<H2>NAME</H2><PRE>
|
|
sane-sm3600 - SANE backend for Microtek scanners with M011 USB chip
|
|
|
|
|
|
</PRE>
|
|
<H2>DESCRIPTION</H2><PRE>
|
|
The <B>sane-sm3600</B> library implements a SANE (Scanner Access Now Easy)
|
|
backend that provides access to some Microtek scanners with the Toshiba
|
|
M011 custom USB chip. This backend should be considered alpha.
|
|
|
|
There are also backends for Microtek scanners with SCSI command set.
|
|
Refer to <B><A HREF="sane-microtek.5.html">sane-microtek(5)</A></B> and <B><A HREF="sane-microtek2.5.html">sane-microtek2(5)</A></B> for details.
|
|
|
|
At present, the following scanners are known positively to work with
|
|
this backend:
|
|
|
|
Vendor Product id: Remark:
|
|
-------- -------------- -----------
|
|
Microtek ScanMaker 3600 all modes ok
|
|
Microtek ScanMaker 3700 reported to work
|
|
Microtek ScanMaker 3750 reported to work
|
|
|
|
If you own a Microtek scanner with the M011 chip other than the ones
|
|
listed above, it may or may not work with SANE!
|
|
|
|
|
|
</PRE>
|
|
<H2>FRONTEND OPTIONS</H2><PRE>
|
|
This backend dynamically enables the options for the frontend, that are
|
|
supported by the scanner in dependence of the scanning-mode and other
|
|
options. Not supported options are disabled.
|
|
|
|
The following options are supported by the Microtek2-driver:
|
|
|
|
Color, grayscale, halftone and lineart scans.
|
|
|
|
contrast, brightness, control, gamma correction.
|
|
|
|
|
|
</PRE>
|
|
<H2>DEVICE NAMES</H2><PRE>
|
|
This backend does not support device names in a standardized form.
|
|
|
|
|
|
</PRE>
|
|
<H2>CONFIGURATION</H2><PRE>
|
|
This backend does not support a configuration file right now.
|
|
|
|
|
|
</PRE>
|
|
<H2>FILES</H2><PRE>
|
|
<I>/usr/local/lib/sane/libsane-sm3600.a</I>
|
|
The static library implementing this backend.
|
|
|
|
<I>/usr/local/lib/sane/libsane-sm3600.so</I>
|
|
The shared library implementing this backend (present on systems
|
|
that support dynamic loading).
|
|
|
|
|
|
</PRE>
|
|
<H2>ENVIRONMENT</H2><PRE>
|
|
<B>SANE_DEBUG_SM3600</B>
|
|
If the library was compiled with debug support enabled, this
|
|
environment variable controls the debug level for this backend.
|
|
E.g., a value of 128 requests all debug output to be printed.
|
|
Smaller levels reduce verbosity. To see error messages on stderr
|
|
set SANE_DEBUG_SM3600 to 1.
|
|
|
|
E.g. just say:
|
|
export SANE_DEBUG_SM3600=5
|
|
|
|
|
|
</PRE>
|
|
<H2>SEE ALSO</H2><PRE>
|
|
<B><A HREF="sane-microtek2.5.html">sane-microtek2(5)</A></B>, http://sm3600.sourceforge.net
|
|
|
|
|
|
</PRE>
|
|
<H2>AUTHOR</H2><PRE>
|
|
Marian Eichholz (eichholz@computer.org)
|
|
Glenn Ramsey (glenn@componic.com)
|
|
|
|
sane-backends 1.0.18 16 August 2005 <B><A HREF="sane-sm3600.5.html">sane-sm3600(5)</A></B>
|
|