Scanners not supported by SANE

Manufacturer and model

Mustek BearPaw 2448 CU Pro

Bus type

USB

Vendor ID

0x055f

Product ID

0x0408

Chipset

Controller: SQ113C (Service & Quality, www.sq.com.tw)
- probably contains embeded 8032 or something like this.
Memory: HY57V161610 - Hynix 1Mx16 synchronous? DRAM
A/D: Holtek HT82V36 - one channel(enough for CIS) A/D with serial
configuration iface
   http://www.holtek.com.tw/pdf/computer/82v36.pdf
W27C520 - 64k EEPROM, so no need for firmware upload it seems.
AIC1563CS - DC/DC converter probably for higher voltage generation
L6219 - well known stepper motor controller.

Comments

Maybe this scanner will be supported by the Mustek USB2 backend later.

Similar to the Mustek BearPaw 2448TA Pro, but uses CIS instead of CCD.

On the case of the scanner the following is written: "BearPaw 2448CU Pro MODEL NUMBER: BP 2400CU Plus"

Output of /proc/bus/usb/devices or sane-find-scanner -v -v

T:  Bus=01 Lev=01 Prnt=01 Port=00 Cnt=01 Dev#=  3 Spd=12  MxCh= 0
D:  Ver= 2.00 Cls=00(>ifc ) Sub=00 Prot=00 MxPS=64 #Cfgs=  1
P:  Vendor=055f ProdID=0408 Rev= 1.00
S:  Manufacturer=Hewlett-Packard.        
S:  Product=USB2.0 Scanner            
C:* #Ifs= 1 Cfg#= 1 Atr=80 MxPwr=500mA
I:  If#= 0 Alt= 0 #EPs= 3 Cls=ff(vend.) Sub=ff Prot=ff Driver=(none)
E:  Ad=01(O) Atr=02(Bulk) MxPS=  64 Ivl=0ms
E:  Ad=82(I) Atr=02(Bulk) MxPS=  64 Ivl=0ms
E:  Ad=83(I) Atr=03(Int.) MxPS=   1 Ivl=3ms

T:  Bus=01 Lev=01 Prnt=01 Port=00 Cnt=01 Dev#=  7 Spd=480 MxCh= 0
D:  Ver= 2.00 Cls=00(>ifc ) Sub=00 Prot=00 MxPS=64 #Cfgs=  1
P:  Vendor=055f ProdID=0408 Rev= 1.00
S:  Manufacturer=Hewlett-Packard.
S:  Product=USB2.0 Scanner
C:* #Ifs= 1 Cfg#= 1 Atr=80 MxPwr=500mA
I:  If#= 0 Alt= 0 #EPs= 3 Cls=ff(vend.) Sub=ff Prot=ff Driver=(none)
E:  Ad=01(O) Atr=02(Bulk) MxPS= 512 Ivl=0ms
E:  Ad=82(I) Atr=02(Bulk) MxPS= 512 Ivl=0ms
E:  Ad=83(I) Atr=03(Int.) MxPS=   1 Ivl=500us

<device descriptor of 0x055f/0x0408 at 004:002 (Hewlett-Packard.         
hp scanjet                )>
bLength               18
bDescriptorType       1
bcdUSB                2.00
bDeviceClass          0
bDeviceSubClass       0
bDeviceProtocol       0
bMaxPacketSize0       64
idVendor              0x055F
idProduct             0x0408
bcdDevice             1.00
iManufacturer         1 (Hewlett-Packard.        )
iProduct              2 (hp scanjet                )
iSerialNumber         0 ()
bNumConfigurations    1
 <configuration 0>
 bLength              9
 bDescriptorType      2
 wTotalLength         39
 bNumInterfaces       1
 bConfigurationValue  1
 iConfiguration       0 ()
 bmAttributes         192 (Self-powered)
 MaxPower             100 mA
  <interface 0>
   <altsetting 0>
   bLength            9
   bDescriptorType    4
   bInterfaceNumber   0
   bAlternateSetting  0
   bNumEndpoints      3
   bInterfaceClass    255
   bInterfaceSubClass 255
   bInterfaceProtocol 255
   iInterface         0 ()
    <endpoint 0>
    bLength           7
    bDescriptorType   5
    bEndpointAddress  0x01 (out 0x01)
    bmAttributes      2 (bulk)
    wMaxPacketSize    512
    bInterval         0 ms
    bRefresh          0
    bSynchAddress     0
    <endpoint 1>
    bLength           7
    bDescriptorType   5
    bEndpointAddress  0x82 (in 0x02)
    bmAttributes      2 (bulk)
    wMaxPacketSize    512
    bInterval         0 ms
    bRefresh          0
    bSynchAddress     0
    <endpoint 2>
    bLength           7
    bDescriptorType   5
    bEndpointAddress  0x83 (in 0x03)
    bmAttributes      3 (interrupt)
    wMaxPacketSize    1
    bInterval         3 ms
    bRefresh          0
    bSynchAddress     0

<trying to find out which USB chip is used>
    checking for GT-6801 ...
    this is not a GT-6801 (bDeviceClass = 0)
    checking for GT-6816 ...
    this is not a GT-6816 (bcdUSB = 0x200)
    checking for MA-1017 ...
    this is not a MA-1017 (bDeviceClass = 0, bInterfaceClass = 255)
    checking for MA-1015 ...
    this is not a MA-1015 (bDeviceClass = 0)
    checking for MA-1509 ...
    this is not a MA-1509 (bDeviceClass = 0)
    checking for LM983[1,2,3] ...
    this is not a LM983x (bcdUSB = 0x200)
    checking for GL646 ...
    this is not a GL646 (bDeviceClass = 0, bInterfaceClass = 255)
    checking for GL646_HP ...
    this is not a GL646_HP (bDeviceClass = 0, bInterfaceClass = 255)
    checking for GL660+GL646 ...
    this is not a GL660+GL646 (bDeviceClass = 0, bInterfaceClass = 255)
    checking for GL841 ...
    this is not a GL841 (bDeviceClass = 0, bInterfaceClass = 255)
    checking for ICM532B ...
  check 1, this is not a ICM532B (bDeviceClass = 0, bInterfaceClass = 255)
<Couldn't determine the type of the USB chip>

found USB scanner (vendor=0x055f [Hewlett-Packard.        ], product=0x0408 [hp scanjet                ]) at libusb:004:002
    

Want to add or correct information?

If anything is wrong or missing on this page please file a bug report or use the the form for adding an unsupported device.

If you own an unsupported scanner, please send as much information as possible. Especially the output of sane-find-scanner -v -v and/or cat /proc/scsi/scsi (for SCSI scanners) or cat /proc/bus/usb/devices (for USB scanners) can help. If you dare to open the scanner, have a look at the text that's printed on the chips. That may help to identify the chipset. If you know that the scanner is similar to another one (e.g. supported by the same Windows driver), please also mention this fact.

Information for Manufacturers

Are you a manufacturer or vendor of scanners and one of your scanners is not supported by SANE yet? In this case please have a look at our information for manufacturers.

Links


SANE homepage
Contact

$Date$ $Author$