kopia lustrzana https://gitlab.com/sane-project/website
Merge branch 'fix-removed-frontend-man' into 'master'
Restore deleted frontend manuals to 2bb9b9ce4
See merge request sane-project/website!6
master
commit
5c8d8c2861
|
@ -0,0 +1,183 @@
|
|||
<HTML>
|
||||
<HEAD>
|
||||
<TITLE>scanadf.1</TITLE>
|
||||
</HEAD>
|
||||
<BODY BGCOLOR=#FFFFFF TEXT=#000000><H1 ALIGN=CENTER><IMG SRC="../images/sane.png" HEIGHT=117 WIDTH=346></H1>
|
||||
<H1>scanadf.1</H1>
|
||||
<HR>
|
||||
<PRE>
|
||||
<!-- Manpage converted by man2html 3.0.1 -->
|
||||
<B><A HREF="scanadf.1.html">scanadf(1)</A></B> <B><A HREF="scanadf.1.html">scanadf(1)</A></B>
|
||||
|
||||
|
||||
</PRE>
|
||||
<H2>NAME</H2><PRE>
|
||||
scanadf - acquire multiple images from a scanner equipped with an ADF
|
||||
|
||||
|
||||
</PRE>
|
||||
<H2>SYNOPSIS</H2><PRE>
|
||||
<B>scanadf</B> [<B>-d</B>|<B>--device-name</B> <I>dev</I>] [<B>-h</B>|<B>--help</B>] [<B>-L</B>|<B>--list-devices</B>]
|
||||
[<B>-v</B>|<B>--verbose</B>] [<B>-V</B>|<B>--version</B>] [<B>-o</B>|<B>--output-file</B> <I>name</I>] [<B>-S</B>|<B>--scan-script</B>
|
||||
<I>name</I>] [<B>-s</B>|<B>--start-count</B> <I>num</I>] [<B>-e</B>|<B>--end-count</B> <I>num</I>] [<B>-r</B>|<B>--raw</B>] [<I>device-</I>
|
||||
<I>specific-options</I>]
|
||||
|
||||
|
||||
</PRE>
|
||||
<H2>DESCRIPTION</H2><PRE>
|
||||
<B>scanadf</B> is a command-line interface to control image acquisition
|
||||
devices which are capable of returning a series of images (e.g. a scan-
|
||||
ner with an automatic document feeder (ADF)). The device is controlled
|
||||
via command-line options. After command-line processing, <B>scanadf</B> nor-
|
||||
mally proceeds to acquire a series of images until the device returns
|
||||
the <B>SANE_STATUS_NO_DOCS</B> status code.
|
||||
|
||||
The images are written to output files, specified by the <B>--output-file</B>
|
||||
option. These files are typically written in one of the PNM (portable
|
||||
aNyMaP) formats (PBM for black-and-white images, PGM for grayscale
|
||||
images, and PPM for color images). Several optional frame formats
|
||||
(SANE_FRAME_JPEG, SANE_FRAME_G31D, SANE_FRAME_G32D, SANE_FRAME_G42D,
|
||||
and SANE_FRAME_TEXT) are supported. In each case, the data is written
|
||||
out to the output file as-is without a header. Unrecognized frame for-
|
||||
mats are handled in the same way, although a warning message is printed
|
||||
in verbose mode.
|
||||
|
||||
Typically, the optional frame formats are used in conjunction with a
|
||||
scan script (specified by the <B>--scanscript</B> option) which is invoked for
|
||||
each acquired image. The script is provided with a series of environ-
|
||||
ment variables which describe the parameters and format of the image
|
||||
file.
|
||||
|
||||
<B>scanadf</B> accesses image acquisition devices through the SANE (Scanner
|
||||
Access Now Easy) interface and can thus support any device for which
|
||||
there exists a SANE backend (try "apropos sane-" to get a list of
|
||||
available backends).
|
||||
|
||||
|
||||
</PRE>
|
||||
<H2>OPTIONS</H2><PRE>
|
||||
The <B>-d</B> or <B>--device-name</B> options must be followed by a SANE device-name.
|
||||
A (partial) list of available devices can be obtained with the <B>--list-</B>
|
||||
<B>devices</B> option (see below). If no device-name is specified explicitly,
|
||||
<B>scanadf</B> will attempt to open the first available device.
|
||||
|
||||
The <B>-h</B> or <B>--help</B> options request help information. The information is
|
||||
printed on standard output and in this case, no attempt will be made to
|
||||
acquire an image.
|
||||
|
||||
The <B>-L</B> or <B>--list-devices</B> option requests a (partial) list of devices
|
||||
that are available. The list is not complete since some devices may be
|
||||
available, but are not listed in any of the configuration files (which
|
||||
are typically stored in directory /usr/local/etc/sane.d). This is par-
|
||||
ticularly the case when accessing scanners through the network. If a
|
||||
device is not listed in a configuration file, the only way to access it
|
||||
is by its full device name. You may need to consult your system admin-
|
||||
istrator to find out the names of such devices.
|
||||
|
||||
The <B>-v</B> or <B>--verbose</B> options increase the verbosity of the operation of
|
||||
<B>scanadf.</B> The option may be specified repeatedly, each time increasing
|
||||
the verbosity level.
|
||||
|
||||
The <B>-V</B> or <B>--version</B> option requests that <B>scanadf</B> print the program and
|
||||
package name, as well as the version number of the SANE distribution
|
||||
that it came with.
|
||||
|
||||
The <B>-o</B> or <B>--output-file</B> option specifies a format string used to gener-
|
||||
ate the name of file to write the image data to. You can use %d
|
||||
replacement in the output file name; this will be replaced with the
|
||||
current page number. The default format string is image-%04d.
|
||||
|
||||
The <B>-S</B> or <B>--scan-script</B> option specifies the name of script to run
|
||||
after each scanned image is acquired. The script receives the name of
|
||||
the image output file as its first and only command line argument.
|
||||
Additionally the scan script can reference the following environment
|
||||
variables to get information about the parameters of the image.
|
||||
|
||||
<B>SCAN_RES</B> - the image resolution (in DPI)
|
||||
<B>SCAN_WIDTH</B> - the image width (in pixels)
|
||||
<B>SCAN_HEIGHT</B> - the image height (in pixels)
|
||||
<B>SCAN_DEPTH</B> - the image bit-depth (in bits)
|
||||
<B>SCAN_FORMAT</B> - a string representing the image format (e.g. gray,
|
||||
g42d, text, etc)
|
||||
<B>SCAN_FORMAT_ID</B> - the numeric image format identifier
|
||||
|
||||
The <B>-s</B> or <B>--start-count</B> option specifies the page number of first
|
||||
scanned image.
|
||||
|
||||
The <B>-e</B> or <B>--end-count</B> option specifies the last page number to scan.
|
||||
Using this option, you can request a specific number of pages to be
|
||||
scanned, rather than scanning until there are no more images available.
|
||||
|
||||
The <B>-r</B> or <B>--raw</B> option specifies that the raw image data be written to
|
||||
the output file as-is without interpretation. This disables the writ-
|
||||
ing of the PNM header for basic frame types. This feature is usually
|
||||
used in conjunction with the <B>--scan-script</B> option where the scan script
|
||||
uses the environment variables to understand the format and parameters
|
||||
of the image and converts the file to a more useful format. NOTE: With
|
||||
support for the optional frame types and the default handling of unrec-
|
||||
ognized frametypes, this option becomes less and less useful.
|
||||
|
||||
As you might imagine, much of the power of <B>scanadf</B> comes from the fact
|
||||
that it can control any SANE backend. Thus, the exact set of command-
|
||||
line options depends on the capabilities of the selected device. To
|
||||
see the options for a device named <I>dev</I>, invoke <B>scanadf</B> via a command-
|
||||
line of the form:
|
||||
|
||||
scanadf --help --device <I>dev</I>
|
||||
|
||||
The documentation for the device-specific options printed by <B>--help</B> is
|
||||
explained in the manual page for <B>scanimage.</B>
|
||||
|
||||
|
||||
</PRE>
|
||||
<H2>FILES</H2><PRE>
|
||||
<I>/usr/local/etc/sane.d</I>
|
||||
This directory holds various configuration files. For details,
|
||||
please refer to the manual pages listed below.
|
||||
|
||||
|
||||
</PRE>
|
||||
<H2>SEE ALSO</H2><PRE>
|
||||
<B><A HREF="scanimage.1.html">scanimage(1)</A></B>, <B><A HREF="xscanimage.1.html">xscanimage(1)</A></B>, <B><A HREF="sane.7.html">sane(7)</A></B>
|
||||
|
||||
|
||||
</PRE>
|
||||
<H2>AUTHOR</H2><PRE>
|
||||
scanadf is an adaptation by Tom Martone of scanimage by David Mos-
|
||||
berger, Andreas Beck, and Gordon Matzigkeit following closely the
|
||||
features of bnhscan by Sean Reifschneider of tummy.com, ltd.
|
||||
|
||||
|
||||
</PRE>
|
||||
<H2>BUGS</H2><PRE>
|
||||
Please send reports to <I>sane-devel@alioth-lists.debian.net</I>.
|
||||
|
||||
This program relies on the backend to return the <B>SANE_STATUS_NO_DOCS</B>
|
||||
status code when the automatic document feeder is out of paper. Use of
|
||||
this program with backends that do not support ADFs (e.g. flatbed scan-
|
||||
ners) will likely result in repeated scans of the same document. In
|
||||
this case, it is essential to use the start-count and end-count to con-
|
||||
trol the number of images acquired.
|
||||
|
||||
Only a subset of the SANE backends support feeders and return SANE_STA-
|
||||
TUS_NO_DOCS appropriately. Backends which are known to work at this
|
||||
time are:
|
||||
|
||||
<B>sane-bh</B> - Bell+Howell Copiscan II series scanners.
|
||||
<B>sane-hp</B> - Hewlett Packard scanners. A patch to the sane-hp
|
||||
backend is necessary. The --scantype=ADF option must be speci-
|
||||
fied (earlier versions of the backend used the --scan-from-adf
|
||||
option, instead).
|
||||
<B>sane-umax</B> - UMAX scanners. Support exists in build 12 and
|
||||
later. The --source="Automatic Document Feeder" option must be
|
||||
specified.
|
||||
|
||||
15 Sep 1999 <B><A HREF="scanadf.1.html">scanadf(1)</A></B>
|
||||
</PRE>
|
||||
<HR>
|
||||
<ADDRESS>
|
||||
Man(1) output converted with
|
||||
<a href="http://www.oac.uci.edu/indiv/ehood/man2html.html">man2html</a>
|
||||
</ADDRESS>
|
||||
</BODY>
|
||||
</HTML>
|
|
@ -0,0 +1,58 @@
|
|||
<HTML>
|
||||
<HEAD>
|
||||
<TITLE>xcam.1</TITLE>
|
||||
</HEAD>
|
||||
<BODY BGCOLOR=#FFFFFF TEXT=#000000><H1 ALIGN=CENTER><IMG SRC="../images/sane.png" HEIGHT=117 WIDTH=346></H1>
|
||||
<H1>xcam.1</H1>
|
||||
<HR>
|
||||
<PRE>
|
||||
<!-- Manpage converted by man2html 3.0.1 -->
|
||||
<B><A HREF="xcam.1.html">xcam(1)</A></B> <B><A HREF="xcam.1.html">xcam(1)</A></B>
|
||||
|
||||
|
||||
</PRE>
|
||||
<H2>NAME</H2><PRE>
|
||||
xcam - a graphical camera frontend for SANE
|
||||
|
||||
|
||||
</PRE>
|
||||
<H2>SYNOPSIS</H2><PRE>
|
||||
<B>xcam</B>
|
||||
|
||||
|
||||
</PRE>
|
||||
<H2>DESCRIPTION</H2><PRE>
|
||||
Should be straightforward to use. Just be sure to use a very recent
|
||||
version of GTK.
|
||||
|
||||
|
||||
</PRE>
|
||||
<H2>FILES</H2><PRE>
|
||||
<I>$HOME/.sane/xcam/devicename.rc</I>
|
||||
For each device, there is one rc-file that holds the saved set-
|
||||
tings for that particular device. Normally, this file should
|
||||
not be manipulated directly. Instead, the user should use the
|
||||
<B>xcam</B> interface to select appropriate values and then save the
|
||||
device settings using the "Preferences->Save as default set-
|
||||
tings" menubar entry.
|
||||
|
||||
|
||||
</PRE>
|
||||
<H2>SEE ALSO</H2><PRE>
|
||||
<B><A HREF="sane.7.html">sane(7)</A></B>, <B><A HREF="xscanimage.1.html">xscanimage(1)</A></B>, <B><A HREF="scanimage.1.html">scanimage(1)</A></B>, <B><A HREF="sane-dll.5.html">sane-dll(5)</A></B> and the backend man-
|
||||
pages
|
||||
|
||||
|
||||
</PRE>
|
||||
<H2>AUTHOR</H2><PRE>
|
||||
David Mosberger-Tang
|
||||
|
||||
24 Jun 2000 <B><A HREF="xcam.1.html">xcam(1)</A></B>
|
||||
</PRE>
|
||||
<HR>
|
||||
<ADDRESS>
|
||||
Man(1) output converted with
|
||||
<a href="http://www.oac.uci.edu/indiv/ehood/man2html.html">man2html</a>
|
||||
</ADDRESS>
|
||||
</BODY>
|
||||
</HTML>
|
|
@ -0,0 +1,169 @@
|
|||
<HTML>
|
||||
<HEAD>
|
||||
<TITLE>xscanimage.1</TITLE>
|
||||
</HEAD>
|
||||
<BODY BGCOLOR=#FFFFFF TEXT=#000000><H1 ALIGN=CENTER><IMG SRC="../images/sane.png" HEIGHT=117 WIDTH=346></H1>
|
||||
<H1>xscanimage.1</H1>
|
||||
<HR>
|
||||
<PRE>
|
||||
<!-- Manpage converted by man2html 3.0.1 -->
|
||||
<B><A HREF="xscanimage.1.html">xscanimage(1)</A></B> <B><A HREF="xscanimage.1.html">xscanimage(1)</A></B>
|
||||
|
||||
|
||||
</PRE>
|
||||
<H2>NAME</H2><PRE>
|
||||
xscanimage - scan an image
|
||||
|
||||
|
||||
</PRE>
|
||||
<H2>SYNOPSIS</H2><PRE>
|
||||
<B>xscanimage</B> [<B>--version</B>|<B>-V</B>] [<B>--help</B>|<B>-h</B>] [<B>--display</B> <I>d</I>] [<B>--no-xshm</B>]
|
||||
[<B>--sync</B>] [<I>devicename</I>]
|
||||
|
||||
|
||||
</PRE>
|
||||
<H2>DESCRIPTION</H2><PRE>
|
||||
<B>xscanimage</B> provides a graphical user-interface to control an image
|
||||
acquisition device such as a flatbed scanner or a camera. It allows
|
||||
previewing and scanning invidual images and can be invoked either
|
||||
directly from the command-line or through The GIMP image manipulation
|
||||
program. In the former case, <B>xscanimage</B> acts as a stand-alone program
|
||||
that saves acquired images in a suitable PNM format (PBM for black-and-
|
||||
white images, PGM for grayscale images, and PPM for color images). In
|
||||
the latter case, the images are directly passed to The GIMP for further
|
||||
processing.
|
||||
|
||||
<B>xscanimage</B> accesses image acquisition devices through the SANE (Scanner
|
||||
Access Now Easy) interface. The list of available devices depends on
|
||||
installed hardware and configuration. When invoked without an explicit
|
||||
devicename argument, <B>xscanimage</B> presents a dialog listing of all known
|
||||
and available devices. If the environment variable SANE_DEFAULT_DEVICE
|
||||
is set to the devicename, the device is preselected in the dialog. To
|
||||
access an available device that is not known to the system, the device-
|
||||
name must be specified explicitly. The format of devicename is backend-
|
||||
name:devicefile (e.g. umax:/dev/sga).
|
||||
|
||||
|
||||
</PRE>
|
||||
<H2>RUNNING UNDER THE GIMP</H2><PRE>
|
||||
To run <B>xscanimage</B> under the <B><A HREF="gimp.1.html">gimp(1)</A></B>, simply copy it to one of the
|
||||
<B><A HREF="gimp.1.html">gimp(1)</A></B> plug-ins directories. If you want to conserve disk-space, you
|
||||
can create a symlink instead. For example, for gimp-1.0.x the command
|
||||
|
||||
ln -s /usr/local/bin/xscanimage ~/.gimp/plug-ins/
|
||||
|
||||
and for gimp-1.2.x the command
|
||||
|
||||
ln -s /usr/local/bin/xscanimage ~/.gimp-1.2/plug-ins/
|
||||
|
||||
adds a symlink for the <B>xscanimage</B> binary to the user's plug-ins direc-
|
||||
tory. After creating this symlink, <B>xscanimage</B> will be queried by
|
||||
<B><A HREF="gimp.1.html">gimp(1)</A></B> the next time it's invoked. From then on, <B>xscanimage</B> can be
|
||||
invoked through "File->Acquire->Xscanimage->Device dialog..." menu
|
||||
entry.
|
||||
|
||||
You'll also find that the "File->Acquire->Xscanimage" menu contains
|
||||
short-cuts to the SANE devices that were available at the time <B>xscanim-</B>
|
||||
<B>age</B> was queried. For example, the first PNM pseudo-device is typically
|
||||
available as the short-cut "File->Acquire->Xscanimage->pnm:0". Note
|
||||
that <B><A HREF="gimp.1.html">gimp(1)</A></B> caches these short-cuts in ~/.gimp/pluginrc. Thus, when
|
||||
the list of available devices changes (e.g., a new scanner is
|
||||
installed), then it is typically desirable to rebuild this cache. To
|
||||
do this, you can either <B><A HREF="touch.1.html">touch(1)</A></B> the <B>xscanimage</B> binary (e.g., "touch
|
||||
/usr/local/bin/xscanimage") or delete the plug-ins cache (e.g., "rm
|
||||
~/.gimp/plug-ins"). Either way, invoking <B><A HREF="gimp.1.html">gimp(1)</A></B> afterwards will cause
|
||||
the pluginrc to be rebuilt.
|
||||
|
||||
|
||||
</PRE>
|
||||
<H2>OPTIONS</H2><PRE>
|
||||
If the <B>--version</B> <B>(-V)</B> option is given, <B>xscanimage</B> will output its ver-
|
||||
sion number.
|
||||
|
||||
The <B>--help</B> <B>(-h)</B> flag prints a short summary of options.
|
||||
|
||||
The <B>--display</B> flag selects the X11 display used to present the graphi-
|
||||
cal user-interface (see <B><A HREF="X.1.html">X(1)</A></B> for details).
|
||||
|
||||
The <B>--no-xshm</B> flag requests not to use shared memory images. Shared
|
||||
memory images usually enhance performance but cause problems with some
|
||||
buggy X11 servers. Unless your X11 server dies when running this pro-
|
||||
gram, there is no need or advantage to specify this flag.
|
||||
|
||||
The <B>--sync</B> flag requests a synchronous connection with the X11 server.
|
||||
This is for debugging purposes only.
|
||||
|
||||
|
||||
</PRE>
|
||||
<H2>ENVIRONMENT</H2><PRE>
|
||||
<B>SANE_DEFAULT_DEVICE</B>
|
||||
The default device-name. Example:
|
||||
SANE_DEFAULT_DEVICE="hp:/dev/scanner".
|
||||
|
||||
<B>SANE_DEBUG_XSCANIMAGE</B>
|
||||
This environment variable controls the debug level xscanimage.
|
||||
Higher debug levels increase the verbosity of the output.
|
||||
|
||||
Value Descsription
|
||||
0 print fatal errors
|
||||
1 print errors
|
||||
2 print warnings
|
||||
3 print information messages
|
||||
4 print everything
|
||||
|
||||
Example:
|
||||
SANE_DEBUG_XSCANIMAGE=3
|
||||
|
||||
|
||||
</PRE>
|
||||
<H2>FILES</H2><PRE>
|
||||
<I>$HOME/.sane/xscanimage/xscanimage.rc</I>
|
||||
This files holds the user preferences. Normally, this file
|
||||
should not be manipulated directly. Instead, the user should
|
||||
customize the program through the "Preferences" dialog.
|
||||
|
||||
<I>$HOME/.sane/xscanimage/devicename.rc</I>
|
||||
For each device, there is one rc-file that holds the saved set-
|
||||
tings for that particular device. Normally, this file should
|
||||
not be manipulated directly. Instead, the user should use the
|
||||
<B>xscanimage</B> interface to select appropriate values and then save
|
||||
the device settings using the "Preferences->Save Device Set-
|
||||
tings" menubar entry.
|
||||
|
||||
<I>$HOME/.sane/preview-devicename.ppm</I>
|
||||
After acquiring a preview, <B>xscanimage</B> normally saves the preview
|
||||
image in this device-specific file. Thus, next time the program
|
||||
is started up, the program can present the old preview image.
|
||||
This feature can be turned off through the "Preferences->Preview
|
||||
Options..." dialog.
|
||||
|
||||
<I>/usr/local/share/sane-style.rc</I>
|
||||
This system-wide file controls the aspects of the user-interface
|
||||
such as colors and fonts. It is a GTK style file and provides
|
||||
fine control over the visual aspects of the user-interface.
|
||||
|
||||
<I>$HOME/.sane/sane-style.rc</I>
|
||||
This file serves the same purpose as the system-wide style file.
|
||||
If present, it takes precedence over the system wide style file.
|
||||
|
||||
|
||||
</PRE>
|
||||
<H2>SEE ALSO</H2><PRE>
|
||||
<B><A HREF="sane.7.html">sane(7)</A></B>, <B><A HREF="gimp.1.html">gimp(1)</A></B>, <B><A HREF="xcam.1.html">xcam(1)</A></B>, <B><A HREF="scanimage.1.html">scanimage(1)</A></B>, <B><A HREF="scanadf.1.html">scanadf(1)</A></B>, <B><A HREF="sane-scsi.5.html">sane-scsi(5)</A></B>,
|
||||
<B><A HREF="sane-dll.5.html">sane-dll(5)</A></B>, <B><A HREF="sane-net.5.html">sane-net(5)</A></B>, sane-"backendname"(5)
|
||||
|
||||
|
||||
</PRE>
|
||||
<H2>AUTHOR</H2><PRE>
|
||||
Tristan Tarrant, Andreas Beck, David Mosberger, and Henning Meier-
|
||||
Geinitz
|
||||
|
||||
1 Feb 2003 <B><A HREF="xscanimage.1.html">xscanimage(1)</A></B>
|
||||
</PRE>
|
||||
<HR>
|
||||
<ADDRESS>
|
||||
Man(1) output converted with
|
||||
<a href="http://www.oac.uci.edu/indiv/ehood/man2html.html">man2html</a>
|
||||
</ADDRESS>
|
||||
</BODY>
|
||||
</HTML>
|