional and legitimate, you can safely ignore this warning. Use the Escape button to highlight these characters.

<HTML>
<HEAD>
<TITLE>sane-coolscan2.5</TITLE>
</HEAD>
<BODY BGCOLOR=#FFFFFF TEXT=#000000><H1 ALIGN=CENTER><IMG SRC="/images/sane.png" HEIGHT=117 WIDTH=346></H1>
<H1>sane-coolscan2.5</H1>
<HR>
<PRE>
<!-- Manpage converted by man2html 3.0.1 -->
<B><A HREF="sane-coolscan2.5.html">sane-coolscan2(5)</A></B> SANE Scanner Access Now Easy <B><A HREF="sane-coolscan2.5.html">sane-coolscan2(5)</A></B>
</PRE>
<H2>NAME</H2><PRE>
sane-coolscan2 - SANE backend for Nikon Coolscan film scanners
</PRE>
<H2>DESCRIPTION</H2><PRE>
The <B>sane-coolscan2</B> library implements a SANE (Scanner Access Now Easy)
backend that provides access to Nikon Coolscan film scanners. Some
functions of this backend should be considered <B>beta-quality</B> software.
Most functions have been stable for a long time, but of course new
development can not and will not function properly from the very first
day. Please report any strange behaviour to the maintainer of the back
end.
At present, the following scanners are known to work with this backend:
Model: Connection Type
--------------------------- -------------------
LS-30 (Coolscan III) SCSI
LS-2000 SCSI
LS-40 ED (Coolscan IV) USB
LS-4000 ED IEEE 1394
LS-8000 ED IEEE 1394
Please send mail to the backend author (andras@users.sourceforge.net)
to report successes or failures.
</PRE>
<H2>OPTIONS</H2><PRE>
The options the backend supports can either be selected through command
line options to programs like scanimage or through GUI elements in
xscanimage or xsane.
Valid command line options and their syntax can be listed by using
scanimage --help -d coolscan2:&lt;interface&gt;:&lt;device&gt;
where &lt;interface&gt; and &lt;device&gt; specify the device in question, as in
the configuration file (see next section). The -d parameter and its
argument can be omitted to obtain information on the first scanner
identified. Use the command
scanimage -L
to list all devices recognized by your SANE installation.
The options should be fully described by the description or tooltips
given by frontend. Here is a description of some of the most important
options, in the syntax with which they must be supplied to scanimage:
<I>--frame</I> <I>&lt;n&gt;</I>
This option specifies which frame to operate on, if a motorized
film strip feeder or APS adapter are used. The frame number <I>&lt;n&gt;</I>
ranges from 1 to the number of frames available, which is sensed
each time the backend is initialized (usually each time you
start the frontend).
<I>--subframe</I> <I>&lt;x&gt;</I>
This option shifts the scan window by the specified amount
(default unit is mm).
<I>--infrared=yes/no</I>
If set to "yes", the scanner will read the infrared channel,
thus allowing defect removal in software. The infrared image is
read during a second scan, with no options altered. The backend
must not be restarted between the scans. If you use scanimage,
perform a batch scan with batch-count=2 to obtain the IR infor
mation.
<I>--depth</I> <I>&lt;n&gt;</I>
Here &lt;n&gt; can either be 8 or the maximum number of bits supported
by the scanner (10, 12, or 14). It specifies whether or not the
scanner reduces the scanned data to 8 bits before sending it to
the backend. If 8 bits are used, some information and thus image
quality is lost, but the amount of data is smaller compared to
higher depths. Also, many imaging programs and image formats
cannot handle depths greater than 8 bits.
<I>--autofocus</I>
Perform autofocus operation. Unless otherwise specified by the
other options ( <I>--focus-on-centre</I> and friends), focusing is per
formed on the centre of the selected scan area.
<I>--ae-wb</I>
<I>--ae</I> Perform a pre-scan to calculate exposure values automatically.
<I>--ae-wb</I> will maintain the white balance, while <I>--ae</I> will adjust
each channel separately.
<I>--exposure</I>
Multiply all exposure times with this value. This allows expo
sure correction without modifying white balance.
<I>--load</I> Load the next slide when using the slide loader.
<I>--eject</I>
Eject the film strip or mounted slide when using the slide
loader.
<I>--reset</I>
Reset scanner. The scanner will perform the same action as when
power is turned on: it will eject the film strip and calibrate
itself. Use this whenever the scanner refuses to load a film
strip properly, as a result of which <I>--eject</I> does not work.
</PRE>
<H2>CONFIGURATION FILE</H2><PRE>
The configuration file /usr/local/etc/sane.d/coolscan2.conf specifies
the device(s) that the backend will use. Owing to the nature of the
supported connection types SCSI, USB, and IEEE 1394, the default con
figuration file supplied with the SANE distribution should work without
being edited.
Each line in the configuration file is either of the following, where
all entries are case-sensitive:
<I>blank</I> <I>or</I> <I>starting</I> <I>with</I> <I>a</I> <I>'#'</I> <I>character</I>
These lines are ignored, thus '#' can be used to include com
ments.
<I>containing</I> <I>only</I> <I>the</I> <I>word</I> <I>"auto"</I>
This instructs the backend to probe for a scanner by scanning
the buses for devices with know identifiers. This is the action
taken when no configuration file is present.
<I>a</I> <I>line</I> <I>of</I> <I>the</I> <I>form</I> <I>&lt;interface&gt;:&lt;device&gt;</I>
Here &lt;interface&gt; can be one of "scsi" or "usb", and &lt;device&gt; is
the device file of the scanner. Note that IEEE 1394 devices are
handled by the SBP-2 module in the kernel and appear to SANE as
SCSI devices.
</PRE>
<H2>FILES</H2><PRE>
<I>/usr/local/lib/sane/libsane-coolscan2.a</I>
The static library implementing this backend.
<I>/usr/local/lib/sane/libsane-coolscan2.so</I>
The shared library implementing this backend (present on systems
that support dynamic loading).
<I>/usr/local/etc/sane.d/coolscan2.conf</I>
Configuration file for this backend, read each time the backend
is initialized.
</PRE>
<H2>ENVIRONMENT</H2><PRE>
<B>SANE_DEBUG_COOLSCAN2</B>
If the library was compiled with debug support enabled, this
environment variable controls the debug level for this backend.
E.g., a value of 128 requests all debug output to be printed.
Smaller levels reduce verbosity.
</PRE>
<H2>SEE ALSO</H2><PRE>
<B><A HREF="sane-scsi.5.html">sane-scsi(5)</A></B>, <B><A HREF="sane-usb.5.html">sane-usb(5)</A></B>, <B><A HREF="scanimage.1.html">scanimage(1)</A></B>, <B><A HREF="xscanimage.1.html">xscanimage(1)</A></B>, <B><A HREF="xsane.1.html">xsane(1)</A></B>
</PRE>
<H2>BUGS</H2><PRE>
Currently, the SANE protocol does not allow automatically updating
options whenever the hardware changes. Thus the number of choices for
the <B>--frame</B> option will be fixed when the backend is initialized (usu
ally when the user runs the frontend). In particular, if there is no
film strip in the automatic film strip feeder when the backend is ini
tialized, the frame option will not appear at all. Also, restarting the
frontend after swapping film adapters is strongly recommended.
Linux kernels prior to 2.4.19 had a patch that truncated INQUIRY data
from IEEE 1394 scanners to 36 bytes, discarding vital information about
the scanner. The IEEE 1394 models therefore only work with 2.4.19 or
later.
No real bugs currently known, please report any to the backend main
tainer or the SANE developers' email list.
</PRE>
<H2>AUTHORS</H2><PRE>
The backend is written and maintained by András Major
(andras@users.sourceforge.net).
11 Jul 2008 <B><A HREF="sane-coolscan2.5.html">sane-coolscan2(5)</A></B>
</PRE>
<HR>
<ADDRESS>
Man(1) output converted with
<a href="http://www.oac.uci.edu/indiv/ehood/man2html.html">man2html</a>
</ADDRESS>
</BODY>
</HTML>