<H2>NAME</H2><PRE>
sane-agfafocus - SANE backend for AGFA Focus flatbed scanners
</PRE>
<H2>DESCRIPTION</H2><PRE>
The <B>sane-agfafocus</B> library implements a SANE (Scanner Access Now Easy)
backend that provides access to AGFA Focus flatbed scanners. At
present, the following scanners are supported from this backend:
AGFA Focus GS Scanner (6 bit gray scale) (untested)
AGFA Focus Lineart Scanner (lineart) (untested)
AGFA Focus II (8 bit gray scale) (untested)
AGFA Focus Color (24 bit color 3-pass)
AGFA Focus Color Plus (24 bit color 3-pass)
Siemens S9036 (8 bit gray scale) (untested)
The driver supports line art, 6bpp and 8bpp gray, 18bpp and 24bpp color
scans.
If you own a scanner other than the ones listed above that works with
this backend, please let us know by sending the scanner's model name,
SCSI id, and firmware revision to <I>sane-devel@alioth-lists.debian.net</I>.
Have a look at <I>http://www.sane-project.org/mailing-lists.html</I> concern-
ing subscription to sane-devel.
All of these scanners are pre-SCSI-2, and do not even report properly
to SCSI Inquiry. This is typically evident in SCSI bus scans, where
the scanner will come up with only garbage as vendor and models
strings.
</PRE>
<H2>DEVICE NAMES</H2><PRE>
This backend expects device names of the form:
<I>special</I>
where <I>special</I> is the path-name for the special device that corresponds
to a SCSI scanner. For SCSI scanners, the special device name must be a
generic SCSI device or a symlink to such a device. Under Linux, such a
device name could be <I>/dev/sga</I> or <I>/dev/sge</I>, for example. See
<B><A HREF="sane-scsi.5.html">sane-scsi(5)</A></B> for details.
</PRE>
<H2>CONFIGURATION</H2><PRE>
The contents of the <I>agfafocus.conf</I> file is a list of device names that
correspond to AGFA Focus scanners. Empty lines and lines starting with
a hash mark (#) are ignored. A sample configuration file is shown be-
low:
/dev/scanner
# this is a comment
/dev/sge
</PRE>
<H2>FILES</H2><PRE>
<I>/etc/sane.d/agfafocus.conf</I>
The backend configuration file (see also description of
<B>SANE_CONFIG_DIR</B> below).
<I>/usr/lib/libsane-agfafocus.a</I>
The static library implementing this backend.
<I>/usr/lib/libsane-agfafocus.so</I>
The shared library implementing this backend (present on systems
that support dynamic loading).
</PRE>
<H2>ENVIRONMENT</H2><PRE>
<B>SANE_CONFIG_DIR</B>
This environment variable specifies the list of directories that
may contain the configuration file. On *NIX systems, the direc-
tories are separated by a colon (`:'), under OS/2, they are sep-
arated by a semi-colon (`;'). If this variable is not set, the
configuration file is searched in two default directories:
first, the current working directory (".") and then in <I>/usr/lo-</I>
<I>cal/etc/sane.d</I>. If the value of the environment variable ends
with the directory separator character, then the default direc-
tories are searched after the explicitly specified directories.
For example, setting <B>SANE_CONFIG_DIR</B> to "/tmp/config:" would re-
sult in directories <I>tmp/config</I>, <I>.</I>, and <I>/usr/local/etc/sane.d</I> be-
ing searched (in this order).
<B>SANE_DEBUG_AGFAFOCUS</B>
If the library was compiled with debug support enabled, this en-
vironment variable controls the debug level for this backend.
E.g., a value of 128 requests all debug output to be printed.
Smaller levels reduce verbosity. <B>SANE_DEBUG_AGFAFOCUS</B> values:
Number Remark
0 print important errors (printed each time)
1 print errors
2 print sense
3 print warnings
4 print scanner-inquiry
5 print information
6 print less important information
7 print called procedures
8 print reader_process messages
10 print called sane-init-routines
11 print called sane-procedures
12 print sane infos
13 print sane option-control messages
</PRE>
<H2>MISSING FUNCTIONALITY</H2><PRE>
Uploading of dither matrices and tonecurves has been implemented, but
so far has not proven to be useful for anything. For this reason these
options have been disabled.
</PRE>
<H2>BUGS</H2><PRE>
The scanners that do not support disconnect have problems with SCSI
timeouts if the SCSI bus gets loaded, eg. if you do a kernel build at
the same time as scanning. To see if your scanner supports disconnect,
run <I>SANE</I><B>_</B><I>DEBUG</I><B>_</B><I>AGFAFOCUS=128</I> <I>scanimage</I> <I>-L</I> in a terminal and look for
the "disconnect:" line.
</PRE>
<H2>DEBUG</H2><PRE>
If you have problems with SANE not detecting your scanner, make sure
the Artec backend is disabled. Somehow, this backend causes at least
my scanner not to respond correctly to SCSI inquiry commands.
If you encounter a bug please set the environment variable <B>SANE_DE-</B>
<B>BUG_AGFAFOCUS</B> to 128 and try to regenerate the problem. Then send me a
report with the log attached.
If you encounter a SCSI bus error or trimmed and/or displaced images
please also set the environment variable <B>SANE_DEBUG_SANEI_SCSI</B> to 128
before sending me the report.
</PRE>
<H2>TODO</H2><PRE>
<B>More</B> <B>scanners?</B>
The AGFA ACS and ARCUS scanners are similar to the FOCUS scan-
ners. The driver could probably be extended to support these
scanners without too many changes. I do not have access to such
scanners, and cannot add support for it. However, if you are in
possession of such a scanner, I could be helpful in adding sup-
port for these scanners.
The AGFA HORIZON scanners are SCSI-2 scanners, and it would
probably be easier to support these scanners in a SCSI-2 compli-
ant backend.
</PRE>
<H2>SEE ALSO</H2><PRE>
<B><A HREF="sane.7.html">sane(7)</A></B>, <B><A HREF="sane-scsi.5.html">sane-scsi(5)</A></B>