<H2>NAME</H2><PRE>
|
||
sane-umax_pp - SANE backend for Umax Astra parallel port flatbed scan-
|
||
ners
|
||
|
||
|
||
</PRE>
|
||
<H2>DESCRIPTION</H2><PRE>
|
||
The <B>sane-umax_pp</B> library implements a SANE (Scanner Access Now Easy)
|
||
backend that provides access to Umax parallel port flatbed scanners.
|
||
The following scanners work with this backend:
|
||
|
||
Model:
|
||
--------------------
|
||
Astra 1220P
|
||
HP3200C
|
||
Astra 1600P
|
||
Astra 2000P
|
||
|
||
This backend handles 75x75, 150x150, 300x300, 600x600 and 600x1200 dpi
|
||
scan resolutions, in color and gray levels. There is a software lineart
|
||
mode.
|
||
|
||
These scanners share the same ASIC. Only parts such as CCD and ADC
|
||
change from one to another. They even all reports being UMAX Astra
|
||
1220P via IEEE1284. There isn't software way to recognize them prop-
|
||
erly. Under windows, model is set by the driver installed, regardless
|
||
of the hardware.
|
||
|
||
<B>EPP</B> <B>MODE</B> <B>ONLY</B>
|
||
The current version of the backend use only EPP mode to communi-
|
||
cate with the scanner. PS/2 and SPP mode aren't implemented. It
|
||
is recommended that you set your parallel port to EPP in BIOS
|
||
with the current version of this backend. ECPEPP will only work
|
||
if you use a 2.4 kernel with ppdev character device support.
|
||
|
||
This backend does support parport sharing only <I>if</I> <I>you</I> <I>have</I> <I>a</I> <I>kernel</I>
|
||
<I>with</I> <I>ppdev</I> <I>support.</I>
|
||
|
||
Note that if you don't use the ppdev character device, the backend
|
||
needs to run as root. To allow user access to the scanner run the back-
|
||
end through the network interface (See <B><A HREF="saned.1.html">saned(1)</A></B> and <B><A HREF="sane-net.5.html">sane-net(5)</A></B>). A
|
||
more relaxed solution (security wise) is to add suid bit to the fron-
|
||
tend (See <B><A HREF="chmod.1.html">chmod(1)</A></B>). The backend drop root priviledges as soon as it
|
||
can, right after gaining direct access to IO ports, which lessen risks
|
||
when being root.
|
||
|
||
|
||
</PRE>
|
||
<H2>DEVICE NAMES</H2><PRE>
|
||
This backend expects device names of the form:
|
||
|
||
<I>port</I> <I>value</I>
|
||
|
||
Where <B>value</B> is the base address, or the ppdev device name of the port
|
||
your scanner is attached to. Known ports are <B>0x378</B>, <B>0x278</B> and <B>0x3BC</B> .
|
||
Or the name of the parallel port character device user interface, such
|
||
as /dev/parport0 for the linux ppdev, or /dev/ppi0 for FreeBSD ppi.
|
||
Under linux, if you are not sure which port your scanner is connected
|
||
to, may have a look at your /etc/modules.conf. Also typing dmesg|grep
|
||
parport in a command shell should show you a line like:
|
||
parport0: PC-style at 0x378 (0x778), irq 7, dma 3 [PCSPP,TRISTATE,COM-
|
||
PAT,ECP,DMA]
|
||
telling you about port address and mode.
|
||
|
||
If you are using the linux ppdev character device, you will have to
|
||
specify the device name, which is /dev/parport0 for the first parallel
|
||
port. Check the permissions on /dev/paraport0, many linux distributions
|
||
restrict them for root only access. Get sure they are like:
|
||
crw-rw-rw- 1 root root 99, 0 mai 20 2002 /dev/parport0
|
||
crw-rw-rw- 1 root root 99, 1 mai 20 2002 /dev/parport1
|
||
crw-rw-rw- 1 root root 99, 2 mai 20 2002 /dev/parport2
|
||
crw-rw-rw- 1 root root 99, 3 mai 20 2002 /dev/parport3
|
||
The same apply with the /dev/ppi0 character device under FreeBSD.
|
||
|
||
You can rename any device using the
|
||
|
||
<I>name</I> <I>devname</I>
|
||
<I>model</I> <I>model</I>
|
||
<I>vendor</I> <I>vendor</I>
|
||
|
||
options. These options apply to the last port option.
|
||
|
||
|
||
</PRE>
|
||
<H2>CONFIGURATION</H2><PRE>
|
||
Please make sure to edit umax_pp.conf <B>before</B> you use the backend.
|
||
|
||
The contents of the <B>umax_pp.conf</B> file is a list of options and device
|
||
names that correspond to Umax scanners. Empty lines and lines starting
|
||
with a hash mark (#) are ignored.
|
||
|
||
The height options supported are <B>red-brightness</B>, <B>green-brightness</B>,
|
||
<B>blue-brightness</B>, <B>red-contrast</B>, <B>green-contrast</B>, <B>blue-contrast</B>, <B>astra</B>,
|
||
and <B>buffer</B>.
|
||
|
||
Options <B>red-brightness</B> , <B>green-brightness</B> and <B>blue-brightness</B> allow you
|
||
to adjust the sensitivy of your scanner for the given color. Values
|
||
range from 0 (lowest brightness) to 15 (highest). If the advanced
|
||
option "Brightness" isn't checked in the frontend, the backend does
|
||
automatic brightness calibration, and do not use user provided values.
|
||
|
||
Options <B>red-contrast</B> , <B>green-contrast</B> and <B>blue-contrast</B> allow you to
|
||
adjust the contrast of your scanner for the given color. Values range
|
||
from 0 (lowest contrast) to 15 (highest).
|
||
|
||
Option <B>astra</B> allows you to change the model of your scanner. Current
|
||
auto detection is based on side effects on scanning when using 1220P
|
||
command set on other models, so it may fail on unkown hardware combina-
|
||
tion. Valid values are 1220, 1600 and 2000. It is usefull only when
|
||
autodetection fails to detect properly your scanner model. If your
|
||
scanner work properly but is reported wrongly, let it be that way. The
|
||
only valid case to change the model is when your scanner produces
|
||
'black' or
|
||
'inverted' scans. In this case you can put the model. Be aware that
|
||
it will prevent autodetection.
|
||
|
||
Option <B>buffer</B> allows you to change the size of the scan buffer. The
|
||
size must be specified in bytes. The default value is 2 megabytes.
|
||
Decreasing this value will improve the progress status reporting in the
|
||
frontend, but will stall the scan more often.
|
||
|
||
|
||
</PRE>
|
||
<H2>FILES</H2><PRE>
|
||
<I>/usr/local/etc/sane.d/umax</I><B>_</B><I>pp.conf</I>
|
||
The backend configuration file (see also description of
|
||
<B>SANE_CONFIG_DIR</B> below).
|
||
|
||
<I>/usr/local/lib/sane/libsane-umax</I><B>_</B><I>pp.a</I>
|
||
The static library implementing this backend.
|
||
|
||
<I>/usr/local/lib/sane/libsane-umax</I><B>_</B><I>pp.so</I>
|
||
The shared library implementing this backend (present on systems
|
||
that support dynamic loading).
|
||
|
||
|
||
</PRE>
|
||
<H2>ENVIRONMENT</H2><PRE>
|
||
<B>SANE_CONFIG_DIR</B>
|
||
This environment variable specifies the list of directories that
|
||
may contain the configuration file. Under UNIX, the directories
|
||
are separated by a colon (`:'), under OS/2, they are separated
|
||
by a semi-colon (`;'). If this variable is not set, the config-
|
||
uration file is searched in two default directories: first, the
|
||
current working directory (".") and then in
|
||
/usr/local/etc/sane.d. If the value of the environment variable
|
||
ends with the directory separator character, then the default
|
||
directories are searched after the explicitly specified directo-
|
||
ries. For example, setting <B>SANE_CONFIG_DIR</B> to "/tmp/config:"
|
||
would result in directories "tmp/config", ".", and
|
||
"/usr/local/etc/sane.d" being searched (in this order).
|
||
|
||
<B>SANE_DEBUG_UMAX_PP</B>
|
||
If the library was compiled with debug support enabled, this
|
||
environment variable controls the debug level for this backend.
|
||
E.g., a value of 128 requests all debug output to be printed.
|
||
Smaller levels reduce verbosity.
|
||
|
||
level debug output
|
||
------- ------------------------------
|
||
0 nothing
|
||
1 errors
|
||
2 warnings & minor errors
|
||
3 additional information
|
||
4 debug information
|
||
5 code flow (not supported yet)
|
||
6 special debug information
|
||
|
||
<B>SANE_DEBUG_UMAX_PP_LOW</B>
|
||
This variable sets the debug level for the SANE interface for
|
||
the Umax ASIC. Note that enabling this will spam your terminal
|
||
with some million lines of debug output.
|
||
|
||
level debug output
|
||
------- -------------------------------
|
||
0 nothing
|
||
1 errors
|
||
8 command blocks
|
||
16 detailed code flow
|
||
32 dump datafiles
|
||
255 everything
|
||
|
||
|
||
</PRE>
|
||
<H2>SEE ALSO</H2><PRE>
|
||
<B><A HREF="sane.7.html">sane(7)</A></B>, <B><A HREF="sane-net.5.html">sane-net(5)</A></B>, <B><A HREF="saned.1.html">saned(1)</A></B>
|
||
|
||
|
||
For latest bug fixes and information see
|
||
<I>http://umax1220p.sourceforge.net/</I>
|
||
|
||
|
||
</PRE>
|
||
<H2>AUTHOR</H2><PRE>
|
||
St<53>phane VOLTZ <svoltz@wanadoo.fr>, man page derived from mustek_pp man
|
||
page by Jochen Eisinger <jochen.eisinger@gmx.net>
|
||
|
||
|
||
</PRE>
|
||
<H2>BUG REPORTS</H2><PRE>
|
||
If something doesn't work, please contact me. But I need some informa-
|
||
tion about your scanner to be able to help you...
|
||
|
||
<I>SANE</I> <I>version</I>
|
||
run "scanimage -V" to determine this
|
||
|
||
<I>the</I> <I>backend</I> <I>version</I> <I>and</I> <I>your</I> <I>scanner</I> <I>hardware</I>
|
||
run "SANE_DEBUG_UMAX=255 scanimage -L 2>log" as root. If you
|
||
don't get any output from the umax_pp backend, make sure a line
|
||
"umax_pp" is included into your /usr/local/etc/sane.d/dll.conf.
|
||
If your scanner isn't detected, make sure you've defined the
|
||
right port address, or the correct device in your umax_pp.conf.
|
||
|
||
<I>the</I> <I>name</I> <I>of</I> <I>your</I> <I>scanner/vendor</I>
|
||
also a worthy information. Please also include the optical reso-
|
||
lution and lamp type of your scanner, both can be found in the
|
||
manual of your scanner.
|
||
|
||
<I>any</I> <I>further</I> <I>comments</I>
|
||
if you have comments about the documentation (what could be done
|
||
better), or you think I should know something, please include
|
||
it.
|
||
|
||
sane-backends 1.0.12-cvs 16 September 2003 <B><A HREF="sane-umax_pp.5.html">sane-umax_pp(5)</A></B>
|
||
</PRE>
|
||
<HR>
|
||
<ADDRESS>
|
||
Man(1) output converted with
|
||
<a href="http://www.oac.uci.edu/indiv/ehood/man2html.html">man2html</a>
|
||
</ADDRESS>
|
||
</BODY>
|
||
</HTML>
|