<H2>NAME</H2><PRE>
|
|
sane-pint - SANE backend for scanners that use the PINT device driver
|
|
|
|
|
|
</PRE>
|
|
<H2>DESCRIPTION</H2><PRE>
|
|
The <B>sane-pint</B> library implements a SANE (Scanner Access Now Easy) back-
|
|
end that provides generic access to hand-held and flatbed scanners
|
|
using the PINT (PINT Is Not Twain) device driver. The PINT driver is
|
|
being actively developed on the OpenBSD platform, and has been ported
|
|
to a few other *nix-like operating systems.
|
|
|
|
PINT is designed to provide an <B><A HREF="ioctl.2.html">ioctl(2)</A></B> interface to many different
|
|
scanner types. However, this backend has only been tested with flatbed
|
|
single-pass scanners, and more work will probably be required to get it
|
|
to use other scanner types successfully.
|
|
|
|
If have successfully used the PINT driver with your scanner, but it
|
|
does not work using this SANE backend, please let us know. To do this,
|
|
send a mail with the relevant information for your scanner to
|
|
<I>sane-devel@lists.alioth.debian.org</I>. Have a look at
|
|
http://www.sane-project.org/mailing-lists.html concerning subscription
|
|
to sane-devel.
|
|
|
|
|
|
</PRE>
|
|
<H2>DEVICE NAMES</H2><PRE>
|
|
This backend expects device names of the form:
|
|
|
|
<I>special</I>
|
|
|
|
Where <I>special</I> is the UNIX path-name for the special device that corre-
|
|
sponds to the scanner. The special device name must be a PINT device
|
|
or a symlink to such a device. For example, under NetBSD or OpenBSD,
|
|
such a device name could be <I>/dev/ss0</I> or <I>/dev/scan0</I>.
|
|
|
|
|
|
</PRE>
|
|
<H2>CONFIGURATION</H2><PRE>
|
|
The contents of the <I>pint.conf</I>. file is a list of device names that
|
|
correspond to PINT scanners. Empty lines and lines starting with a
|
|
hash mark (#) are ignored. A sample configuration file is shown below:
|
|
|
|
/dev/scanner
|
|
# this is a comment
|
|
/dev/ss1
|
|
|
|
|
|
</PRE>
|
|
<H2>FILES</H2><PRE>
|
|
<I>/usr/local/etc/sane.d/pint.conf</I>
|
|
The backend configuration file (see also description of
|
|
<B>SANE_CONFIG_DIR</B> below).
|
|
|
|
<I>/usr/local/lib/sane/libsane-pint.a</I>
|
|
The static library implementing this backend.
|
|
|
|
<I>/usr/local/lib/sane/libsane-pint.so</I>
|
|
The shared library implementing this backend (present on systems
|
|
that support dynamic loading).
|
|
|
|
|
|
</PRE>
|
|
<H2>ENVIRONMENT</H2><PRE>
|
|
<B>SANE_CONFIG_DIR</B>
|
|
This environment variable specifies the list of directories that
|
|
may contain the configuration file. Under UNIX, the directories
|
|
are separated by a colon (`:'), under OS/2, they are separated
|
|
by a semi-colon (`;'). If this variable is not set, the config-
|
|
uration file is searched in two default directories: first, the
|
|
current working directory (".") and then in
|
|
/usr/local/etc/sane.d. If the value of the environment variable
|
|
ends with the directory separator character, then the default
|
|
directories are searched after the explicitly specified directo-
|
|
ries. For example, setting <B>SANE_CONFIG_DIR</B> to "/tmp/config:"
|
|
would result in directories "tmp/config", ".", and
|
|
"/usr/local/etc/sane.d" being searched (in this order).
|
|
|
|
<B>SANE_DEBUG_PINT</B>
|
|
If the library was compiled with debug support enabled, this
|
|
environment variable controls the debug level for this backend.
|
|
E.g., a value of 128 requests all debug output to be printed.
|
|
Smaller levels reduce verbosity.
|
|
|
|
|
|
</PRE>
|
|
<H2>SEE ALSO</H2><PRE>
|
|
<B><A HREF="sane.7.html">sane(7)</A></B>
|
|
|
|
|
|
</PRE>
|
|
<H2>AUTHOR</H2><PRE>
|
|
Gordon Matzigkeit, adapted from existing backends written by David Mos-
|
|
berger.
|
|
|
|
|
|
</PRE>
|
|
<H2>BUGS</H2><PRE>
|
|
There are minor roundoff errors when adjusting the ranges, since PINT
|
|
uses units of 1/1200 of an inch, and SANE normally uses millimeters.
|
|
Symptoms of these errors are skewed images. This should really be
|
|
fixed (no pun intended) as soon as possible, but I just don't know/care
|
|
enough about fixed-point representation and roundoff errors to do this
|
|
correctly. Workaround: use inches as the scanning unit, and everything
|
|
usually works fine.
|
|
|
|
The PINT 0.5e interface does not provide a way to determine valid
|
|
ranges for DPI, modes, and scan sizes. So, the SANE backend queries
|
|
the PINT device, and dynamically discovers valid ranges by doing a
|
|
binary search. This means that the driver takes longer to initialize
|
|
than seems necessary.
|
|
|
|
Resetting the scanner does not seem to work (at least not on my HP
|
|
ScanJet 4p). For that reason, the driver sends a SCIOCRESTART, then
|
|
gobbles up any remaining input until it hits EOF.
|
|
|
|
Not all of the scanners have been identified (i.e. whether they are
|
|
flatbed or handheld).
|
|
|
|
X and Y resolutions are assumed to be the same.
|
|
|
|
No testing has been done on three-pass or handheld scanners, or with
|
|
Automatic Document Feeder support.
|
|
|
|
sane-backends 1.0.13 13 May 1998 <B><A HREF="sane-pint.5.html">sane-pint(5)</A></B>
|
|