sane-project-website/man/sane-microtek.5.html

179 wiersze
7.5 KiB
HTML

<HTML>
<HEAD>
<TITLE>sane-microtek.5</TITLE>
</HEAD>
<BODY BGCOLOR=#FFFFFF TEXT=#000000><H1 ALIGN=CENTER><IMG SRC="/images/sane.png" HEIGHT=117 WIDTH=346></H1>
<H1>sane-microtek.5</H1>
<HR>
<PRE>
<!-- Manpage converted by man2html 3.0.1 -->
<B><A HREF="sane-microtek.5.html">sane-microtek(5)</A></B> SANE Scanner Access Now Easy <B><A HREF="sane-microtek.5.html">sane-microtek(5)</A></B>
</PRE>
<H2>NAME</H2><PRE>
sane-microtek - SANE backend for Microtek scanners
</PRE>
<H2>DESCRIPTION</H2><PRE>
The <B>sane-microtek</B> library implements a SANE (Scanner Access Now Easy)
backend that provides access to the "second generation" Microtek scan-
ners. At present, the following hardware is known to work with this
backend:
Microtek ScanMaker E2, E3, E6
Microtek ScanMaker II, IIG, IIHR, IISP, III
Microtek ScanMaker 35t, 35t+, 45t
Microtek ScanMaker 600GS, 600ZS (see bug notes)
Agfa StudioScan
Agfa StudioScan II, StudioScan IIsi
Agfa Arcus II (but not the "Arcus")
Agfa DuoScan (preliminary)
Vobis "Highscreen Realscan"
Microtek Color PageWiz (preliminary)
Transparent Media Adapter
Document AutoFeeder
The driver supports line art, halftone, 8bpp gray, and 24bpp color
scans at normal and "expanded" resolutions (i.e. 1200x1200 on an E6),
fast scans for color previews, and downloadable gamma tables.
The supported scanners are all SCSI scanners. However, some parallel
port models may work (under Linux), if they use a parport-&gt;scsi chip,
and if you can find a scsi-&gt;parport driver. This is known to be the
case for the Color PageWiz.
The driver does <B>not</B> support the newest Microtek scanners, such as the
V330 and V660, which use a new and very different SCSI-II command set.
For those, try the alternate <B><A HREF="microtek2.5.html">microtek2(5)</A></B> backend. Most non-SCSI scan-
ners would use the new command set. Most scanners newer than the Scan-
maker E6 would use the new command set.
If you own a Microtek scanner other than the ones listed above, tell us
what happens --- see the <B>BUGS</B> section at the end of this document.
Although this manual page is generally updated with each release, up-
to-date information on new releases and extraneous helpful hints are
available from the backend homepage:
<I>http://www.mir.com/mtek/</I>
</PRE>
<H2>DEVICE NAMES</H2><PRE>
This backend expects device names of the form:
<I>special</I>
Where <I>special</I> is the UNIX path-name for the special device that corre-
sponds to the scanner. The special device name must be a generic SCSI
device or a symlink to such a device. Under Linux, such a device name
could be <I>/dev/sga</I> or <I>/dev/sge</I>, for example.
</PRE>
<H2>CONFIGURATION</H2><PRE>
The contents of the <I>microtek.conf</I> file is a list of device names that
correspond to Microtek scanners. Empty lines and lines starting with a
hash mark (#) are ignored. A sample configuration file is shown below:
/dev/scanner
# this is a comment
/dev/sge
The configuration file may also contain the special tokens <I>norealcal</I> or
<I>noprecal</I>. <I>norealcal</I> will disable the use of magic, undocumented scan-
ner calibration commands which are known to work on the E6, but may not
work with other models. <I>noprecal</I> will disable logic which tries to
avoid scanner precalibration. This logic would only have been acti-
vated if the magic calibration code was turned off.
</PRE>
<H2>FILES</H2><PRE>
<I>/usr/local/etc/sane.d/microtek.conf</I>
The backend configuration file (see also description of
<B>SANE_CONFIG_DIR</B> below).
<I>/usr/local/lib/sane/libsane-microtek.a</I>
The static library implementing this backend.
<I>/usr/local/lib/sane/libsane-microtek.so</I>
The shared library implementing this backend (present on systems
that support dynamic loading).
</PRE>
<H2>ENVIRONMENT</H2><PRE>
<B>SANE_CONFIG_DIR</B>
This environment variable specifies the list of directories that
may contain the configuration file. On *NIX systems, the direc-
tories are separated by a colon (`:'), under OS/2, they are sep-
arated by a semi-colon (`;'). If this variable is not set, the
configuration file is searched in two default directories:
first, the current working directory (".") and then in <I>/usr/lo-</I>
<I>cal/etc/sane.d</I>. If the value of the environment variable ends
with the directory separator character, then the default direc-
tories are searched after the explicitly specified directories.
For example, setting <B>SANE_CONFIG_DIR</B> to "/tmp/config:" would re-
sult in directories <I>tmp/config</I>, <I>.</I>, and <I>/usr/local/etc/sane.d</I> be-
ing searched (in this order).
<B>SANE_DEBUG_MICROTEK</B>
If the library was compiled with debugging support enabled, this
environment variable controls the debug level for this backend.
A value of 128 requests maximally copious debug output; smaller
levels reduce verbosity.
</PRE>
<H2>SEE ALSO</H2><PRE>
<B><A HREF="sane.7.html">sane(7)</A></B>, <B><A HREF="sane-scsi.5.html">sane-scsi(5)</A></B>, <B><A HREF="sane-microtek2.5.html">sane-microtek2(5)</A></B>
</PRE>
<H2>AUTHOR</H2><PRE>
Matt Marjanovic
</PRE>
<H2>BUGS</H2><PRE>
Known bugs/limitations are:
Brightness and contrast broken.
The 600GS is grayscale only, and will lock up if you select
color. (Unfortunately, the 600GS and 600ZS are indistinguish-
able by software.)
i.e. don't complain about these --- but if brightness and/or contrast
<B>do</B> work for you, please tell me.
If your scanner locks up, try setting the <I>norealcal</I> or <I>noprecal</I> option
in the configuration file (first one, then both), and see if it helps.
(If it does, report it.)
Send lengthy bug reports and new scanner information to
<I>mtek-bugs@mir.com</I>. All bug reports and new scanner inquiries should
include an error log file. You can generate copious stderr output by
setting the <B>SANE_DEBUG_MICROTEK</B> environment variable described above.
For example:
setenv SANE_DEBUG_MICROTEK 128
More general comments, suggestions, and inquiries about frontends or
SANE should go to <I>sane-devel@alioth-lists.debian.net</I>, the SANE Develop-
ers mailing list. Have a look at <I>http://www.sane-project.org/mail-</I>
<I>ing-lists.html</I> concerning subscription to sane-devel.
13 Jul 2008 <B><A HREF="sane-microtek.5.html">sane-microtek(5)</A></B>
</PRE>
<HR>
<ADDRESS>
Man(1) output converted with
<a href="http://www.oac.uci.edu/indiv/ehood/man2html.html">man2html</a>
</ADDRESS>
</BODY>
</HTML>