<H2>NAME</H2><PRE>
|
|
sane-mustek_pp - SANE backend for Mustek parallel port flatbed scanners
|
|
|
|
|
|
</PRE>
|
|
<H2>DESCRIPTION</H2><PRE>
|
|
The <B>sane-mustek_pp</B> library implements a SANE (Scanner Access Now Easy)
|
|
backend that provides access to Mustek parallel port flatbed scanners
|
|
and OEM versions.
|
|
|
|
There are 2 classes of Mustek parallel port scanners: regular <B>CCD</B> (cold
|
|
cathode device) scanners and <B>CIS</B> (contact image sensor) scanners.
|
|
|
|
The current version of this backend supports both CCD type scanners and
|
|
CIS type scanners.
|
|
|
|
The following scanners might work with this backend:
|
|
|
|
<B>CCD</B> <B>scanners</B>
|
|
Model: ASIC ID: CCD Type: works:
|
|
--------------------------------------------------------------
|
|
SE 6000 P 1013 00 yes
|
|
SM 4800 P 1013/1015 04/01 yes
|
|
SE 1200 ED Plus 1015 01 no
|
|
SM 1200 ED Plus 1015 01 no
|
|
SE 12000 P 1505 05 no
|
|
600 III EP Plus 1013/1015 00/01 yes
|
|
SE 600 SEP 1013 ?? yes
|
|
600 II EP ???? ?? no
|
|
MD9848 1015 00 yes
|
|
Gallery 4800 ???? ?? yes
|
|
Viviscan Compact II 1013 00 yes
|
|
|
|
<B>CIS</B> <B>scanners</B>
|
|
Model: ASIC ID: works:
|
|
-----------------------------------------------
|
|
Mustek 600 CP & 96 CP 1015 yes (*)
|
|
Mustek 1200 CP 1015 yes
|
|
Mustek 1200 CP+ 1015 yes
|
|
|
|
OEM versions Original works
|
|
--------------------------------------------------
|
|
Medion/LifeTec/Tevion
|
|
MD/LT 9350/9351 1200 CP yes
|
|
MD/LT 9850/9851 1200 CP maybe (**)
|
|
MD/LT 9858 1200 CP probably
|
|
MD/LT 9890/9891 1200 CP yes
|
|
Targa
|
|
Funline TS12EP 1200 CP yes
|
|
Funline TS6EP 600 CP yes
|
|
Trust
|
|
Easy Connect 9600+ 600 CP yes
|
|
Cybercom
|
|
9352 1200 CP yes (***)
|
|
|
|
(*) Calibration problems existed with earlier version of this
|
|
driver. They seem to be solved now.
|
|
|
|
(**) Problems have been reported in the past for the MD/LT9850 type
|
|
(striped scans, head moving in wrong direction at some resolu-
|
|
tions). It is not known whether the current version of the
|
|
driver still has these problems.
|
|
|
|
<B>IF</B> <B>YOU</B> <B>HEAR</B> <B>LOUD</B> <B>CLICKING</B> <B>NOISES,</B> <B>IMMEDIATELY</B> <B>UNPLUG</B> <B>THE</B> <B>SCANNER</B> <B>!</B>
|
|
(This holds for any type of scanner).
|
|
|
|
(***) Possibly, the engine_delay parameter has to be set to 1 ms for
|
|
accurate engine movements.
|
|
|
|
Please note that this backend is still under construction. Certain mod-
|
|
els are currently not supported and some may never be because the com-
|
|
munication protocol is still unknown (eg., SE 12000 P).
|
|
|
|
Some scanners work faster when <B>EPP/ECP</B> is enabled in the BIOS. EPP mode
|
|
however may lead to hard-locks on some Linux systems. If that is the
|
|
case for you, you can either disable ECP/EPP in your BIOS or disable it
|
|
in the backend itself (see GLOBAL OPTIONS).
|
|
|
|
Note that the backend needs to run as root or has to have appropriate
|
|
access rights to <I>/dev/parport*</I> if libieee1284 support is compiled in.
|
|
To allow user access to the scanner run the backend through the network
|
|
interface (see <B><A HREF="saned.8.html">saned(8)</A></B> and <B><A HREF="sane-net.5.html">sane-net(5)</A></B>). Note also that the backend
|
|
<I>does</I> <I>not</I> support <I>parport</I> <I>sharing</I>, i.e. if you try printing while scan-
|
|
ning, your computer may crash. To enable parport sharing, you have to
|
|
enable <B><A HREF="libieee1284.3.html">libieee1284(3)</A></B> at compile time. You may also have to enable the
|
|
backend explicitly in your <I>dll.conf</I>. Just remove the hash mark in the
|
|
line "mustek_pp".
|
|
|
|
|
|
</PRE>
|
|
<H2>DEVICE DEFINITION</H2><PRE>
|
|
This backend allows multiple devices being defined and configured via
|
|
the <I>mustek</I><B>_</B><I>pp.conf</I> file (even simultaneously, provided that they are
|
|
connected to different parallel ports). Please make sure to edit this
|
|
file <B>before</B> you use the backend.
|
|
|
|
A device can be defined as follows:
|
|
|
|
<I>scanner</I> <I><name></I> <I><port</I> <I>name></I> <I><driver></I>
|
|
|
|
where
|
|
|
|
<B><name></B> is an arbitrary name for the device, optionally enclosed by dou-
|
|
ble quotes, for instance "LifeTec 9350".
|
|
|
|
<B><port</B> <B>name></B> is the name of the parallel port to which the device is
|
|
connected. In case libieee1284 is used for communication with
|
|
the port <I>(default</I> <I>setup)</I>, valid port names are <B>parport0</B>, <B>par-</B>
|
|
<B>port1</B>, and <B>parport2</B>.
|
|
|
|
In case the backend is configured for raw IO <I>(old</I> <I>setup)</I>, port ad-
|
|
dresses have to be used instead of port names: <B>0x378</B>, <B>0x278</B>, or <B>0x3BC</B>.
|
|
The mapping of parallel ports (lp0, lp1, and lp2) to these addresses
|
|
can be different for different Linux kernel versions. For instance, if
|
|
you are using a Kernel 2.2.x or better and you have only one parallel
|
|
port, this port is named lp0 regardless of the base address. However,
|
|
this backend requires the base address of your port. If you are not
|
|
sure which port your scanner is connected to, have a look at your
|
|
<I>/etc/conf.modules</I>, <I>/etc/modules.conf</I> and/or <I>/proc/ioports</I>.
|
|
|
|
If you are unsure which port to use, you can use the magic value <B>*</B> to
|
|
probe for your scanner.
|
|
|
|
<B><driver></B> is the driver to use for this device. Currently available
|
|
drivers are:
|
|
|
|
<B>cis600</B> : for 600 CP, 96 CP & OEM versions
|
|
<B>cis1200</B> : for 1200 CP & OEM versions
|
|
<B>cis1200+</B> : for 1200 CP+ & OEM versions
|
|
<B>ccd300</B> : for 600 IIIE P & OEM version
|
|
|
|
<B>Choosing</B> <B>the</B> <B>wrong</B> <B>driver</B> <B>can</B> <B>damage</B> <B>your</B> <B>scanner!</B>
|
|
Especially, using the 1200CP settings on a 600CP can be harmful.
|
|
If the scanner starts making a loud noise, turn it off immedi-
|
|
ately !!!
|
|
|
|
Using the cis600 driver on a 1200CP or a 1200CP+ is probably not dan-
|
|
gerous. The cis1200+ driver also works for the 1200CP, and using the
|
|
cis1200 driver on a 1200CP+ will typically result in scans that cover
|
|
only half of the width of the scan area (also not dangerous).
|
|
|
|
If unsure about the exact model of your OEM version, check the optical
|
|
resolution in the manual or on the box: the 600CP has a maximum optical
|
|
resolution of 300x600 DPI, whereas the 1200CP and 1200CP+ have a maxi-
|
|
mum optical resolution of 600x1200 DPI.
|
|
|
|
Examples:
|
|
|
|
scanner "LifeTec 9350" 0x378 cis1200
|
|
|
|
scanner Mustek_600CP 0x378 cis600
|
|
|
|
scanner Mustek_600IIIEP * ccd300
|
|
|
|
If in doubt which port you have to use, or whether your scanner is de-
|
|
tected at all, you can use <I>sane-find-scanner</I> <I>-p</I> to probe all configured
|
|
ports.
|
|
|
|
|
|
</PRE>
|
|
<H2>CONFIGURATION</H2><PRE>
|
|
The contents of the <I>mustek</I><B>_</B><I>pp.conf</I> file is a list of device definitions
|
|
and device options that correspond to Mustek scanners. Empty lines and
|
|
lines starting with a hash mark (#) are ignored. Options have the fol-
|
|
lowing format:
|
|
|
|
<I>option</I> <I><name></I> <I>[<value>]</I>
|
|
|
|
Depending on the nature of the option, a value may or may not be
|
|
present. Options always apply to the scanner definition that precedes
|
|
them. There are no global options. Options are also driver-specific:
|
|
not all drivers support all possible options.
|
|
|
|
<B>Common</B> <B>options</B>
|
|
<B>bw</B> <B><value></B>
|
|
Black/white discrimination value to be used during lineart scan-
|
|
ning. Pixel values below this value are assumed to be black,
|
|
values above are assumed to be white.
|
|
Default value: 127
|
|
Minimum: 0
|
|
Maximum: 255
|
|
|
|
Example: option bw 150
|
|
|
|
<B>CIS</B> <B>driver</B> <B>options</B>
|
|
<B>top_adjust</B> <B><value></B>
|
|
Vertical adjustment of the origin, expressed in millimeter
|
|
(floating point). This option can be used to calibrate the po-
|
|
sition of the origin, within certain limits. Note that CIS scan-
|
|
ners are probably temperature sensitive, and that a certain in-
|
|
accuracy may be hard to avoid. Differences in offset between
|
|
runs in the order of 1 to 2 mm are not unusual.
|
|
Default value: 0.0
|
|
Minimum: -5.0
|
|
Maximum: 5.0
|
|
|
|
Example: option top_adjust -2.5
|
|
|
|
<B>slow_skip</B>
|
|
Turns fast skipping to the start of the scan region off. When
|
|
the region to scan does not start at the origin, the driver will
|
|
try to move the scanhead to the start of the scan area at the
|
|
fastest possible speed. On some models, this may not work, re-
|
|
sulting in large inaccuracies (up to centimeters). By setting
|
|
this option, the driver is forced to use normal speed during
|
|
skipping, which can circumvent the accuracy problems. Currently,
|
|
there are no models for which these inaccuracy problems are
|
|
known to occur.
|
|
|
|
By default, fast skipping is used.
|
|
|
|
Example: option slow_skip
|
|
|
|
<B>engine_delay</B> <B><value></B>
|
|
Under normal circumstances, it is sufficient for the driver to
|
|
wait for the scanner signaling that the engine is stable, before
|
|
a new engine command can be transmitted. In rare cases, certain
|
|
scanners and/or parallel port chipsets appear to prevent reli-
|
|
able detection of the engine state. As a result, engine commands
|
|
are transmitted too soon and the movement of the scanner head
|
|
becomes unreliable. Inaccuracies ranging up to 10 cm over the
|
|
whole vertical scan range have been reported. To work around
|
|
this problem, the engine_delay option can be set. If it is set,
|
|
the driver waits an additional amount of time after every engine
|
|
command, equal to the engine_delay parameter, expressed in mil-
|
|
liseconds. It practice an engine_delay of 1 ms is usually suffi-
|
|
cient. The maximum delay is 100 ms.
|
|
|
|
Note that every additional ms of delay can add up to 14 seconds
|
|
to the total scanning time (highest resolution), so an as small
|
|
as possible value is preferred.
|
|
|
|
Default value: 0
|
|
Minimum: 0
|
|
Maximum: 100
|
|
|
|
Example: option engine_delay 1
|
|
|
|
<B>CCD</B> <B>driver</B> <B>options</B>
|
|
<B>top</B> <B><value></B>
|
|
Number of scanlines to skip to the start of the scan area. The
|
|
number can be any positive integer. Values known to me are 47
|
|
and 56.
|
|
|
|
Default value: 47
|
|
Minimum: 0
|
|
Maximum: none
|
|
|
|
Example: option top 56
|
|
|
|
<B>waitbank</B> <B><value></B>
|
|
The number of usecs to wait for a bank change. You should not
|
|
touch this value actually. May be any positive integer
|
|
|
|
Default value: 700
|
|
Minimum: 0
|
|
Maximum: none
|
|
|
|
Example: option waitbank 700
|
|
|
|
A sample configuration file is shown below:
|
|
|
|
#
|
|
# LifeTec/Medion 9350 on port 0x378
|
|
#
|
|
scanner "LifeTec 9350" 0x378 cis1200
|
|
|
|
# Some calibration options (examples!).
|
|
option bw 127
|
|
option top_skip -0.8
|
|
|
|
#
|
|
# A Mustek 600CP on port 0x3BC
|
|
#
|
|
scanner "Mustek 600CP" 0x3BC cis600
|
|
|
|
# Some calibration options (examples!).
|
|
option bw 120
|
|
option top_skip 1.2
|
|
|
|
#
|
|
# A Mustek 1200CP+ on port 0x278
|
|
#
|
|
scanner "Mustek 1200CP plus" 0x278 cis1200+
|
|
|
|
# Some calibration options (examples!).
|
|
option bw 130
|
|
option top_skip 0.2
|
|
|
|
#
|
|
# A Mustek 600 III EPP on port parport0
|
|
#
|
|
scanner "Mustek 600 III EPP" parport0 ccd300
|
|
|
|
# Some calibration options (examples!).
|
|
option bw 130
|
|
option top 56
|
|
|
|
|
|
</PRE>
|
|
<H2>GLOBAL OPTIONS</H2><PRE>
|
|
You can control the overall behaviour of the <B>sane-stek_pp</B> backend by
|
|
global options which precede any scanner definition in the
|
|
<I>mustek</I><B>_</B><I>pp.conf</I> file.
|
|
|
|
Currently, there is only one global option:
|
|
|
|
<B>Global</B> <B>options</B>
|
|
<B>no_epp</B> Disable parallel port mode EPP: works around a known bug in the
|
|
Linux parport code. Enable this option, if the backend hangs
|
|
when trying to access the parallel port in EPP mode.
|
|
|
|
Default value: use EPP
|
|
|
|
Example: option no_epp
|
|
|
|
|
|
</PRE>
|
|
<H2>FILES</H2><PRE>
|
|
<I>/usr/local/etc/sane.d/mustek</I><B>_</B><I>pp.conf</I>
|
|
The backend configuration file (see also description of
|
|
<B>SANE_CONFIG_DIR</B> below).
|
|
|
|
<I>/usr/local/lib/sane/libsane-mustek</I><B>_</B><I>pp.a</I>
|
|
The static library implementing this backend.
|
|
|
|
<I>/usr/local/lib/sane/libsane-mustek</I><B>_</B><I>pp.so</I>
|
|
The shared library implementing this backend (present on systems
|
|
that support dynamic loading).
|
|
|
|
|
|
</PRE>
|
|
<H2>ENVIRONMENT</H2><PRE>
|
|
<B>SANE_CONFIG_DIR</B>
|
|
This environment variable specifies the list of directories that
|
|
may contain the configuration file. On *NIX systems, the direc-
|
|
tories are separated by a colon (`:'), under OS/2, they are sep-
|
|
arated by a semi-colon (`;'). If this variable is not set, the
|
|
configuration file is searched in two default directories:
|
|
first, the current working directory (".") and then in <I>/usr/lo-</I>
|
|
<I>cal/etc/sane.d</I>. If the value of the environment variable ends
|
|
with the directory separator character, then the default direc-
|
|
tories are searched after the explicitly specified directories.
|
|
For example, setting <B>SANE_CONFIG_DIR</B> to "/tmp/config:" would re-
|
|
sult in directories <I>tmp/config</I>, <I>.</I>, and <I>/usr/local/etc/sane.d</I> be-
|
|
ing searched (in this order).
|
|
|
|
<B>SANE_DEBUG_MUSTEK_PP</B>
|
|
If the library was compiled with debug support enabled, this en-
|
|
vironment variable controls the debug level for this backend.
|
|
E.g., a value of 128 requests all debug output to be printed.
|
|
Smaller levels reduce verbosity.
|
|
|
|
level debug output
|
|
--------------------------------------
|
|
0 nothing
|
|
1 errors
|
|
2 warnings & minor errors
|
|
3 additional information
|
|
4 debug information
|
|
5 code flow (not supported yet)
|
|
6 special debug information
|
|
|
|
<B>SANE_DEBUG_SANEI_PA4S2</B>
|
|
This variable sets the debug level for the SANE interface for
|
|
the Mustek chipset A4S2. Note that enabling this will spam your
|
|
terminal with some million lines of debug output.
|
|
|
|
level debug output
|
|
----------------------------
|
|
0 nothing
|
|
1 errors
|
|
2 warnings
|
|
3 things nice to know
|
|
4 code flow
|
|
5 detailed code flow
|
|
6 everything
|
|
|
|
|
|
</PRE>
|
|
<H2>SEE ALSO</H2><PRE>
|
|
<B><A HREF="sane.7.html">sane(7)</A></B>, <B><A HREF="sane-mustek.5.html">sane-mustek(5)</A></B>, <B><A HREF="sane-net.5.html">sane-net(5)</A></B>, <B><A HREF="saned.8.html">saned(8)</A></B>, <B><A HREF="sane-find-scanner.1.html">sane-find-scanner(1)</A></B>,
|
|
<B><A HREF="scanimage.1.html">scanimage(1)</A></B>
|
|
|
|
For latest bug fixes and information see
|
|
<I>http://www.penguin-breeder.org/sane/mustek</I><B>_</B><I>pp/</I>
|
|
|
|
|
|
For additional information on the CIS driver, see
|
|
<I>http://home.scarlet.be/eddy</I><B>_</B><I>de</I><B>_</B><I>greef/</I>
|
|
|
|
|
|
</PRE>
|
|
<H2>AUTHORS</H2><PRE>
|
|
Jochen Eisinger
|
|
<<I>jochen</I> <I>at</I> <I>penguin-breeder</I> <I>dot</I> <I>org</I>>
|
|
Eddy De Greef
|
|
<<I>eddy</I><B>_</B><I>de</I><B>_</B><I>greef</I> <I>at</I> <I>scarlet</I> <I>dot</I> <I>be</I>>
|
|
|
|
|
|
</PRE>
|
|
<H2>BUGS</H2><PRE>
|
|
Too many... please send bug reports to <I>sane-devel@alioth-lists.de-</I>
|
|
<I>bian.net</I> (note that you have to subscribe first to the list before you
|
|
can send emails... see <I>http://www.sane-project.org/mailing-lists.html</I>).
|
|
|
|
|
|
</PRE>
|
|
<H2>BUG REPORTS</H2><PRE>
|
|
If something doesn't work, please contact us (Jochen for the CCD scan-
|
|
ners, Eddy for the CIS scanners). But we need some information about
|
|
your scanner to be able to help you...
|
|
|
|
<I>SANE</I> <I>version</I>
|
|
Run <I>scanimage</I> <I>-V</I> to determine this.
|
|
|
|
<I>the</I> <I>backend</I> <I>version</I> <I>and</I> <I>your</I> <I>scanner</I> <I>hardware</I>
|
|
Run <I>SANE</I><B>_</B><I>DEBUG</I><B>_</B><I>MUSTEK</I><B>_</B><I>PP=128</I> <I>scanimage</I> <I>-L</I> as root. If you don't
|
|
get any output from the <B>sane-mustek_pp</B> backend, make sure a line
|
|
"mustek_pp" is included into your <I>/usr/lo-</I>
|
|
<I>cal/etc/sane.d/dll.conf</I>. If your scanner isn't detected, make
|
|
sure you've defined the right port address in your
|
|
<I>mustek</I><B>_</B><I>pp.conf</I>.
|
|
|
|
<I>the</I> <I>name</I> <I>of</I> <I>your</I> <I>scanner/vendor</I> <I>also</I> <I>a</I> <I>worthy</I> <I>information.</I> <I>Please</I> <I>also</I>
|
|
<I>include</I> <I>the</I>
|
|
optical resolution and lamp type of your scanner, both can be
|
|
found in the manual of your scanner.
|
|
|
|
<I>any</I> <I>further</I> <I>comments</I>
|
|
if you have comments about the documentation (what could be done
|
|
better), or you think I should know something, please include
|
|
it.
|
|
|
|
13 Jul 2008 <B><A HREF="sane-mustek_pp.5.html">sane-mustek_pp(5)</A></B>
|
|
</PRE>
|
|