diff --git a/unsupported/edt-900c.html b/unsupported/edt-900c.html new file mode 100644 index 00000000..f11fdf7b --- /dev/null +++ b/unsupported/edt-900c.html @@ -0,0 +1,198 @@ + + + +
++ EDT (Electronic Document Technology) BizCardReader 900C +
++ USB +
++ 0x0A53 +
++ 0x5001 +
++ sq113c +
++ (from jnewlin AT medmate.com:) Very small, card scanner. Will scan up to 4 inch card. USB 2.0 scanner. + 24 bit color, 256 grayscale or black and white. Scanner is a 2 inches + deep and 1.5 inches tall. The driver for Microsoft Windows uses + usbscan.sys and a TWAIN DLL. Manufacturer does not have any Linux drivers + available. +
++<device descriptor of 0x0a53/0x5001 at 001:060 (PANDP Co., Ltd. USB2.0 Scanner )> +bLength 18 +bDescriptorType 1 +bcdUSB 2.00 +bDeviceClass 0 +bDeviceSubClass 0 +bDeviceProtocol 0 +bMaxPacketSize0 64 +idVendor 0x0A53 +idProduct 0x5001 +bcdDevice 1.00 +iManufacturer 1 (PANDP Co., Ltd. ) +iProduct 2 (USB2.0 Scanner ) +iSerialNumber 0 () +bNumConfigurations 1 + <configuration 0> + bLength 9 + bDescriptorType 2 + wTotalLength 39 + bNumInterfaces 1 + bConfigurationValue 1 + iConfiguration 0 () + bmAttributes 128 () + MaxPower 500 mA + <interface 0> + <altsetting 0> + bLength 9 + bDescriptorType 4 + bInterfaceNumber 0 + bAlternateSetting 0 + bNumEndpoints 3 + bInterfaceClass 255 + bInterfaceSubClass 255 + bInterfaceProtocol 255 + iInterface 0 () + <endpoint 0> + bLength 7 + bDescriptorType 5 + bEndpointAddress 0x01 (out 0x01) + bmAttributes 2 (bulk) + wMaxPacketSize 512 + bInterval 0 ms + bRefresh 0 + bSynchAddress 0 + <endpoint 1> + bLength 7 + bDescriptorType 5 + bEndpointAddress 0x82 (in 0x02) + bmAttributes 2 (bulk) + wMaxPacketSize 512 + bInterval 0 ms + bRefresh 0 + bSynchAddress 0 + <endpoint 2> + bLength 7 + bDescriptorType 5 + bEndpointAddress 0x83 (in 0x03) + bmAttributes 3 (interrupt) + wMaxPacketSize 1 + bInterval 3 ms + bRefresh 0 + bSynchAddress 0 + +<trying to find out which USB chip is used> + checking for GT-6801 ... + this is not a GT-6801 (bDeviceClass = 0) + checking for GT-6816 ... + this is not a GT-6816 (bcdUSB = 0x200) + checking for GT-8911 ... + this is not a GT-8911 (check 2, bcdUSB = 0x200) + checking for MA-1017 ... + this is not a MA-1017 (bDeviceClass = 0, bInterfaceClass = 255) + checking for MA-1015 ... + this is not a MA-1015 (bDeviceClass = 0) + checking for MA-1509 ... + this is not a MA-1509 (bDeviceClass = 0) + checking for LM983[1,2,3] ... + this is not a LM983x (bcdUSB = 0x200) + checking for GL646 ... + this is not a GL646 (bDeviceClass = 0, bInterfaceClass = 255) + checking for GL646_HP ... + this is not a GL646_HP (bDeviceClass = 0, bInterfaceClass = 255) + checking for GL660+GL646 ... + this is not a GL660+GL646 (bDeviceClass = 0, bInterfaceClass = 255) + checking for GL841 ... + this is not a GL841 (bDeviceClass = 0, bInterfaceClass = 255) + checking for ICM532B ... + this is not a ICM532B (check 1, bDeviceClass = 0, bInterfaceClass = 255) + checking for PV8630/LM9830 ... + this is not a PV8630/LM9830 (bcdUSB = 0x200) + checking for M011 ... + this is not a M011 (bDeviceClass = 0) + checking for RTS8822L-01H ... + this is not a RTS8822L-01H (bEndpointAddress = 0x1, bmAttributes = 0x2, wMaxPacketSize = 0x200, bInterval = 0x0) + checking for rts8858c ... + this is not a rts8858c (bcdUSB = 0x200) + checking for SQ113 ... + Sensor not home? (0x28) +<Couldn't determine the type of the USB chip (result from sane-backends 1.0.18)> ++ +
+ If anything is wrong or missing on this page please file a bug report + or use the the + form for adding an unsupported device. +
++ If you own an unsupported scanner, please send as much information as + possible. Especially the output of sane-find-scanner -v -v + and/or cat /proc/scsi/scsi (for SCSI scanners) or cat + /proc/bus/usb/devices (for USB scanners) can help. If you dare to + open the scanner, have a look at the text that's printed on the + chips. That may help to identify the chipset. If you know that the + scanner is similar to another one (e.g. supported by the same Windows + driver), please also mention this fact. +
+ ++ Are you a manufacturer or vendor of scanners and one of your scanners is + not supported by SANE yet? In this case please have a look at our information for manufacturers. +
+ +
+ SANE homepage
+ Contact
+
+ $Date$ $Author$ +
+ + + diff --git a/unsupported/plustek-opticpro-st64plus.html b/unsupported/plustek-opticpro-st64plus.html new file mode 100644 index 00000000..b64809c4 --- /dev/null +++ b/unsupported/plustek-opticpro-st64plus.html @@ -0,0 +1,196 @@ + + + + ++ Plustek OpticPro ST64+ +
++ USB +
++ 0x07b3 +
++ 0x0c03 +
++ GL843 +
++ Chipset is visible without opening the scanner. +
++<device descriptor of 0x07b3/0x0c03 at 005:003> +bLength 18 +bDescriptorType 1 +bcdUSB 2.00 +bDeviceClass 255 +bDeviceSubClass 255 +bDeviceProtocol 255 +bMaxPacketSize0 64 +idVendor 0x07B3 +idProduct 0x0C03 +bcdDevice 4.00 +iManufacturer 10 ((null)) +iProduct 11 ((null)) +iSerialNumber 0 () +bNumConfigurations 1 + <configuration 0> + bLength 9 + bDescriptorType 2 + wTotalLength 39 + bNumInterfaces 1 + bConfigurationValue 1 + iConfiguration 0 () + bmAttributes 192 (Self-powered) + MaxPower 10 mA + <interface 0> + <altsetting 0> + bLength 9 + bDescriptorType 4 + bInterfaceNumber 0 + bAlternateSetting 0 + bNumEndpoints 3 + bInterfaceClass 255 + bInterfaceSubClass 255 + bInterfaceProtocol 255 + iInterface 0 () + <endpoint 0> + bLength 7 + bDescriptorType 5 + bEndpointAddress 0x81 (in 0x01) + bmAttributes 2 (bulk) + wMaxPacketSize 512 + bInterval 0 ms + bRefresh 0 + bSynchAddress 0 + <endpoint 1> + bLength 7 + bDescriptorType 5 + bEndpointAddress 0x02 (out 0x02) + bmAttributes 2 (bulk) + wMaxPacketSize 512 + bInterval 0 ms + bRefresh 0 + bSynchAddress 0 + <endpoint 2> + bLength 7 + bDescriptorType 5 + bEndpointAddress 0x83 (in 0x03) + bmAttributes 3 (interrupt) + wMaxPacketSize 1 + bInterval 8 ms + bRefresh 0 + bSynchAddress 0 + +<trying to find out which USB chip is used> + checking for GT-6801 ... + this is not a GT-6801 (bcdUSB = 0x200) + checking for GT-6816 ... + this is not a GT-6816 (bDeviceClass = 255, bInterfaceClass = 255) + checking for GT-8911 ... + this is not a GT-8911 (check 1, bDeviceClass = 255, bInterfaceClass = 255) + checking for MA-1017 ... + this is not a MA-1017 (bDeviceClass = 255, bInterfaceClass = 255) + checking for MA-1015 ... + this is not a MA-1015 (bcdUSB = 0x200) + checking for MA-1509 ... + this is not a MA-1509 (bcdUSB = 0x200) + checking for LM983[1,2,3] ... + this is not a LM983x (bcdUSB = 0x200) + checking for GL646 ... + this is not a GL646 (bDeviceClass = 255, bInterfaceClass = 255) + checking for GL646_HP ... + this is not a GL646_HP (bcdUSB = 0x200) + checking for GL660+GL646 ... + this is not a GL660+GL646 (bDeviceClass = 255, bInterfaceClass = 255) + checking for GL841 ... + Couldn't set configuration: could not set config 1: Operation not permitted +<This USB chip looks like a GL841?> + +found USB scanner (vendor=0x07b3, product=0x0c03, chip=GL841?) at libusb:005:003 + + +T: Bus=05 Lev=01 Prnt=01 Port=02 Cnt=01 Dev#= 3 Spd=480 MxCh= 0 +D: Ver= 2.00 Cls=ff(vend.) Sub=ff Prot=ff MxPS=64 #Cfgs= 1 +P: Vendor=07b3 ProdID=0c03 Rev= 4.00 +S: Manufacturer=PLUSTEK INC +S: Product=USB2.0 SCANNER +C:* #Ifs= 1 Cfg#= 1 Atr=c0 MxPwr= 10mA +I: If#= 0 Alt= 0 #EPs= 3 Cls=ff(vend.) Sub=ff Prot=ff Driver=(none) +E: Ad=81(I) Atr=02(Bulk) MxPS= 512 Ivl=0ms +E: Ad=02(O) Atr=02(Bulk) MxPS= 512 Ivl=0ms +E: Ad=83(I) Atr=03(Int.) MxPS= 1 Ivl=16ms ++ +
+ If anything is wrong or missing on this page please file a bug report + or use the the + form for adding an unsupported device. +
++ If you own an unsupported scanner, please send as much information as + possible. Especially the output of sane-find-scanner -v -v + and/or cat /proc/scsi/scsi (for SCSI scanners) or cat + /proc/bus/usb/devices (for USB scanners) can help. If you dare to + open the scanner, have a look at the text that's printed on the + chips. That may help to identify the chipset. If you know that the + scanner is similar to another one (e.g. supported by the same Windows + driver), please also mention this fact. +
+ ++ Are you a manufacturer or vendor of scanners and one of your scanners is + not supported by SANE yet? In this case please have a look at our information for manufacturers. +
+ +
+ SANE homepage
+ Contact
+
+ $Date$ $Author$ +
+ + +