Suggestions for changes for sane-api-2 (2002-12-24)
|
|
|
|
(x = already included into sane2.tex)
|
|
|
|
- SANE_FRAME_*:
|
|
|
|
x - SANE_FRAME_RAW, formatdesc="red:8,green:8,blue:8", replaces old SANE_FRAME_* types
|
|
|
|
x - SANE_FRAME_MIME, formatdesc=MIME-desciptor, only one frame/image, arbitary data
|
|
this allows transmission of e.g. jpeg, tiff and any other data format
|
|
|
|
x - SANE_FRAME_GRAY/RGB/RED/GREEN/BLUE only allowed for sane-1 backends.
|
|
|
|
- remove multi-frame paradigm at all?
|
|
|
|
- remove multi-channel 1 Bit mode?
|
|
|
|
- define 0 = black for all modes?
|
|
|
|
|
|
- parameter.flags
|
|
|
|
x - compatible to sane-1
|
|
|
|
x - adds more_images, new_page, front/backside info, 28 more flags available
|
|
|
|
x - dpi_x, dpi_y, proposed_filename, formatdesc, channels_per_image
|
|
|
|
(x)- 32 bytes for future extension (set to 0)
|
|
Check how to do this without creating portability nightmares.
|
|
Keep in mind that the size of SANE_Int is unknown, same is true for
|
|
SANE_String and even char.
|
|
|
|
- define the following well known options:
|
|
|
|
x - BIT_DEPTH = Word_List with bits/sample
|
|
|
|
x - GAMMA_VECTOR, and GAMMA_VECTOR_[RGB]
|
|
|
|
x - RESOLUTION or (X_RESOLUTION and Y_RESOLUTION)
|
|
|
|
x - scanmode COLOR, GRAY, LINEART (for frontend defaults, e.g. for fax => Gray)
|
|
|
|
x - scansource FLATBED/DOCUMENTFEEDER/TRANSPARENCY
|
|
|
|
x - ANALOG_GAMMA
|
|
|
|
x - HIGHLIGHT
|
|
|
|
x - SHADOW
|
|
|
|
x - THRESHOLD
|
|
|
|
x - LAMP_CONTROL
|
|
|
|
x - Scanner button options and protocol
|
|
|
|
- set focus position FOCUS_POS_X, FOCUS_POS_Y
|
|
|
|
- multi pass for film scanners
|
|
- number of passes (either native or EMULATED)
|
|
SANE_TYPE_INT, word_list or range
|
|
|
|
- direct selection of image number?
|
|
SANE_TYPE_INT
|
|
|
|
- exposure time
|
|
|
|
x - SANE_CAP_ADVANCED for a group
|
|
|
|
x - SANE_CAP_ALWAYS_SETTABLE ??? (xcam/quickcam?)
|
|
|
|
x - SANE_CAP_HIDDEN: Don't display option at all
|
|
|
|
|
|
x- add to SANE_Device
|
|
- email_backend_author (string)
|
|
- device_location (string)
|
|
- comment (string)
|
|
- reserved_string (string)
|
|
- version_code (integer)
|
|
- backend_capability_flags (integer)
|
|
- reserved_int (integer)
|
|
|
|
(x)- define recommended file formats for internationalization
|
|
in sane_i18n definition files:
|
|
*.po, default translation tables: *.(g)mo
|
|
|
|
x- sane_open does return sane_device:
|
|
A frontend may decide not to call sane_get_devices
|
|
because it already knows which device shall be
|
|
opened. In this case it does not get any information
|
|
about the device (vendor, model, ...). So it makes
|
|
sense to return the SANE_Device in sane_open
|
|
|
|
!- saned or a stand alone "turn lamp off deamon" should get
|
|
an internal timer to turn off the lamp of some scanners.
|
|
This has to be defined closer.
|
|
May be it is necessary to find out how long a scanner
|
|
has not been used. For this saned needs a function
|
|
like sane_get_offline_time()...
|
|
|
|
!- define a way how multiple scanareas can be handled
|
|
before the scanning is started:
|
|
Create well-known options to set the next tl-y
|
|
|
|
- define error codes for sane_get_parameters
|
|
|
|
x- define return value of sane_init - also necessary for SANE1
|
|
|
|
x- define bit order of 1 bit modes - also necessary for SANE1
|
|
|
|
!- implementation note for select_fd - also necessary for SANE1
|
|
|
|
!- all texts and translations: UTF-8 format
|
|
(this is used in KDE and gtk+-2.x)
|
|
may be UTF-8 should be forced as SANE_Char format.
|
|
|
|
!- download backend translation and documentation:
|
|
The Download function does not care about the file
|
|
format, this propably also has to be defined in the sane standard.
|
|
- sane_download_backend_file(filename). The backend
|
|
has to load the file from a fixed directory. The path
|
|
to the directory has to contain the backend name,
|
|
e.g: /usr/local/share/sane/sane-umax/
|
|
The frontend can not change the directory due to security!!!
|
|
|
|
!- let backend display a frontend-info or -selection (ok/cancel)
|
|
dialog-box (e.g. "Calibration in progress: wait 10/9/8/... seconds")
|
|
this has to be done with a callback, eg.:
|
|
sane_frontend_dialog_display(**window, text, ok_text, cancel_text, backend_dialog_callback_function)
|
|
sane_frontend_dialog_close(window)
|
|
the frontend function has to be implemented in a way that the backend
|
|
can change the text.
|
|
A good place to define the callback functions could be sane_init,
|
|
where already the authorization_callback is defined.
|
|
|
|
!- give backend the chance to tell the frontend while/after scan
|
|
that the options have changed (e.g. film scanner reduces
|
|
number of available images):
|
|
may be a flag (comparable to int *i in sane_control_option)
|
|
Maybe the frontend should reload the decriptors after a scan anyway?
|
|
|
|
-- add sane_get_device_info function that allows the frontend
|
|
to ask for information about all involved backends and meta backends
|
|
that are used.
|
|
is this still needed with version_code in sane_device?
|
|
|
|
-- sane_extended_call() and sane_extended_callback() ?
|
|
I don`t like this because it makes it too simple
|
|
to add proprietary functions that are not defined
|
|
in the sane standard
|
|
|
|
(x)- define what parts in a option_descriptor may be changed after
|
|
it has been set up and passed to the frontend
|
|
Maybe add size to list of members that can be changed?
|
|
Move definition to sane_get_select_fd?
|
|
|
|
?- add #define SANE_OPTION_IS_GETTABLE(cap) (((cap) & (SANE_CAP_SOFT_DETECT | SANE_CAP_INACTIVE)) == SANE_CAP_SOFT_DETECT)
|
|
|
|
x- define endianess for SANE_FRAME_RAW
|
|
|
|
- add a pointer "next" to the device handle to make linked lists instead of arrays(?)
|
|
|
|
- when an option is set with sane_control_option that changes the image significantly
|
|
(e.g. exposure) invalidate the preview by setting SANE_INFO_INVALIDATE_PREVIEW
|
|
|
|
x- fix sane_strstatus (remove const)
|
|
|
|
- add SANE_String sane_verbose_error(Sane_Handle h), to show backend-specific
|
|
error messages. The error string always refers to the last error reported by the backend.
|
|
So the frontend would call this when a SANE API call returned with an error status.
|
|
E.g. out-of-memory in scanner hardware or "Couldn't open file foo".
|
|
Check for therad-safety problems. If the handle parameters is used, no errors can
|
|
be printed before sane_open has succeeded.
|
|
|
|
- The network protocoll must be updated to reflect the changes to the SANE standard
|
|
- there were ideas to use UDP instead of TCP
|
|
- let the server define a port number for the data port to avoid firewall
|
|
problems?
|
|
- maybe it's possible to avoid the data port at all?
|
|
- add the numbers of the RPCs
|
|
- check if the callbacks are implemented according to the standard
|
|
|
|
- How to name the SANE2 header? sane-2.h or sane2.h?
|
|
|
|
- Split sane_cancel and add sane_end()?
|
|
|
|
x- Update contact section
|
|
|
|
- section with implementation notes (currently in backend-writing.txt).
|
|
|
|
- Check grammar & spelling
|
|
|
|
- check too long lines
|
|
|
|
- check defective references
|
|
|
|
- update index
|
|
|
|
- Check that all headlines are in capital letters
|
|
|
|
x- Changebar for sane_read
|
|
|
|
x- check for correct quotation marks |