.\" .IX sane-lexmark
|
||
.TH "sane-lexmark" "5" "16 April 2007" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
|
||
.SH "NAME"
|
||
sane\-lexmark \- SANE backend for Lexmark X1100/X1200 Series scanners
|
||
.SH "DESCRIPTION"
|
||
The
|
||
.B sane\-lexmark
|
||
library implements a SANE (Scanner Access Now Easy) backend that
|
||
provides access to the scanner part of Lexmark X1100/X1200 AIOs. This backend
|
||
should be considered
|
||
.B beta\-quality
|
||
software!
|
||
.PP
|
||
The scanners that should work with this backend are:
|
||
.PP
|
||
.RS
|
||
.ft CR
|
||
.nf
|
||
Vendor Model status
|
||
\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\- \-\-\-\-\-\-\-\-\-\-\-
|
||
Lexmark X1110 untested
|
||
Lexmark X1140 untested
|
||
Lexmark X1150 good
|
||
Lexmark X1170 good
|
||
Lexmark X1180 good
|
||
Lexmark X1185 complete
|
||
Lexmark X12xx good in USB1.1,
|
||
not fully tested in USB2.0
|
||
Dell A920 good
|
||
.fi
|
||
.ft R
|
||
.RE
|
||
|
||
The options the backend supports can either be selected through
|
||
command line options to programs like scanimage or through GUI
|
||
elements in xscanimage or xsane.
|
||
|
||
.br
|
||
If you have any strange behavior, please report to the backend
|
||
maintainer or to the SANE mailing list.
|
||
|
||
Valid command line options and their syntax can be listed by using
|
||
.RS
|
||
scanimage \-\-help \-d lexmark:usb:<usb port>
|
||
.RE
|
||
|
||
.TP
|
||
.B Scan Mode Options
|
||
|
||
.TP
|
||
.B \-\-mode
|
||
selects the basic mode of operation of the scanner valid choices are
|
||
.I R Color ,
|
||
.I Gray
|
||
and
|
||
.I Lineart
|
||
The default mode is Color. The Lineart mode is black and white only (1 bit).
|
||
Grayscale will produce 256 levels of gray (8 bits). Color mode allows for over
|
||
16 million different colors produced from 24 bits of color information.
|
||
|
||
.TP
|
||
.B \-\-resolution
|
||
selects the resolution for a scan. The horizontal and vertical resolutions are set
|
||
by the value of this option. The scanner is capable of the following resolutions for the specified option value:
|
||
.PP
|
||
.RS
|
||
.ft CR
|
||
.nf
|
||
Value Hor. Resolution Vert. Resolution
|
||
\-\-\-\-\- \-\-\-\-\-\-\-\-\-\-\-\-\-\-\- \-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-
|
||
75 75dpi 75dpi
|
||
150 150dpi 150dpi
|
||
300 300dpi 300dpi
|
||
600 600dpi 600dpi
|
||
1200 600dpi 1200dpi (only for X11xx models with 'B2' sensor)
|
||
.fi
|
||
.ft R
|
||
.RE
|
||
|
||
.TP
|
||
.B \-\-preview
|
||
requests a preview scan. The resolution used for that scan is 75 dpi
|
||
and the scan area and the scan mode are as specified through their options,
|
||
or the default if not specified. The default value for preview mode is "no".
|
||
|
||
.TP
|
||
.B \-\-threshold
|
||
selects the minimum\-brightness to get a white point. The threshold is only used with Lineart mode scans.
|
||
It is specified as a percentage in the range 0..100% (in steps of 1).
|
||
The default value of the threshold option is 50.
|
||
|
||
|
||
.SH "CONFIGURATION FILE"
|
||
The configuration file @CONFIGDIR@/lexmark.conf contains only the usb device id (eg usb 0x043d 0x007c).
|
||
|
||
|
||
.SH "FILES"
|
||
.TP
|
||
.I @LIBDIR@/libsane\-lexmark.a
|
||
The static library implementing this backend.
|
||
.TP
|
||
.I @LIBDIR@/libsane\-lexmark.so
|
||
The shared library implementing this backend (present on systems that
|
||
support dynamic loading).
|
||
|
||
|
||
.SH "ENVIRONMENT"
|
||
.TP
|
||
.B SANE_DEBUG_LEXMARK
|
||
.B SANE_DEBUG_LEXMARK_LOW
|
||
If the library was compiled with debug support enabled, this
|
||
environment variable controls the debug level for this backend. E.g.,
|
||
a value of 255 requests all debug output to be printed. Smaller levels
|
||
reduce verbosity.
|
||
|
||
|
||
.SH "LIMITATIONS"
|
||
The windows TWAIN driver has many more options than this SANE
|
||
backend. However they are only software adjustments. This backend only
|
||
implements what the scanner can support. For instance, shading correction
|
||
(vertical stripes due to sensor variation across its width) is done in
|
||
software. Head park position is also detected by software.
|
||
The data compression isn't supported for the X1200 serie on USB 1.1,
|
||
leading to slow scans.
|
||
|
||
.SH "BUGS"
|
||
.br
|
||
No bugs currently known.
|
||
|
||
|
||
|
||
.SH "SEE ALSO"
|
||
sane\-scsi(5), scanimage(1), xscanimage(1), xsane(1), sane(7)
|
||
|
||
|
||
.SH "AUTHOR"
|
||
.TP
|
||
The backend was originaly written by Fred Odendaal.
|
||
.I http://ca.geocities.com/freshshelf@rogers.com/
|
||
.TP
|
||
The new version is currently developped by St<EFBFBD>phane Voltz.
|
||
.I http://stef.dev.free.fr/sane/lexmark
|
||
.SH "CREDITS"
|
||
.TP
|
||
Many thanks go to:
|
||
Julien Furgerot who lend me a Dell A920.
|
||
Robert Price, Dani Ele and Dalai Felinto for the time they spent recording
|
||