kopia lustrzana https://gitlab.com/sane-project/backends
135 wiersze
4.1 KiB
Groff
135 wiersze
4.1 KiB
Groff
.TH sane-ma1509 5 "24 Feb 2003" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
|
|
.IX sane-ma1509
|
|
.SH NAME
|
|
sane-ma1509 \- SANE backend for Mustek BearPaw 1200F USB scanner
|
|
.SH DESCRIPTION
|
|
The
|
|
.B sane-ma1509
|
|
library implements a SANE (Scanner Access Now Easy) backend that provides
|
|
access to the Mustek BearPaw 1200F USB flatbed scanner. This scanner is based
|
|
on the MA-1509 chipset. Other scanners that use this chip (if they exist) may
|
|
also work.
|
|
.PP
|
|
This backend is ALPHA software. Be careful and remove the power plug
|
|
immediately if your hear unusual noises.
|
|
.PP
|
|
More details can be found on the ma1509 backend homepage
|
|
.IR http://www.meier-geinitz.de/sane/ma1509-backend/ .
|
|
.PP
|
|
Other Mustek USB scanners are supported by the gt68xx, mustek_usb and the
|
|
plustek backends. See
|
|
.BR sane-mustek_usb (5),
|
|
.BR sane-gt68xx (5)
|
|
and
|
|
.BR sane-plustek (5)
|
|
for details.
|
|
.PP
|
|
This backend can only work with scanners that are already detected by the
|
|
operating system. See
|
|
.BR sane-usb (5)
|
|
for details.
|
|
.PP
|
|
If you own a scanner other than the Mustek BearPaw 1200F that works with this
|
|
backend, please let me know this by sending the scanner's exact model name and
|
|
the USB vendor and device ids (e.g. from
|
|
.I /proc/bus/usb/devices
|
|
or syslog) to me.
|
|
|
|
.SH "DEVICE NAMES"
|
|
This backend expects device names of the form:
|
|
.PP
|
|
.RS
|
|
.I special
|
|
.RE
|
|
.PP
|
|
Where
|
|
.I special
|
|
is a path-name for the special device that corresponds to a USB scanner.
|
|
With Linux, such a device name could be
|
|
.I /dev/usb/scanner0
|
|
or
|
|
.IR libusb:001:002 ,
|
|
for example.
|
|
.PP
|
|
|
|
.SH CONFIGURATION
|
|
The contents of the
|
|
.I ma1509.conf
|
|
file is a list of options and device names that correspond to Mustek BearPaw
|
|
1200F scanners. Empty lines and lines starting with a hash mark (#) are
|
|
ignored.
|
|
.PP
|
|
Instead of using the device name, the scanner can be autodetected by
|
|
.B "usb vendor_id product_id"
|
|
statements which are already included into
|
|
.IR ma1509.conf .
|
|
This is only supported with Linux 2.4.8 and higher and all systems that
|
|
support libsub. "vendor_id" and "product_id" are hexadecimal numbers that
|
|
identify the scanner. If this doesn't work, a device name must be placed in
|
|
.I ma1509.conf
|
|
as described above.
|
|
.PP
|
|
To set the time the lamp needs for warm-up, use
|
|
.B option
|
|
.B warmup-time
|
|
in
|
|
.IR ma1509.conf .
|
|
The time is given in seconds after the option. The default is 30 seconds.
|
|
.SH FILES
|
|
.TP
|
|
.I @CONFIGDIR@/ma1509.conf
|
|
The backend configuration file (see also description of
|
|
.B SANE_CONFIG_DIR
|
|
below).
|
|
.TP
|
|
.I @LIBDIR@/libsane-ma1509.a
|
|
The static library implementing this backend.
|
|
.TP
|
|
.I @LIBDIR@/libsane-ma1509.so
|
|
The shared library implementing this backend (present on systems that
|
|
support dynamic loading).
|
|
.SH ENVIRONMENT
|
|
.TP
|
|
.B SANE_CONFIG_DIR
|
|
This environment variable specifies the list of directories that may
|
|
contain the configuration file. Under UNIX, the directories are
|
|
separated by a colon (`:'), under OS/2, they are separated by a
|
|
semi-colon (`;'). If this variable is not set, the configuration file
|
|
is searched in two default directories: first, the current working
|
|
directory (".") and then in @CONFIGDIR@. If the value of the
|
|
environment variable ends with the directory separator character, then
|
|
the default directories are searched after the explicitly specified
|
|
directories. For example, setting
|
|
.B SANE_CONFIG_DIR
|
|
to "/tmp/config:" would result in directories "tmp/config", ".", and
|
|
"@CONFIGDIR@" being searched (in this order).
|
|
.TP
|
|
.B SANE_DEBUG_MA1509
|
|
If the library was compiled with debug support enabled, this
|
|
environment variable controls the debug level for this backend. Higher
|
|
debug levels increase the verbosity of the output.
|
|
|
|
.SH "SEE ALSO"
|
|
.BR sane (7),
|
|
.BR sane-usb (5),
|
|
.BR sane-gt68xx (5),
|
|
.BR sane-plustek (5),
|
|
.BR sane-mustek_usb (5),
|
|
.BR sane-mustek (5),
|
|
.BR sane-mustek_pp (5),
|
|
.br
|
|
.I http://www.meier-geinitz.de/sane/ma1509-backend/
|
|
|
|
.SH AUTHOR
|
|
Henning Meier-Geinitz <henning@meier-geinitz.de>
|
|
|
|
.SH BUGS
|
|
Resolutions higher than 600 dpi don't work
|
|
.br
|
|
Transparency adapter and automatic document feeder is not supported yet
|
|
.br
|
|
No support for "high-speed" mode (jpeg)
|
|
.PP
|
|
More detailed bug information is available at the MA-1509 backend homepage
|
|
.IR http://www.meier-geinitz.de/sane/ma1509-backend/ .
|