| .TH sane\-artec 5 "11 Jul 2008" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
 | |
| .IX sane\-artec
 | |
| 
 | |
| .SH NAME
 | |
| sane\-artec \- SANE backend for Artec flatbed scanners
 | |
| 
 | |
| .SH DESCRIPTION
 | |
| The
 | |
| .B sane\-artec
 | |
| library implements a SANE (Scanner Access Now Easy) backend
 | |
| that provides access to Artec/Ultima SCSI flatbed scanners.  At present,
 | |
| the following scanners are known to work at least partially with this backend:
 | |
| .PP
 | |
| .RS
 | |
| * Artec A6000C
 | |
| .br
 | |
| * Artec A6000C PLUS
 | |
| .br
 | |
| * Artec ViewStation AT3
 | |
| .br
 | |
| * BlackWidow BW4800SP (rebadged Artec AT3)
 | |
| .br
 | |
| * Artec ViewStation AT6
 | |
| .br
 | |
| * Artec ViewStation AT12
 | |
| .br
 | |
| * Artec AM12S
 | |
| .br
 | |
| * Plustek 19200S (rebadged Artec AM12S)
 | |
| .RE
 | |
| .PP
 | |
| Although this manual page is generally updated with each release,
 | |
| up-to-date information on new releases and extraneous helpful hints
 | |
| are available from the backend homepage:
 | |
| .br
 | |
| .br
 | |
| .RS
 | |
| .B http://www4.infi.net/~cpinkham/sane/
 | |
| .RE
 | |
| 
 | |
| .SH DOCUMENTATION
 | |
| 
 | |
| 
 | |
| .SH CONFIGURATION
 | |
| 
 | |
| The contents of the
 | |
| .I artec.conf
 | |
| file are a list of device names that
 | |
| correspond to Artec scanners.  Empty lines and lines starting with a
 | |
| hash mark (#) are ignored.  See
 | |
| .I sane\-scsi(5)
 | |
| on details of what constitutes a valid device name.
 | |
| 
 | |
| Sample file:
 | |
| .br
 | |
| .br
 | |
| .nf
 | |
| # artec.conf
 | |
| #
 | |
| # this is a comment.
 | |
| #
 | |
| # this line says search for any SCSI devices which are scanners and have
 | |
| #     a vendor string of 'ULTIMA'
 | |
| scsi ULTIMA
 | |
| #
 | |
| # the next line forces the backend to assume the next scanner found has
 | |
| #     the specified vendor string (useful for testing rebadged models).
 | |
| vendor ULTIMA
 | |
| #
 | |
| # the next line forces the backend to assume the next scanner found has
 | |
| #     the specified model string (useful for testing rebadged models).
 | |
| model AT3
 | |
| #
 | |
| # now a line that actually specifies a device.  The backend is going to
 | |
| #     assume this is an Artec/Ultima AT3 because we forced the vendor and
 | |
| #     model above.
 | |
| /dev/scanner
 | |
| #
 | |
| # once we hit a scanner device line, the forced vendor and model
 | |
| # string are
 | |
| #     'forgotten', so the vendor and model for this next device will be
 | |
| #     determined from the result of a SCSI inquiry.
 | |
| /dev/sge
 | |
| #
 | |
| .fi
 | |
| 
 | |
| .SH SCSI ADAPTER TIPS
 | |
| 
 | |
| Some Artec scanners come with an included SCSI adapter.  If your scanner came
 | |
| with a DTC ISA scsi cards, you can probably use it with recent (>= 2.2.0)
 | |
| kernels using the generic NCR5380 support.  You must pass the following
 | |
| boot argument to the kernel: "dtc3181e=0x2c0,0"
 | |
| .br
 | |
| I do not have any information on the PCI SCSI adapter included with some
 | |
| newer Artec scanners.
 | |
| 
 | |
| .SH FILES
 | |
| .TP
 | |
| .I @CONFIGDIR@/artec.conf
 | |
| The backend configuration file (see also description of
 | |
| .B SANE_CONFIG_DIR
 | |
| below).
 | |
| .TP
 | |
| .I @LIBDIR@/libsane\-artec.a
 | |
| The static library implementing this backend.
 | |
| .TP
 | |
| .I @LIBDIR@/libsane\-artec.so
 | |
| The shared library implementing this backend (present on systems that
 | |
| support dynamic loading).
 | |
| .SH ENVIRONMENT
 | |
| .TP
 | |
| .B SANE_CONFIG_DIR
 | |
| This environment variable specifies the list of directories that may
 | |
| contain the configuration file.  Under UNIX, the directories are
 | |
| separated by a colon (`:'), under OS/2, they are separated by a semi-
 | |
| colon (`;').  If this variable is not set, the configuration file is
 | |
| searched in two default directories: first, the current working direc-
 | |
| tory (".") and then in @CONFIGDIR@.  If the value of the
 | |
| environment variable ends with the directory separator character, then
 | |
| the default directories are searched after the explicitly specified
 | |
| directories.  For example, setting
 | |
| .B SANE_CONFIG_DIR
 | |
| to "/tmp/config:" would result in directories "tmp/config", ".", and
 | |
| "@CONFIGDIR@" being searched (in this order).
 | |
| .TP
 | |
| .B SANE_DEBUG_ARTEC
 | |
| If the library was compiled with debug support enabled, this environment
 | |
| variable controls the debug level for this backend. E.g., a value of 128
 | |
| requests all debug output to be printed. Smaller levels reduce verbosity:
 | |
| SANE_DEBUG_ARTEC values
 | |
| 
 | |
| .ft CR
 | |
| .nf
 | |
| Number  Remark
 | |
| \
 | |
|  0       print important errors
 | |
|  1       print errors
 | |
|  2       print sense
 | |
|  3       print warnings
 | |
|  4       print scanner-inquiry
 | |
|  5       print information
 | |
|  6       print less important information
 | |
|  7       print major called procedures
 | |
|  8       print all called procedures
 | |
|  9       print procedure info/data messages
 | |
|  10      print called sane\-init-routines
 | |
|  11      print called sane\-procedures
 | |
|  12      print sane infos
 | |
|  13      print sane option-control messages
 | |
| \
 | |
|  50      print verbose data/debug messages
 | |
| \
 | |
|  == 100  print software RGB calibration data
 | |
|  == 101  print raw data from scanner to artec.data.raw file
 | |
| \
 | |
|  == 128  print out all messages
 | |
| .fi
 | |
| .ft R
 | |
| .PP
 | |
| Example:
 | |
| export SANE_DEBUG_ARTEC=13
 | |
| 
 | |
| .SH BUGS
 | |
| 
 | |
| Known bugs in this release: A6000C+ users with firmware v1.92 or
 | |
| earlier have problems with the backend, the cause has not been determined.
 | |
| Sometimes the backend is not particularly robust, you can possibly lock up
 | |
| the SCSI bus (and/or machine) by not having patience enough when scanning.
 | |
| 3-channel gamma correction is not implemented and single-channel gamma
 | |
| correction is not totally working on models other than the AT3.
 | |
| 
 | |
| .SH "SEE ALSO"
 | |
| 
 | |
| sane(7), sane\-scsi(5)
 | |
| 
 | |
| .SH AUTHOR
 | |
| 
 | |
| Chris Pinkham (cpinkham@corp.infi.net)
 |