sane-project-backends/backend/umax_pp.conf

66 wiersze
1.8 KiB
Plaintext

# For documentation see sane-umax_pp(5)
# GLOBAL #
# size (in bytes) of scan buffer (default: 2 megabyte)
option buffer 2097152
# DEVICES #
# specify the port your scanner is connected to.
#
# the value 'auto' will make the backend find the correct value
# by itself, it will scan ppdev, ppi device, then hardware address
# 'safe-auto' will do the same but wn't do direct hardware access
# on linux systems, you may provide the device name of the ppdev character
# device : /dev/parport0, /dev/parport1, ......
#
# on *BSD, you may provide the device name of the ppi device: /dev/ppi0,
# /dev/ppi1, ...
#
# Possible hardware addresses are 0x378 (lp0)
# 0x278 (lp2) and 0x3c8 (lp1)
#
# default is ppdev since major use of the backend is for linux
port /dev/parport0
# the following options are local to this scanner
# brightness for red channel, if not given, will be automatically computed
# must be between 0 and 15
#option red-brightness 8
# brightness for green channel, if not given, will be automatically computed
# must be between 0 and 15
#option green-brightness 4
# brightness for blue channel, if not given, will be automatically computed
# must be between 0 and 15
#option blue-brightness 8
# contrast for red channel, if not given, will default to 0
# must be between 0 and 15
#option red-contrast 2
# contrast for green channel, if not given, will default to 0
# must be between 0 and 15
#option green-contrast 1
# contrast for blue channel, if not given, will default to 0
# must be between 0 and 15
#option blue-contrast 1
#
#
# model number
#
# valid values are 610, 1220, 1600 and 2000
#
# by default, no model, we rely on autodetection
# in case you have black or 'inverted' scans,
# you may prevent detection by providing the
# model number
#option astra 1220