kopia lustrzana https://gitlab.com/sane-project/website
69 wiersze
3.2 KiB
HTML
69 wiersze
3.2 KiB
HTML
|
<!-- received="Fri Apr 23 00:59:10 1999 PDT" -->
|
|||
|
<!-- sent="Fri, 23 Apr 1999 09:59:11 +0200 (MET DST)" -->
|
|||
|
<!-- name="Ole W. Saastad" -->
|
|||
|
<!-- email="o.w.saastad@kjemi.uio.no" -->
|
|||
|
<!-- subject="Scanning and interpolation" -->
|
|||
|
<!-- id="" -->
|
|||
|
<!-- inreplyto="" -->
|
|||
|
<title>sane-devel: Scanning and interpolation</title>
|
|||
|
<h1>Scanning and interpolation</h1>
|
|||
|
<b>Ole W. Saastad</b> (<a href="mailto:o.w.saastad@kjemi.uio.no"><i>o.w.saastad@kjemi.uio.no</i></a>)<br>
|
|||
|
<i>Fri, 23 Apr 1999 09:59:11 +0200 (MET DST)</i>
|
|||
|
<p>
|
|||
|
<ul>
|
|||
|
<li> <b>Messages sorted by:</b> <a href="date.html#321">[ date ]</a><a href="index.html#321">[ thread ]</a><a href="subject.html#321">[ subject ]</a><a href="author.html#321">[ author ]</a>
|
|||
|
<!-- next="start" -->
|
|||
|
<li> <b>Next message:</b> <a href="0322.html">becka@rz.uni-duesseldorf.de: "Re: Scanner internals and SANE backends"</a>
|
|||
|
<li> <b>Previous message:</b> <a href="0320.html">Alex Belits: "Re: Star Office and scanner"</a>
|
|||
|
<!-- nextthread="start" -->
|
|||
|
<!-- reply="end" -->
|
|||
|
</ul>
|
|||
|
<!-- body="start" -->
|
|||
|
I have played some time with scanning software (AGFA and HP) and <br>
|
|||
|
especially tested the best way of scanning, 100, 200, 300 dpi, and <br>
|
|||
|
1200 dpi (interpolated). The file size differ a lot but they are reduced <br>
|
|||
|
afterwards to equal with jpg compression. Apparently it looks like the <br>
|
|||
|
interpolation routines (HP) do a good job. It looks like the picture <br>
|
|||
|
scanned with 1200 dpi have higher resolution than the one scanned with <br>
|
|||
|
only 300 dpi, which is the optical resolution of the scanner.<br>
|
|||
|
The best result is obtained by scanning in 1200 dpi and reducing the <br>
|
|||
|
file with jpg compression, even though I had expected scanning in 300<br>
|
|||
|
dpi to as good as 1200 dpi.<br>
|
|||
|
<p>
|
|||
|
SANE does no interpolation and will only deliver the optical resolution <br>
|
|||
|
of the scanner. Is the apparent enhancement of the picture only an<br>
|
|||
|
illusion?<br>
|
|||
|
It seems that the resolution is higher also when blowing the picture up<br>
|
|||
|
to see each individual pixel. Even if the illusion is only apparent to the<br>
|
|||
|
eye it could in many cases make the pictures look better.<br>
|
|||
|
<p>
|
|||
|
It might be a good idea to introduce interpolation into SANE ? Is the<br>
|
|||
|
algorithms behind this free ? Or are these routines known for all ?<br>
|
|||
|
How is the interpolation done ? Close to the hardware or on the picture<br>
|
|||
|
after scanning ? E.g. could it be done in GIMP ? - Or must it be a driver<br>
|
|||
|
routine ?<br>
|
|||
|
<p>
|
|||
|
None of the companies that make scanners have introduced Linux software<br>
|
|||
|
yet. Agfa has stated that it newer will. The other say they will wait<br>
|
|||
|
and see. With 10 million Linux users growing 25% a annum Linux support<br>
|
|||
|
will emerge.<br>
|
|||
|
<p>
|
|||
|
<p>
|
|||
|
Ole W Saastad <br>
|
|||
|
<p>
|
|||
|
<p>
|
|||
|
<pre>
|
|||
|
--
|
|||
|
Source code, list archive, and docs: <a href="http://www.mostang.com/sane/">http://www.mostang.com/sane/</a>
|
|||
|
To unsubscribe: echo unsubscribe sane-devel | mail <a href="mailto:majordomo@mostang.com">majordomo@mostang.com</a>
|
|||
|
</pre>
|
|||
|
<!-- body="end" -->
|
|||
|
<p>
|
|||
|
<ul>
|
|||
|
<!-- next="start" -->
|
|||
|
<li> <b>Next message:</b> <a href="0322.html">becka@rz.uni-duesseldorf.de: "Re: Scanner internals and SANE backends"</a>
|
|||
|
<li> <b>Previous message:</b> <a href="0320.html">Alex Belits: "Re: Star Office and scanner"</a>
|
|||
|
<!-- nextthread="start" -->
|
|||
|
<!-- reply="end" -->
|
|||
|
</ul>
|