sane-project-website/unsupported/hp-scanjet-4600.html

343 wiersze
12 KiB
HTML

<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN">
<html>
<head>
<title>Scanner information</title>
<meta http-equiv="Content-Type" content="text/html; charset=iso-8859-1">
<meta name="author" content="Henning Meier-Geinitz">
<meta name="keywords" content="sane, backend, driver, scanner, unsupported">
<link href="mailto:henning@meier-geinitz.de" rev="made">
<link rel="icon" href="/favicon.ico" type="image/x-icon">
<link rel="shortcut icon" href="/favicon.ico" type="image/x-icon">
</head>
<body>
<h1>Scanners not supported by SANE</h1>
<h2>Manufacturer and model</h2>
<p>
Hewlett-Packard Scanjet 4600<br>
Hewlett-Packard Scanjet 4670<br>
</p>
<h2>Bus type</h2>
<p>
USB
</p>
<h2>Vendor ID</h2>
<p>
0x03f0
</p>
<h2>Product ID</h2>
<p>
0x3005
</p>
<h2>Chipset</h2>
<p>
The board contains the following <a
href="http://www.hernk.com/hp_scanjet_4600.jpg">chips</a>: HY57V161610 1M
* 16 RAM, A3967SLB motor driver, "HP 163-74-000002" main chip, made by SQ
(Service and Quality).
</p>
<h2>Comments</h2>
<p>
bxerroz at gmail.com writes: ">s of today 12-04-2005(04/12/2005) i have
created NUMEROUS log files for the scanner itself, including Preview
Scans, scans at resolutions 200dpi, 1200dpi, 9600dpi, in black and white,
and in millions of colors. scaned at sizes, 1x1cm, 13x13cm, and
21.61x29.72cm (scanner max). while i have no place to post, i have an
archived file with all of them and can be sent out if desired. i will
attempt my best on my doing my own reserch into the driver, but i am
vastly lacking in the experience todo so. please email me with any
questions or comments, and as i said, i can send the archive at will (its
only about 300kb packed, a few megs unpacked)
</p>
<p>
About the 4670: "The scanner works on Mac OS X (10.3) with HP's supplied
software, and so does Adobe Photoshop Elements (with a HP supplied
plug-in), but Apple's "Image Capture" does not see it." Another owner of
this scanner writes: "Upright scanner, heard it was almost identical to
4660."
</p>
<p>
The 4670 is the same as the 4600 but has an additional transparency
adapter.
</p>
<p>
In this <a href="http://lists.alioth.debian.org/pipermail/sane-devel/2007-October/020138.html">message</a>
on sane-devel, Alexander Bechikov announced he has collected <a href="http://hp46xx.narod.ru/">logs</a>
for this scanner.
</p>
<h2>Output of /proc/bus/usb/devices or sane-find-scanner -v -v</h2>
<pre>
4600:
T: Bus=04 Lev=01 Prnt=01 Port=02 Cnt=01 Dev#= 2 Spd=480 MxCh= 0
D: Ver= 2.00 Cls=00(&gt;ifc ) Sub=00 Prot=00 MxPS=64 #Cfgs= 1
P: Vendor=03f0 ProdID=3005 Rev= 1.00
S: Manufacturer=Hewlett-Packard.
S: Product=hp scanjet
S: SerialNumber=CN3B4B502993
C:* #Ifs= 1 Cfg#= 1 Atr=c0 MxPwr=100mA
I: If#= 0 Alt= 0 #EPs= 3 Cls=ff(vend.) Sub=ff Prot=ff Driver=(none)
E: Ad=01(O) Atr=02(Bulk) MxPS= 512 Ivl=0ms
E: Ad=82(I) Atr=02(Bulk) MxPS= 512 Ivl=0ms
E: Ad=83(I) Atr=03(Int.) MxPS= 1 Ivl=500us
&lt;device descriptor of 0x03f0/0x3005 at 005:002 (Hewlett-Packard. hp scanjet )&gt;
bLength 18
bDescriptorType 1
bcdUSB 2.00
bDeviceClass 0
bDeviceSubClass 0
bDeviceProtocol 0
bMaxPacketSize0 64
idVendor 0x03F0
idProduct 0x3005
bcdDevice 1.00
iManufacturer 1 (Hewlett-Packard. )
iProduct 2 (hp scanjet )
iSerialNumber 3 (CN3AKB565593)
bNumConfigurations 1
&lt;configuration 0&gt;
bLength 9
bDescriptorType 2
wTotalLength 39
bNumInterfaces 1
bConfigurationValue 1
iConfiguration 0 ()
bmAttributes 192 (Self-powered)
MaxPower 100 mA
&lt;interface 0&gt;
&lt;altsetting 0&gt;
bLength 9
bDescriptorType 4
bInterfaceNumber 0
bAlternateSetting 0
bNumEndpoints 3
bInterfaceClass 255
bInterfaceSubClass 255
bInterfaceProtocol 255
iInterface 0 ()
&lt;endpoint 0&gt;
bLength 7
bDescriptorType 5
bEndpointAddress 0x01 (out 0x01)
bmAttributes 2 (bulk)
wMaxPacketSize 64
bInterval 0 ms
bRefresh 0
bSynchAddress 0
&lt;endpoint 1&gt;
bLength 7
bDescriptorType 5
bEndpointAddress 0x82 (in 0x02)
bmAttributes 2 (bulk)
wMaxPacketSize 64
bInterval 0 ms
bRefresh 0
bSynchAddress 0
&lt;endpoint 2&gt;
bLength 7
bDescriptorType 5
bEndpointAddress 0x83 (in 0x03)
bmAttributes 3 (interrupt)
wMaxPacketSize 1
bInterval 3 ms
bRefresh 0
bSynchAddress 0
&lt;trying to find out which USB chip is used&gt;
checking for GT-6801 ...
this is not a GT-6801 (bDeviceClass = 0)
checking for GT-6816 ...
this is not a GT-6816 (bcdUSB = 0x200)
checking for MA-1017 ...
this is not a MA-1017 (bDeviceClass = 0, bInterfaceClass = 255)
checking for MA-1015 ...
this is not a MA-1015 (bDeviceClass = 0)
checking for MA-1509 ...
this is not a MA-1509 (bDeviceClass = 0)
checking for LM983[1,2,3] ...
this is not a LM983x (bcdUSB = 0x200)
checking for GL646 ...
this is not a GL646 (bDeviceClass = 0, bInterfaceClass = 255)
checking for GL646_HP ...
this is not a GL646_HP (bDeviceClass = 0, bInterfaceClass = 255)
checking for GL660+GL646 ...
this is not a GL660+GL646 (bDeviceClass = 0, bInterfaceClass = 255)
checking for GL841 ...
this is not a GL841 (bDeviceClass = 0, bInterfaceClass = 255)
checking for ICM532B ...
check 1, this is not a ICM532B (bDeviceClass = 0, bInterfaceClass = 255)
&lt;Couldn't determine the type of the USB chip&gt;
found USB scanner (vendor=0x03f0 [Hewlett-Packard. ], product=0x3005 [hpscanjet ]) at libusb:005:002
4670:
T: Bus=03 Lev=01 Prnt=01 Port=01 Cnt=01 Dev#= 5 Spd=480 MxCh= 0
D: Ver= 2.00 Cls=00(&gt;ifc ) Sub=00 Prot=00 MxPS=64 #Cfgs= 1
P: Vendor=03f0 ProdID=3005 Rev= 1.00
S: Manufacturer=Hewlett-Packard.
S: Product=hp scanjet
S: SerialNumber=CN416C298794
C:* #Ifs= 1 Cfg#= 1 Atr=c0 MxPwr=100mA
I: If#= 0 Alt= 0 #EPs= 3 Cls=ff(vend.) Sub=ff Prot=ff Driver=(none)
E: Ad=01(O) Atr=02(Bulk) MxPS= 512 Ivl=0ms
E: Ad=82(I) Atr=02(Bulk) MxPS= 512 Ivl=0ms
E: Ad=83(I) Atr=03(Int.) MxPS= 1 Ivl=500us
&lt;device descriptor of 0x03f0/0x3005 at 003:005 (Hewlett-Packard. hp scanjet )&gt;
bLength 18
bDescriptorType 1
bcdUSB 2.00
bDeviceClass 0
bDeviceSubClass 0
bDeviceProtocol 0
bMaxPacketSize0 64
idVendor 0x03F0
idProduct 0x3005
bcdDevice 1.00
iManufacturer 1 (Hewlett-Packard. )
iProduct 2 (hp scanjet )
iSerialNumber 3 (CN416C298794)
bNumConfigurations 1
&lt;configuration 0&gt;
bLength 9
bDescriptorType 2
wTotalLength 39
bNumInterfaces 1
bConfigurationValue 1
iConfiguration 0 ()
bmAttributes 192 (Self-powered)
MaxPower 100 mA
&lt;interface 0&gt;
&lt;altsetting 0&gt;
bLength 9
bDescriptorType 4
bInterfaceNumber 0
bAlternateSetting 0
bNumEndpoints 3
bInterfaceClass 255
bInterfaceSubClass 255
bInterfaceProtocol 255
iInterface 0 ()
&lt;endpoint 0&gt;
bLength 7
bDescriptorType 5
bEndpointAddress 0x01 (out 0x01)
bmAttributes 2 (bulk)
wMaxPacketSize 512
bInterval 0 ms
bRefresh 0
bSynchAddress 0
&lt;endpoint 1&gt;
bLength 7
bDescriptorType 5
bEndpointAddress 0x82 (in 0x02)
bmAttributes 2 (bulk)
wMaxPacketSize 512
bInterval 0 ms
bRefresh 0
bSynchAddress 0
&lt;endpoint 2&gt;
bLength 7
bDescriptorType 5
bEndpointAddress 0x83 (in 0x03)
bmAttributes 3 (interrupt)
wMaxPacketSize 1
bInterval 3 ms
bRefresh 0
bSynchAddress 0
&lt;trying to find out which USB chip is used&gt;
checking for GT-6801 ...
this is not a GT-6801 (bDeviceClass = 0)
checking for GT-6816 ...
this is not a GT-6816 (bcdUSB = 0x200)
checking for GT-8911 ...
this is not a GT-8911 (check 2, bcdUSB = 0x200)
checking for MA-1017 ...
this is not a MA-1017 (bDeviceClass = 0, bInterfaceClass = 255)
checking for MA-1015 ...
this is not a MA-1015 (bDeviceClass = 0)
checking for MA-1509 ...
this is not a MA-1509 (bDeviceClass = 0)
checking for LM983[1,2,3] ...
this is not a LM983x (bcdUSB = 0x200)
checking for GL646 ...
this is not a GL646 (bDeviceClass = 0, bInterfaceClass = 255)
checking for GL646_HP ...
this is not a GL646_HP (bDeviceClass = 0, bInterfaceClass = 255)
checking for GL660+GL646 ...
this is not a GL660+GL646 (bDeviceClass = 0, bInterfaceClass = 255)
checking for GL841 ...
this is not a GL841 (bDeviceClass = 0, bInterfaceClass = 255)
checking for ICM532B ...
this is not a ICM532B (check 1, bDeviceClass = 0, bInterfaceClass = 255)
checking for PV8630/LM9830 ...
this is not a PV8630/LM9830 (bcdUSB = 0x200)
checking for M011 ...
this is not a M011 (bDeviceClass = 0)
checking for RTS8822L-01H ...
this is not a RTS8822L-01H (bEndpointAddress = 0x1, bmAttributes = 0x2, wMaxPacketSize = 0x200, bInterval = 0x0)
checking for rts8858c ...
this is not a rts8858c (bcdUSB = 0x200)
checking for SQ113 ...
&lt;This USB chip looks like a SQ113&gt;
found USB scanner (vendor=0x03f0 [Hewlett-Packard. ], product=0x3005 [hp scanjet ], chip=SQ113) at libusb:003:005
</pre>
<h1>Want to add or correct information?</h1>
<p>
If anything is wrong or missing on this page please <a href="/bugs.html">file a bug report</a>
or use the <a href="http://www.meier-geinitz.de:80/tinc?key=rDoQ7lrj&#38;formname=adddev" target="_top">the
form for adding an unsupported device</a>.
</p>
<p>
If you own an unsupported scanner, please send as much information as
possible. Especially the output of <em>sane-find-scanner -v -v</em>
and/or <em>cat /proc/scsi/scsi</em> (for SCSI scanners) or <em>cat
/proc/bus/usb/devices</em> (for USB scanners) can help. If you dare to
open the scanner, have a look at the text that's printed on the
chips. That may help to identify the chipset. If you know that the
scanner is similar to another one (e.g. supported by the same Windows
driver), please also mention this fact.
</p>
<h1><a href="/manufacturers.html">Information for Manufacturers</a></h1>
<p>
Are you a manufacturer or vendor of scanners and one of your scanners is
not supported by SANE yet? In this case please have a look at our <a
href="/manufacturers.html">information for manufacturers</a>.
</p>
<h1>Links</h1>
<ul>
<li>
General information on how to <a href="/contrib.html">contribute to SANE</a>, e.g. by writing
backends
</li>
<li>
<a
href="/cgi-bin/driver.pl">Scanner
search engine</a>
</li>
<li>
<a href="http://www.sane-project.org/">SANE homepage</a>
</li>
</ul>
<hr>
<p>
<a href="/">SANE homepage</a><br>
<a href="/imprint.html">Contact</a>
</p>
<p>
<font size="-1">$Date$ $Author$</font>
</p>
</body>
</html>