kopia lustrzana https://gitlab.com/sane-project/website
128 wiersze
5.0 KiB
HTML
128 wiersze
5.0 KiB
HTML
<HTML>
|
||
<HEAD>
|
||
<TITLE>sane-dc25.5</TITLE>
|
||
</HEAD>
|
||
<BODY BGCOLOR=#FFFFFF TEXT=#000000><H1 ALIGN=CENTER><IMG SRC="../images/sane.png" HEIGHT=117 WIDTH=346></H1>
|
||
<H1>sane-dc25.5</H1>
|
||
<HR>
|
||
<PRE>
|
||
<!-- Manpage converted by man2html 3.0.1 -->
|
||
<B><A HREF="sane-dc25.5.html">sane-dc25(5)</A></B> SANE Scanner Access Now Easy <B><A HREF="sane-dc25.5.html">sane-dc25(5)</A></B>
|
||
|
||
|
||
</PRE>
|
||
<H2>NAME</H2><PRE>
|
||
sane-dc25 - SANE backend for Kodak DC20/DC25 Digital Cameras
|
||
|
||
|
||
</PRE>
|
||
<H2>DESCRIPTION</H2><PRE>
|
||
The <B>sane-dc25</B> library implements a SANE (Scanner Access Now Easy) back‐
|
||
end that provides access to Kodak DC20 and DC25 cameras. At present,
|
||
only the DC25 has been tested, but since the code is based on a DC20
|
||
interface program, it is likely to work for that model also.
|
||
|
||
|
||
</PRE>
|
||
<H2>DEVICE NAMES</H2><PRE>
|
||
The current version of the backend only allows one camera to be con‐
|
||
nected. The device name is always "0".
|
||
|
||
|
||
</PRE>
|
||
<H2>CONFIGURATION</H2><PRE>
|
||
The contents of the <I>dc25.conf</I> specify the serial port and baud rate to
|
||
use. The baud rate specifies the maximum rate to use while downloading
|
||
pictures. (The camera is always initialized using 9600 baud, then
|
||
switches to the higher rate). On my 90MHz Pentium, I usually have no
|
||
problems downloading at 115200 baud as long as the system is not exces‐
|
||
sively busy and the "interrupt-unmask flag" is set in the IDE driver
|
||
(hdparm -u1). Supported baud rates are: 9600, 19200, 38400, 57600, and
|
||
115200.
|
||
|
||
The dumpinquiry line causes some information about the camera to be
|
||
printed to stderr during startup. Note: This is not compatible with
|
||
saned, so make sure you don't have any dumpinquiry lines if you are
|
||
using saned (i.e. scanning on a remote machine using a network).
|
||
|
||
Empty lines and lines starting with a hash mark (#) are ignored. A
|
||
sample configuration file is shown below:
|
||
|
||
port=/dev/ttyS0
|
||
# this is a comment
|
||
baud=115200
|
||
dumpinquiry
|
||
|
||
|
||
</PRE>
|
||
<H2>FILES</H2><PRE>
|
||
<I>/usr/local/etc/sane.d/dc25.conf</I>
|
||
The backend configuration file (see also description of
|
||
<B>SANE_CONFIG_DIR</B> below).
|
||
|
||
<I>/usr/local/lib/sane/libsane-dc25.a</I>
|
||
The static library implementing this backend.
|
||
|
||
<I>/usr/local/lib/sane/libsane-dc25.so</I>
|
||
The shared library implementing this backend (present on systems
|
||
that support dynamic loading).
|
||
|
||
|
||
</PRE>
|
||
<H2>ENVIRONMENT</H2><PRE>
|
||
<B>SANE_CONFIG_DIR</B>
|
||
This environment variable specifies the list of directories that
|
||
may contain the configuration file. Under UNIX, the directories
|
||
are separated by a colon (`:'), under OS/2, they are separated
|
||
by a semi-colon (`;'). If this variable is not set, the config‐
|
||
uration file is searched in two default directories: first, the
|
||
current working directory (".") and then in
|
||
/usr/local/etc/sane.d. If the value of the environment variable
|
||
ends with the directory separator character, then the default
|
||
directories are searched after the explicitly specified directo‐
|
||
ries. For example, setting <B>SANE_CONFIG_DIR</B> to "/tmp/config:"
|
||
would result in directories "tmp/config", ".", and
|
||
"/usr/local/etc/sane.d" being searched (in this order).
|
||
|
||
<B>SANE_DEBUG_DC25</B>
|
||
If the library was compiled with debugging support enabled, this
|
||
environment variable controls the debug level for this backend.
|
||
A value of 128 requests maximally copious debug output; smaller
|
||
levels reduce verbosity.
|
||
|
||
|
||
</PRE>
|
||
<H2>SEE ALSO</H2><PRE>
|
||
<B><A HREF="sane.7.html">sane(7)</A></B>
|
||
|
||
|
||
</PRE>
|
||
<H2>AUTHOR</H2><PRE>
|
||
Peter Fales, dc25-devel@fales-lorenz.net
|
||
|
||
|
||
</PRE>
|
||
<H2>BUGS</H2><PRE>
|
||
Known bugs/limitations are:
|
||
|
||
I haven't figured out how to trigger an option reload following a
|
||
"scan." This causes problems when a new picture is snapped for exam‐
|
||
ple, the slider that is used to select the picture from the camera may
|
||
not be updated immediately.
|
||
|
||
More general comments, suggestions, and inquiries about frontends or
|
||
SANE should go to the SANE Developers mailing list (see
|
||
http://www.sane-project.org/mailing-lists.html for details). You must
|
||
be subscribed to the list, otherwise your mail won't be sent to the
|
||
subscribers.
|
||
|
||
11 Jul 2008 <B><A HREF="sane-dc25.5.html">sane-dc25(5)</A></B>
|
||
</PRE>
|
||
<HR>
|
||
<ADDRESS>
|
||
Man(1) output converted with
|
||
<a href="http://www.oac.uci.edu/indiv/ehood/man2html.html">man2html</a>
|
||
</ADDRESS>
|
||
</BODY>
|
||
</HTML>
|